Vanguard Heating VN6A installation manual Technical Service, Ing statement at, Top, VN12

Page 20

TECHNICAL

SERVICE

SPECIFICATIONS

20

!WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in OFF

 

ing statement at

 

leaks (see CHECK-

position

 

top of page

 

ING GAS CONNEC-

 

 

 

 

TIONS, page 10)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during com-

1.

Foreign matter between

1.

Take apart gas tubing

bustion

 

control valve and

 

and remove foreign mat-

 

 

burner

 

ter

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

ing statement at

 

leaks (see CHECKING

 

 

top of page

 

GAS CONNECTIONS,

 

 

 

 

page 10)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

VN12

VN6A

B.T.U. (Variable)

6,000/12,000

6,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

10.5"

10.5"

Minimum

4"

4"

Dimensions, Inches (H x W x D)

 

 

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

 

 

Heater

14

13

Shipping

17

16

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemLocating Heater Installation ItemsCheck GAS Type Installing Heater to Wall CeilingFloor Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveLighting Instructions For Your Safety Read Before LightingOperating Heater Pilot To Select Heating Level Burner PatternsManual Lighting Procedure Inspecting BurnerTo Turn OFF GAS to Appliance Pilot Flame PatternCleaning and Maintenance Burner Flame PatternODS/PILOT and Burner Orifice CabinetTrouble Shooting Observed Possible Problem Cause RemedyCleaning Observed Possible Problem Cause Remedy Technical Service Ing statement atTop VN12Parts Under Warranty Parts Not Under WarrantyManual Shutoff Valve GA5010Parts List VN6AIllustrated Parts Breakdown VN12Warranty Information Limited Warranty Vanguard VENT-FREE Residential GAS Heaters