If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces a

1. Metal expanding while

1. This is common with

clicking/ticking noise

heating or contracting

most heaters. If noise is

just after burner is lit or

while cooling

excessive, contact quali-

shut off

 

fied service person

 

 

 

Heater produces un-

1.

Heater burning vapors

wanted odors

 

from paint, solvents,

 

 

glues, etc.

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Ventilate garage. Stop using odor causing prod- ucts while heater is run- ning

2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 11)

Heater shuts off in use

1.

Not enough fresh air is

(ODS operates)

 

available

 

2.

Low line pressure

 

3.

ODS/pilot is partially

 

 

clogged

1.Open window and/or door for ventilation

2.Contact local natural gas company

3.Clean ODS/pilot (see

CLEANING AND MAINTENANCE, page 17)

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in OFF

 

ing statement at

 

leaks (see CHECKING

position

 

top of page

 

GAS CONNECTIONS,

 

 

 

 

page 11)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

20

Gas odor during com-

1.

Foreign matter between

bustion

 

control valve and

 

 

burner

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Take apart gas tubing and remove foreign mat- ter

2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 11)

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Locating Heater Installation ItemsCheck GAS Type Surface Combustible MaterialInstalling Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveLighting Instructions For Your Safety Read Before LightingOperating Heater Turn counterclockwise Manual Lighting Procedure Inspecting BurnerTo Turn OFF GAS to Appliance Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting ODS/PILOT and BurnerCabinet Air PassagewaysCleaning From Ing statement at TopTechnical Service Service HintsParts Not Under Warranty Replacement PartsParts Under Warranty Accessories Valve GA5010ODS/Pilot Parts List KEY Part Number Description QTYPage Page Warranty Information International

VGN30 specifications

The Vanguard Heating VGN30 is a cutting-edge heating solution that has been designed to deliver exceptional performance and efficiency for residential and commercial spaces. This heating unit is known for its advanced technology, reliability, and ease of use, making it an ideal choice for consumers looking to enhance their indoor comfort.

One of the standout features of the VGN30 is its high-efficiency heating system. With a thermal efficiency rating that exceeds industry standards, this unit utilizes innovative combustion technology to maximize heat output while minimizing fuel consumption. This results in reduced energy bills and a lower environmental footprint, making it an eco-friendly choice.

The VGN30 is equipped with a robust stainless steel heat exchanger that enhances durability and ensures long-lasting performance. This material is resistant to corrosion and wear, allowing the unit to maintain peak efficiency over time. Furthermore, the heat exchanger's design promotes optimal heat transfer, ensuring that spaces are heated quickly and evenly.

User comfort and convenience are paramount in the design of the VGN30. The unit features a user-friendly digital thermostat that enables precise temperature control and allows users to program heating schedules based on their preferences. This smart technology not only enhances comfort but also contributes to energy savings.

Safety is another critical aspect of the VGN30. The unit includes multiple safety features, such as overheat protection and a flame failure cutoff system, which automatically shuts off the heating element in case of any malfunctions. This provides peace of mind for users, knowing that their heating system prioritizes safety.

Installation and maintenance are straightforward with the VGN30. The unit is designed for easy access to components, facilitating routine maintenance and ensuring that it operates efficiently throughout its lifespan. Additionally, the VGN30’s compact design allows for versatile placement in various environments, whether in a utility room or basement.

In summary, the Vanguard Heating VGN30 stands out as a reliable and efficient heating solution. Its high efficiency, durable construction, user-friendly technology, and safety features make it a top contender for anyone seeking to improve their heating system. With the VGN30, users can enjoy a warm, comfortable environment while reducing energy costs and their impact on the planet.