OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

When control knob is

1.

Ignitor electrode posi-

1.

Replace ignitor

pressed in and turned

 

tioned wrong

 

 

to the PILOT/IGN po-

2.

Ignitor electrode broken

2.

Replace ignitor

sition, there is no

3.

Ignitor electrode not con-

3.

Reconnect ignitor cable

spark at ODS/pilot

 

nected to ignitor cable

 

 

 

4.

Ignitor cable pinched or

4.

Free ignitor cable if

 

 

wet

 

pinched by any metal or

 

 

 

 

tubing. Keep ignitor cable

 

 

 

 

dry

 

5.

Broken ignitor cable

5.

Replace ignitor cable

 

6.

Bad piezo ignitor

6.

Replace control valve (pi-

 

 

 

 

ezo is part of control

 

 

 

 

valve)

 

 

 

 

 

When control knob is pressed in and turned to the PILOT/IGN po- sition, there is spark at ODS/pilot but no igni- tion

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not pressed in while being turned to PILOT/IGN position

3.Air in gas lines when in- stalled

4.ODS/pilot is clogged

5.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Press in control knob while turning to PILOT/ IGN position

3.Continue holding down control knob. Repeat ig- niting operation until air is removed

4.Clean ODS/pilot (see

C L E A N I N G A N D MAINTENANCE, page

16) or replace ODS/pilot assembly

5.Replace gas regulator

17

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemLocating Heater Installation ItemsCheck GAS Type Ceiling Installing Heater to WallFloor Marking Screw LocationsFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Heater Pilot Burner Patterns To Select Heating LevelInspecting Burner Manual Lighting ProcedureTo Turn OFF GAS to Appliance Pilot Flame PatternBurner Flame Pattern Cleaning and MaintenanceODS/PILOT and Burner Orifice CabinetObserved Possible Problem Cause Remedy Trouble ShootingCleaning Observed Possible Problem Cause Remedy Ing statement at Technical ServiceTop VN12Parts Not Under Warranty Parts Under WarrantyManual Shutoff Valve GA5010VN6A Parts ListVN12 Illustrated Parts BreakdownLimited Warranty Vanguard VENT-FREE Residential GAS Heaters Warranty Information