Vanguard Heating VN12, VN6A installation manual Observed Possible Problem Cause Remedy

Page 19

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Burner plaque(s) does not glow

1.Plaque damaged

2.Inlet gas pressure is too low

3.Control knob set be- tween locked positions

1.Replace burner

2.Contact local natural gas company

3.Turn control knob until it locks at desired setting

Slight smoke or odor

1. Residues from manu-

1. Problem will stop after a

during initial opera-

facturing processes

few hours of operation

tion

 

 

 

 

 

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or contracting while cooling

1.This is common with most heaters. If noise is excessive, contact quali- fied service person

!WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Heater produces un- wanted odors

1.Heater burning vapors from paint, hair spray, glues, etc.

2.Gas leak. See Warn- ing statement above

1.Ventilate room. Stop us- ing odor-causing prod- ucts while heater is run- ning

2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 10)

Heater shuts off in use (ODS operates)

1.Not enough fresh air is available

2.Low line pressure

3.ODS/pilot is partially clogged

1.Open window and/or door for ventilation

2.Contact local natural gas company

3.Clean ODS/pilot (see

CLEANING AND MAINTENANCE, page 16)

19

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationCheck GAS Type Installation ItemsLocating Heater Marking Screw Locations Installing Heater to WallCeiling FloorFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Checking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingLighting Instructions Pilot Burner Patterns To Select Heating LevelPilot Flame Pattern Manual Lighting ProcedureInspecting Burner To Turn OFF GAS to ApplianceCabinet Cleaning and MaintenanceBurner Flame Pattern ODS/PILOT and Burner OrificeObserved Possible Problem Cause Remedy Trouble ShootingCleaning Observed Possible Problem Cause Remedy VN12 Technical ServiceIng statement at TopValve GA5010 Parts Under WarrantyParts Not Under Warranty Manual ShutoffVN6A Parts ListVN12 Illustrated Parts BreakdownLimited Warranty Vanguard VENT-FREE Residential GAS Heaters Warranty Information