Vanguard Heating VGN30 installation manual Check GAS Type, Installation Items, Locating Heater

Page 5

INSTALLING TO WALL

NOTICE

A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing the heater, make sure you have the items listed below.

piping (check local codes)

test gauge connection * (see

sealant (resistant to propane gas)

 

Figure 10, page 11)

• manual shutoff valve *

• sediment trap

ground joint union

tee joint

 

 

• pipe wrench

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See ACCESSORIES, page 23.

LOCATING HEATER

This heater is designed to be mounted on a wall.

!WARNING

Maintain the minimum clearances shown in Figure 2 (page 6). If you can, provide greater clearances from floor, ceiling, and join- ing wall.

!WARNING

Never install the heater

in sleeping quarters, a mobile home, or a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

NOTICE

Do not install or operate heater in areas where impurities in the air (such as tobacco smoke) exist. Particles from these impurities may discolor walls.

Continued

5

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Locating Heater Installation ItemsCheck GAS Type Combustible Material SurfaceMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Heater Turn counterclockwise Inspecting Burner Manual Lighting ProcedureTo Turn OFF GAS to Appliance Pilot Flame PatternCorrect Burner Flame Pattern Burner Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingCabinet Air PassagewaysCleaning From Top Ing statement atService Hints Technical ServiceParts Not Under Warranty Replacement PartsParts Under Warranty Valve GA5010 AccessoriesODS/Pilot KEY Part Number Description QTY Parts ListPage Page International Warranty Information

VGN30 specifications

The Vanguard Heating VGN30 is a cutting-edge heating solution that has been designed to deliver exceptional performance and efficiency for residential and commercial spaces. This heating unit is known for its advanced technology, reliability, and ease of use, making it an ideal choice for consumers looking to enhance their indoor comfort.

One of the standout features of the VGN30 is its high-efficiency heating system. With a thermal efficiency rating that exceeds industry standards, this unit utilizes innovative combustion technology to maximize heat output while minimizing fuel consumption. This results in reduced energy bills and a lower environmental footprint, making it an eco-friendly choice.

The VGN30 is equipped with a robust stainless steel heat exchanger that enhances durability and ensures long-lasting performance. This material is resistant to corrosion and wear, allowing the unit to maintain peak efficiency over time. Furthermore, the heat exchanger's design promotes optimal heat transfer, ensuring that spaces are heated quickly and evenly.

User comfort and convenience are paramount in the design of the VGN30. The unit features a user-friendly digital thermostat that enables precise temperature control and allows users to program heating schedules based on their preferences. This smart technology not only enhances comfort but also contributes to energy savings.

Safety is another critical aspect of the VGN30. The unit includes multiple safety features, such as overheat protection and a flame failure cutoff system, which automatically shuts off the heating element in case of any malfunctions. This provides peace of mind for users, knowing that their heating system prioritizes safety.

Installation and maintenance are straightforward with the VGN30. The unit is designed for easy access to components, facilitating routine maintenance and ensuring that it operates efficiently throughout its lifespan. Additionally, the VGN30’s compact design allows for versatile placement in various environments, whether in a utility room or basement.

In summary, the Vanguard Heating VGN30 stands out as a reliable and efficient heating solution. Its high efficiency, durable construction, user-friendly technology, and safety features make it a top contender for anyone seeking to improve their heating system. With the VGN30, users can enjoy a warm, comfortable environment while reducing energy costs and their impact on the planet.