Jotul GF300 DV manual Gas Supply Connection, Pilot orifice removal and replacement

Page 18

15.Install the new regulator: Be sure the new gasket is properly positioned and tighten screws securely.

16.Install the identification labels to the stove so that they can be seen by any person that may be servicing the stove. Label A: apply to back of stove.

Label B: apply to the rating plate attached to the back of the stove.

Small Valve Label: apply to valve.

17.Reassemble the stove, apply gas to the system and check for leaks using a soapy water solution.

NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

18.Correct gas pressure is essential for efficient and safe operation of this appliance. Use a manometer to check pressures as specified in the Gas Pressure section of this manual (page 19).

19.Adjust the Air Shutter. You will need to position the shutter to provide a gas/air mixture that will achieve the best flame picture with your particular installa- tion. Start with the shutter stem at the half-way position in the slot in the bottom of the stove. See figs. 22 and 25. Pushing the stem back will restrict air, while pushing it forward will open the shutter and increase air. With some experimentation, you will find the shutter position that works best for your installation.

ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE INSIDE BACK COVER OF THIS MANUAL WHEN LIGHT- ING YOUR STOVE.

Pilot Head

Orifice

Retainer

Clip

Pilot Base

Figure 26. Pilot orifice removal and replacement.

VARIABLE

REGULATOR TOWER

BE SURE TO REMOVE THE

BLACK RUBBER GASKET

FROM THE VALVE!

MAIN GAS VALVE

Apply small label.

Figure 27. Regulator assembly.

Gas Supply Connection

BLOWER NOTE: Install a 90° elbow off the valve to allow clearance for installation of the optional blower.

The gas supply line connection is made to the valve just inside the left rear leg. The gas supply line should be 3/8" npt with a 1/2" diameter supply, or the appropriate size to provide sufficient gas pressure to the valve regardless of the input setting.

The use of Flexible Gas Appliance Connectors is acceptable in many areas in the U.S. However, Canadian methods vary depending on local code.

ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR CAN-B149.

All codes require a gas shut-off valve (gas cock) and union, to be installed in the supply line, and in the same room as the appliance. This allows for the disconnection of the stove for servicing and maintenance. See fig. 28.

A T-HANDLE GAS COCK IS REQUIRED IN MASSACHUSETTS TO COMPLY WITH CODE 248CMR.

Secure all joints tightly using appropriate tools and sealing compounds. For propane units be sure to use compounds that are propane resistant. Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks.

18

Image 18
Contents Jøtul GF 300 DV Allagash Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 300 DV Direct Vent Gas HeaterGF 300 DV Specifications Suggested Tools for Installation and ServiceInput Rates Hardware Bag Contents Unpacking your stoveGlass Panel Safety Information LocationHearth Requirements Horizontal Run Alcove InstallationMinimum Clearances from the Vent Pipe to Combustibles Vertical RunVent Restriction Adjusting Exhaust Restrictor PlateVenting Requirements Exhaust RestrictorVertical Vent Termination See Fig DetailVent Windows for Natural Gas Coaxial VentVent Windows for Propane Coaxial VentCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion Horizontal Termination Snorkel TerminationsHorizontal Termination Clearance Inches 30 cm minimumFuel Conversion Mobile Home InstallationConversion Kit Contents Tools requiredBurner Orifice Fuel Conversion ProcedureBurner Plate ClearancePilot orifice removal and replacement Gas Supply ConnectionHigh Altitude Adjustment Gas PressureLeak test Remote Control Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control To adjust the air shutterLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceBurner Switch and Optional Blower Controls OperationVent System Annual CleaningGlass Care Burner and LogsetConnect power cord to outlet Optional Blower #Blower Operation Manual or Automatic ModesOptional Antique Brick Kit Replace the Top PlateGF 300 DV Illustrated Parts Breakdown Illustrated Parts Breakdown GF 300 DV AllagashGF 300 DV Allagash Parts List 220730Name of Installer Date of PurchaseLighting Instructions Control ValveJøtul ASA Jøtul North America

GF300 DV specifications

The Jotul GF300 DV represents a blend of traditional wood stove aesthetics and modern gas technology, offering an elegant solution for homeowners looking to enhance their living spaces with warmth and style. This direct vent gas stove is designed to provide a highly efficient and convenient heating option while retaining the classic visual appeal that Jotul is well-known for.

One of the main features of the Jotul GF300 DV is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of heating spaces ranging from small to medium-sized rooms effectively. The stove employs a dual burner system that ensures a consistent and powerful flame, delivering both radiant and convective heat that envelops the room in comfort.

Built with advanced technologies, the GF300 DV incorporates a modern ceramic glass front that allows for an unobstructed view of the flames, creating a mesmerizing focal point in any setting. The glass is designed to retain heat while minimizing soot build-up, ensuring that the glass remains clean and clear, and allowing for a captivating view of the fire. This model also features an adjustable flame height and heat output, giving users control over their heating needs and ambiance.

The stove's direct venting system is a standout characteristic, providing optimized safety and efficiency. It draws air for combustion from the outside, significantly improving indoor air quality by preventing drafts and eliminating the need for chimney flues. This makes the GF300 DV not only a more environmentally friendly option but also a safer alternative for homes, especially in tighter, more energy-efficient spaces.

To enhance user convenience, the Jotul GF300 DV is equipped with a programmable thermostat and remote control option. This allows homeowners to set their desired temperature and schedule heating times, resulting in energy savings and tailored comfort. Additionally, the stove's compact size and stylish design make it versatile enough to fit into various room layouts, whether as a primary heating source or as an accent piece in a cozy living room.

In summary, the Jotul GF300 DV is an ideal choice for anyone looking to merge aesthetic elegance with modern heating technology. Its combination of high efficiency, superb heat output, and user-friendly features, along with stunning visual appeal, makes it a noteworthy addition to any home.