Jotul GF300 DV manual Fuel Conversion Procedure, Burner Plate, Burner Orifice, Clearance

Page 17

Fuel Conversion Procedure

1.Turn off gas supply to stove.

2.Remove the stove Top Plate.

3.Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page 5. Carefully lift the glass panel up and out of the stove.

4.If installed, remove the Embers and Log Set using care not to damage the fragile log parts.

5.Lift out the Burner Skirt- (Part 40, fig. 52 p.28).

6.Reach under the stove and remove the Air Shutter wingnut from its stud. As you face the right side, it is the one closest to you. See fig. 22.

7.Lift out the Burner Plate: NOTE: There are no screws securing the Burner to the floor of the firebox. Pull the Air Shutter forward and lift the burner together with shutter up and out of the stove as a unit. See fig. 23.

8.Change the Main Burner Orifice. See fig. 24. Using a ½” open ended wrench or deep-well socket remove the burner orifice from its brass elbow housing and replace with the appropriate orifice supplied in the kit. While removing the orifice, use an adjustable wrench to counter-lock the orifice elbow at the back of the firebox as shown in fig. 24a.

9.Replace the Air Shutter with its gasket and push it all the way back to allow replacement of the Burner Plate. Reattach the wingnut to the shutter stem under the stove, but do not tighten. You will set its final position later.

10.Replace the Burner Plate. Engage the burner tube with the Air Shutter assembly as in fig. 25. Be sure the burner is securely engaged with the two support brackets at the front of the firebox and push the plate back toward the rear of the firebox. When correctly positioned, there will be 1/2” (13 mm) clearance between the burner plate and the front of the firebox. See fig. 25.

11 . CHANGE THE PILOT ORIFICE: From within the firebox, remove the Pilot Head by pulling it straight up from the pilot base. See fig. 26. Using the 4 mm hex key included with the kit, unscrew the pilot orifice (counter- clockwise). Replace with the appropriate orifice:

12.Tighten orifice into the base of the pilot assembly. To prevent bypass leaks, be sure the orifice is secured tightly and flush with the base. Replace pilot head by pushing it down onto the pilot base.

13.Replace the Variable Regulator. Using a Torx T-20 screwdriver, remove the three screws from the front of the valve regulator. See fig. 27.

14.Remove the Regulator Tower, Gasket, white plastic disk, and Spring. Remove the black rubber gasket from the valve. See fig. 27.

Air Shutter

Burner Plate

Figure 23. Remove the Air Shutter and Burner as a unit.

Burner Orifice

Figure 24. Change the Burner Orifice.

Figure 24a. Counter-lock the orifice elbow while removing the burner orifice.

1/2”

clearance

Figure 25. Correct Burner Position.

17

Image 17
Contents Jøtul GF 300 DV Allagash Gas Heater Welcome to Jøtul Jøtul GF 300 DV Direct Vent Gas Heater Table of ContentsInput Rates GF 300 DV SpecificationsSuggested Tools for Installation and Service Glass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Minimum Clearances from the Vent Pipe to Combustibles Alcove InstallationHorizontal Run Vertical RunVenting Requirements Adjusting Exhaust Restrictor PlateVent Restriction Exhaust RestrictorSee Fig Detail Vertical Vent TerminationCoaxial Vent Vent Windows for Natural GasCoaxial Vent Vent Windows for PropaneThese installation requirements must be followed Co-linear Vent InstallationMasonry or Prefabricated Chimney Conversion Snorkel Terminations Horizontal TerminationInches 30 cm minimum Horizontal Termination ClearanceConversion Kit Contents Mobile Home InstallationFuel Conversion Tools requiredBurner Plate Fuel Conversion ProcedureBurner Orifice ClearanceGas Supply Connection Pilot orifice removal and replacementLeak test High Altitude AdjustmentGas Pressure Optional Wall Thermostat or Remote Control Flame Appearance / Air Shutter AdjustmentRemote Control To adjust the air shutterInstall Right Log Log Set InstallationProper pilot flame appearance System CheckOperation Burner Switch and Optional Blower ControlsGlass Care Annual CleaningVent System Burner and LogsetOptional Blower # Connect power cord to outletManual or Automatic Modes Blower OperationReplace the Top Plate Optional Antique Brick KitIllustrated Parts Breakdown GF 300 DV Allagash GF 300 DV Illustrated Parts Breakdown220730 GF 300 DV Allagash Parts ListDate of Purchase Name of InstallerControl Valve Lighting InstructionsJøtul North America Jøtul ASA

GF300 DV specifications

The Jotul GF300 DV represents a blend of traditional wood stove aesthetics and modern gas technology, offering an elegant solution for homeowners looking to enhance their living spaces with warmth and style. This direct vent gas stove is designed to provide a highly efficient and convenient heating option while retaining the classic visual appeal that Jotul is well-known for.

One of the main features of the Jotul GF300 DV is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of heating spaces ranging from small to medium-sized rooms effectively. The stove employs a dual burner system that ensures a consistent and powerful flame, delivering both radiant and convective heat that envelops the room in comfort.

Built with advanced technologies, the GF300 DV incorporates a modern ceramic glass front that allows for an unobstructed view of the flames, creating a mesmerizing focal point in any setting. The glass is designed to retain heat while minimizing soot build-up, ensuring that the glass remains clean and clear, and allowing for a captivating view of the fire. This model also features an adjustable flame height and heat output, giving users control over their heating needs and ambiance.

The stove's direct venting system is a standout characteristic, providing optimized safety and efficiency. It draws air for combustion from the outside, significantly improving indoor air quality by preventing drafts and eliminating the need for chimney flues. This makes the GF300 DV not only a more environmentally friendly option but also a safer alternative for homes, especially in tighter, more energy-efficient spaces.

To enhance user convenience, the Jotul GF300 DV is equipped with a programmable thermostat and remote control option. This allows homeowners to set their desired temperature and schedule heating times, resulting in energy savings and tailored comfort. Additionally, the stove's compact size and stylish design make it versatile enough to fit into various room layouts, whether as a primary heating source or as an accent piece in a cozy living room.

In summary, the Jotul GF300 DV is an ideal choice for anyone looking to merge aesthetic elegance with modern heating technology. Its combination of high efficiency, superb heat output, and user-friendly features, along with stunning visual appeal, makes it a noteworthy addition to any home.