1. GENERAL SAFETY INFORMATION

1. GENERAL SAFETY INFORMATION

IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS

EXPLOSION HAZARD: DO NOT INSTALL TO A HIGH PRESSURE STEAM BOILER (greater than 15 psig). AN EXPLOSION COULD OCCUR.

EXPLOSION HAZARD. THE PRESSURE OF THE HEAT TRANSFER MEDIUM MUST BE LIMITED TO A MAXIMUM OF 30 PSIG BY AN APPROVED SAFETY OR RELIEF VALVE ON YOUR BOILER. THE TANK PRESSURE MUST BE LIMITED TO 150 PSIG MAXIMUM BY THE INSTALLATION OF A

TEMPERATURE AND PRESSURE RELIEF VALVE (INCLUDED).

SCALDING HAZARD: IF THE WATER TEMPERATURE IS OVER 120° F, HOUSEHOLD MEMBERS CAN SUFFER SERIOUS OR FATAL SCALDING AND PAINFUL AND PERMANENT INJURY.

• THE CONSUMER PRODUCTS SAFETY COMMISSION RECOMMENDS AN INITIAL SETTING OF 120° F, BUT NOTES A SLOWER RESPONSE TIME OF INFANTS, AGED, DISABLED AND OTHER PERSONS INCREASES THE HAZARD TO THEM AND MAY REQUIRE LOWER SETTINGS.

•ALWAYS CHECK THE WATER TEMPERATURE BEFORE USE, INCLUDING WASHING, BATHING OR SHOWERING.

• TEMPERATURE LIMITING VALVES ARE AVAILABLE FROM YOUR PLUMBING SUPPLIER.

SCALDING HAZARD: IF THE THERMOSTAT IS NOT WORKING PROPERLY OR IF THIS PRODUCT IS NOT INSTALLED IN ACCORDANCE WITH THE MANUAL, WATER TEMPERATURE CAN REACH EXCESSIVE LEVELS THAT MAY CAUSE SERIOUS SCALDING, EVEN IF THE TEMPERATURE SETTING IS CORRECT.

AFTER INSTALLATION AND ANY SERVICING OF THE UNIT, VERIFY THAT THE THERMOSTAT IS WORKING AND FIRMLY INSERTED IN THE THERMOSTAT WELL BY FOLLOWING THE THERMOSTAT TESTING INSTRUCTIONS IN THE MANUAL AFTER INSTALLATION AND ANY SERVICING OF THE UNIT.

SCALDING HAZARD: A CHECK VALVE MUST BE INSTALLED IN THE BOILER RETURN LINE TO PREVENT GRAVITY FLOW THROUGH THE HEAT EXCHANGER. THIS CAN CAUSE OVER HEATING AND RESULT IN SERIOUS SCALDING.

IF NOT INSTALLED BY THE BOILER MANUFACTURER, INSTALL A LOW WATER CUT-OFF OR PRESSURE REDUCING VALVES MUST BE INSTALLED ON YOUR BOILER SO THAT LEAKING FROM ANY PLUMBING FIXTURE WILL NOT RESULT IN A DRY BOILER; IF THE BOILER CONTINUES TO

FIRE, AN EXPLOSION HAZARD EXISTS.

THIS UNIT MUST BE INSTALLED AS A SEPARATE HEATING ZONE. DO NOT CONNECT THIS UNIT TO AN EXISTING HEATING ZONE OR FEED BOILER WATER DIRECTLY THROUGH THE COIL AS DANGEROUS OVER-HEATING WILL RESULT.

DO NOT DRAIN THIS APPLIANCE BEFORE SHUTTING OFF THE SUPPLY VALVE AND OPENING THE RELIEF VALVE OR ANOTHER DOWNSTREAM FIXTURE, AS IT WILL DAMAGE THIS UNIT. ALSO, MAKE SURE A VACUUM BREAKER IS IN PLACE TO AVOID DAMAGING THE LINER.

AVOID RISK OF INGESTING A TOXIC FLUID. THE HEAT TRANSFER MEDIUM SHOULD BE WATER. IF GLYCOL MUST BE USED, IT SHOULD ONLY BE USED WITH DOUBLE-WALLED HEAT EXCHANGERS.

THIS TANK, LIKE MOST TANKS UNDER PRESSURE, WILL OVER TIME CORRODE OR FAIL AND/OR Manual backgroundMAY BURST AND/OR LEAK OR FLOOD (AND IN RARE CASES EXPLODE) WHICH CAN CAUSE SERIOUS OR FATAL PERSONAL INJURY AND PROPERTY DAMAGE. TO MINIMIZE RISK, A LICENSED PROFESSIONAL MUST INSTALL AND PERIODICALLY INSPECT AND SERVICE THE UNIT. A DRIP PAN,

CONNECTED TO AN ADEQUATE DRAIN MUST BE INSTALLED IF LEAKING OR FLOODING CAN CAUSE PROPERTY DAMAGE.

AS IN ALL PLUMBING PRODUCTS AND WATER STORAGE VESSELS, BACTERIA CAN GROW IN YOUR BOILER MATE TM, ESPECIALLY DURING TIMES OF NON-USE. CONSULT YOUR LOCAL PLUMBING OFFICIAL REGARDING ANY STEPS YOU MAY WISH TO TAKE TO SAFELY DISINFECT

YOUR HOME’S PLUMBING SYSTEM.

WATER QUALITY CAN SIGNIFICANTLY INFLUENCE THE LIFE OF YOUR PRODUCT, YOU SHOULD TEST FOR CORROSIVE ELEMENTS, ACIDITY, TOTAL SOLIDS, AND OTHER RELEVANT CONTAMINANTS, INCLUDING CHLORINE AND TREAT YOUR WATER APPROPRIATELY TO INSURE

SATISFACTORY PERFORMANCE AND PREVENT PREMATURE FAILURE.

FOLLOW ALL OF THE INSTRUCTIONS AND RECOMMENDATIONS CONTAINED IN THIS MANUAL, AND THE FOLLOWING ADDITIONAL SPECIFIC WARNINGS. FAILURE TO DO SO IS UNSAFE AND CAN CAUSE SERIOUS SCALDING, EXPLOSION, SERIOUS OR FATAL PERSONAL INJURY AND

PROPERTY DAMAGE.

FAILURE TO FOLLOW THE ABOVE WARNINGS MAY RESULT IN SERIOUS OR FATAL PERSONAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE WARRANTY.

-3-

Image 3
Contents INSTALLATION, OPERATION INDIRECT-FIREDWATER HEATERS WITH TOP-MOUNTEDCOILMODELS TD-7Z MAINTENANCEREQUIRED COMPONENTS AND ACCESSORIES CHECKLIST TABLE OF CONTENTSGENERAL SAFETY INFORMATION PRE-INSTALLATIONCHECKLIST1. GENERAL SAFETY INFORMATION 2. PRE-INSTALLATIONCHECKLIST 3.REQUIRED COMPONENTS AND ACCESSORIES CHECKLIST COMPONENTS CHECKLISTTD-7Z, TD-41Z, TD-7ZDW, TD-41ZDW 3. Locating Unit 4. INSTALLATION INSTRUCTIONS FORA. General Installation Requirements 1. Do not short circuit the boilerStep 1 - Locate the BOILER MATE near boiler B. PIPINGEXTERNAL TANKLESS HEATERS INTERNAL TANKLESS COILSStep 6 - Connect boiler return pipe. Figure II. BOILER MATE - Priority WiringSEPARATE CIRCULATOR Step 5 - Connect boiler supply pipe. FigurePRIORITY W/CIRCULATORS - SCHEMATIC D. POST-INSTALLATIONand START-UPCHECKLISTTEMPERATURE ADJUSTMENT ZONE VALVES - SCHEMATICPage AND LOW PRESSURE STEAM BOILER 6. OPERATION/MAINTENANCEDESCRIPTION 7. REPLACEMENT PARTSRESIDENTIAL BOILER MATE CLASSIC TD-7Zand TD-41ZCAUSE 8. TROUBLE SHOOTING CHECKLISTPROBLEM SOLUTIONCOMMENTS 9. SERVICE RECORDSERVICE PERFORMED DATEReplacement Product Warranty LIMITED FIVE YEAR COMMERCIAL WARRANTYLIMITED FIVE YEAR TRANSFERRABLE WARRANTY Additional Warranty Limitations9040-628REV B 7/04 West Warwick, Rhode Island