Vanguard Heating VGN30 Inspecting Burner, To Turn OFF GAS to Appliance, Manual Lighting Procedure

Page 15

INSPECTING BURNER

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

 

to the PILOT position.

1.

Turn control knob clockwise

Clockwise

2.

Press in control knob and turn clockwise Clockwise to the OFF position.

3.

Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

 

 

MANUAL LIGHTING PROCEDURE

1.Remove front panel (see Figure 3, page 7).

2.Follow steps 1 thru 5 under LIGHTING INSTRUCTIONS, pages 13 and 14.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5.Replace front panel.

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 15 shows a correct pilot flame pattern. Figure 16 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

 

Figure 15 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 16 - Incorrect Pilot Flame Pattern

Continued 15

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DevicePiezo Ignition System Installation Items Check GAS TypeLocating Heater Combustible Material SurfaceMethods For Attaching Mounting Bracket To Wall Installing Heater to WallMounting Bracket Removing Front Panel Of HeaterAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsConnecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping System Manual Shutoff Valve Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Turn counterclockwise Pilot Flame Pattern Manual Lighting ProcedureInspecting Burner To Turn OFF GAS to ApplianceCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner CabinetCleaning From Top Ing statement atService Hints Technical ServiceReplacement Parts Parts Under WarrantyParts Not Under Warranty Valve GA5010 AccessoriesODS/Pilot KEY Part Number Description QTY Parts ListPage Page International Warranty Information