Vanguard Heating VGN30 installation manual Turn counterclockwise

Page 14
C-clockwise
C-clockwise
C-clockwise

14

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 13. If you don’t smell gas, go to the next step.

5. Press in control knob and turn counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 13).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The burner and pilot are located behind the heat shield. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to TROUBLESHOOTING, pages 17 thru

20.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see MANUAL LIGHTING PROCEDURE, page 15.

Ignitor Electrode

Thermocouple

Pilot Burner

Pilot

GRH/OV 007F

 

Figure 14 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 sec- onds, release control knob.

Note: If pilot goes out, repeat steps 3 thru 7.

8. Turn control knob counterclockwise to the LOW position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from LOW to a higher setting, press in the control knob

and turn counterclockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

!CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

Continued

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Locating Heater Installation ItemsCheck GAS Type Surface Combustible MaterialRemoving Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveLighting Instructions For Your Safety Read Before LightingOperating Heater Turn counterclockwise To Turn OFF GAS to Appliance Manual Lighting ProcedureInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Air PassagewaysCleaning From Ing statement at TopTechnical Service Service HintsParts Not Under Warranty Replacement PartsParts Under Warranty Accessories Valve GA5010ODS/Pilot Parts List KEY Part Number Description QTYPage Page Warranty Information International

VGN30 specifications

The Vanguard Heating VGN30 is a cutting-edge heating solution that has been designed to deliver exceptional performance and efficiency for residential and commercial spaces. This heating unit is known for its advanced technology, reliability, and ease of use, making it an ideal choice for consumers looking to enhance their indoor comfort.

One of the standout features of the VGN30 is its high-efficiency heating system. With a thermal efficiency rating that exceeds industry standards, this unit utilizes innovative combustion technology to maximize heat output while minimizing fuel consumption. This results in reduced energy bills and a lower environmental footprint, making it an eco-friendly choice.

The VGN30 is equipped with a robust stainless steel heat exchanger that enhances durability and ensures long-lasting performance. This material is resistant to corrosion and wear, allowing the unit to maintain peak efficiency over time. Furthermore, the heat exchanger's design promotes optimal heat transfer, ensuring that spaces are heated quickly and evenly.

User comfort and convenience are paramount in the design of the VGN30. The unit features a user-friendly digital thermostat that enables precise temperature control and allows users to program heating schedules based on their preferences. This smart technology not only enhances comfort but also contributes to energy savings.

Safety is another critical aspect of the VGN30. The unit includes multiple safety features, such as overheat protection and a flame failure cutoff system, which automatically shuts off the heating element in case of any malfunctions. This provides peace of mind for users, knowing that their heating system prioritizes safety.

Installation and maintenance are straightforward with the VGN30. The unit is designed for easy access to components, facilitating routine maintenance and ensuring that it operates efficiently throughout its lifespan. Additionally, the VGN30’s compact design allows for versatile placement in various environments, whether in a utility room or basement.

In summary, the Vanguard Heating VGN30 stands out as a reliable and efficient heating solution. Its high efficiency, durable construction, user-friendly technology, and safety features make it a top contender for anyone seeking to improve their heating system. With the VGN30, users can enjoy a warm, comfortable environment while reducing energy costs and their impact on the planet.