PROPANE/LP GAS RESIDENTIAL HEATERS
SPECIFICATIONS
Btu (Variable) | 15,000/30,000 |
Type Gas | Propane/LP Only |
Ignition | Piezo |
Pressure Regulator Setting | 8" W.C. |
Inlet Gas Pressure (in. of water) * |
|
Maximum | 14" |
Minimum | 11" |
Dimensions, Inches (H x W x D) |
|
Heater | 23.75 x 25.9 x 8.5 |
Carton | 25.8 x 28.7 x 10.1 |
Weight (pounds) |
|
Heater | 29 |
Shipping | 35 |
* For purposes of input adjustment |
|
TECHNICAL
SERVICE
You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at
You can also visit DESA International’s technical service web site at www.desatech.com.
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burner(s) will have delayed ignition
•heater will not produce specified heat
•propane/LP gas supply may be low
When Gas Quality Is Bad
•pilot will not stay lit
•burner(s) will produce flames and soot
•heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP supplier.
For more information, visit www.desatech.com | 22 | 107102 |