Vanguard Heating VGN30 installation manual Safety Information

Page 3

SAFETY INFORMATION

Continued

!WARNINGS Continued

1.Use only natural gas. Do not convert heater to use different fuel type.

2.If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

3.Never install the heater

in sleeping quarters, a mobile home, or a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

4.Open window or garage door to admit fresh, outside air when using heater. Open window one (1) or two (2) inches. When used without fresh, outside air, heater may give off carbon monoxide gas.

5.Never run heater in small, closed room.

6.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

7.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

8.Never place any objects on the heater.

9.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.

10.Make sure grill guard is in place before running heater.

11.Do not alter heater or its controls. Any change may create a safety hazard.

12.Do not use heater if any part of heater has been under water.

13.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.

14.Do not operate heater above elevations of 4,500 feet.

3

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DevicePiezo Ignition System Installation Items Check GAS TypeLocating Heater Combustible Material SurfaceMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Turn counterclockwise Pilot Flame Pattern Manual Lighting ProcedureInspecting Burner To Turn OFF GAS to ApplianceCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetCleaning From Top Ing statement atService Hints Technical ServiceReplacement Parts Parts Under WarrantyParts Not Under Warranty Valve GA5010 AccessoriesODS/Pilot KEY Part Number Description QTY Parts ListPage Page International Warranty Information

VGN30 specifications

The Vanguard Heating VGN30 is a cutting-edge heating solution that has been designed to deliver exceptional performance and efficiency for residential and commercial spaces. This heating unit is known for its advanced technology, reliability, and ease of use, making it an ideal choice for consumers looking to enhance their indoor comfort.

One of the standout features of the VGN30 is its high-efficiency heating system. With a thermal efficiency rating that exceeds industry standards, this unit utilizes innovative combustion technology to maximize heat output while minimizing fuel consumption. This results in reduced energy bills and a lower environmental footprint, making it an eco-friendly choice.

The VGN30 is equipped with a robust stainless steel heat exchanger that enhances durability and ensures long-lasting performance. This material is resistant to corrosion and wear, allowing the unit to maintain peak efficiency over time. Furthermore, the heat exchanger's design promotes optimal heat transfer, ensuring that spaces are heated quickly and evenly.

User comfort and convenience are paramount in the design of the VGN30. The unit features a user-friendly digital thermostat that enables precise temperature control and allows users to program heating schedules based on their preferences. This smart technology not only enhances comfort but also contributes to energy savings.

Safety is another critical aspect of the VGN30. The unit includes multiple safety features, such as overheat protection and a flame failure cutoff system, which automatically shuts off the heating element in case of any malfunctions. This provides peace of mind for users, knowing that their heating system prioritizes safety.

Installation and maintenance are straightforward with the VGN30. The unit is designed for easy access to components, facilitating routine maintenance and ensuring that it operates efficiently throughout its lifespan. Additionally, the VGN30’s compact design allows for versatile placement in various environments, whether in a utility room or basement.

In summary, the Vanguard Heating VGN30 stands out as a reliable and efficient heating solution. Its high efficiency, durable construction, user-friendly technology, and safety features make it a top contender for anyone seeking to improve their heating system. With the VGN30, users can enjoy a warm, comfortable environment while reducing energy costs and their impact on the planet.