Jotul GF300 DV manual Unpacking your stove, Glass Panel, Hardware Bag Contents

Page 5

General Information

„THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

„The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

„This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passage- ways of the appliance be kept clean.

„THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.

„The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installa- tion. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to determine what regulations apply in your area.

„CODE COMPLIANCE : Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in this manual, defaults to local code. In the absence of local codes, the installa- tion requirements must comply with the current edition of National codes. In the U.S., these require- ments are established in the National Fuel Code, ANSI Z223.1.(NFPA 54) current edition. In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code, current edition..

„Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

„DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

„Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Glass Panel

Do not operate this appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Unpacking your stove

1.Remove the Top Plate of the stove by simply lifting it straight off of the stove body.

2.To open the firebox, disengage the two Glass Frame Latches located on top of the firebox. Pull each handle forward to clear the latch from the notch in the frame.

Glass Frame

Latch

3.Familiarize yourself with the installation require- ments specified in this manual, before beginning the installation.

Hardware Bag Contents

Fuel Conversion Kit - LP................................ 155372

Ember Bag , 4 oz. ............................................ 220702

THIS FIREPLACE IS SHIPPED FROM THE FACTORY FOR USE WITH NATURAL GAS ONLY. IF USE WITH PROPANE IS DESIRED, THE APPLIANCE MUST FIRST BE CONVERTED USING THE FUEL CONVERSION KIT PROVIDED, #155372. CONVERSION SHOULD BE MADE BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 17.

5

Image 5
Contents Jøtul GF 300 DV Allagash Gas Heater Welcome to Jøtul Jøtul GF 300 DV Direct Vent Gas Heater Table of ContentsInput Rates GF 300 DV SpecificationsSuggested Tools for Installation and Service Glass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Minimum Clearances from the Vent Pipe to Combustibles Alcove InstallationHorizontal Run Vertical RunVenting Requirements Adjusting Exhaust Restrictor PlateVent Restriction Exhaust RestrictorSee Fig Detail Vertical Vent TerminationCoaxial Vent Vent Windows for Natural GasCoaxial Vent Vent Windows for PropaneThese installation requirements must be followed Co-linear Vent InstallationMasonry or Prefabricated Chimney Conversion Snorkel Terminations Horizontal TerminationInches 30 cm minimum Horizontal Termination ClearanceConversion Kit Contents Mobile Home InstallationFuel Conversion Tools requiredBurner Plate Fuel Conversion ProcedureBurner Orifice ClearanceGas Supply Connection Pilot orifice removal and replacementLeak test High Altitude AdjustmentGas Pressure Optional Wall Thermostat or Remote Control Flame Appearance / Air Shutter AdjustmentRemote Control To adjust the air shutterInstall Right Log Log Set InstallationProper pilot flame appearance System CheckOperation Burner Switch and Optional Blower ControlsGlass Care Annual CleaningVent System Burner and LogsetOptional Blower # Connect power cord to outletManual or Automatic Modes Blower OperationReplace the Top Plate Optional Antique Brick KitIllustrated Parts Breakdown GF 300 DV Allagash GF 300 DV Illustrated Parts Breakdown220730 GF 300 DV Allagash Parts ListDate of Purchase Name of InstallerControl Valve Lighting InstructionsJøtul North America Jøtul ASA

GF300 DV specifications

The Jotul GF300 DV represents a blend of traditional wood stove aesthetics and modern gas technology, offering an elegant solution for homeowners looking to enhance their living spaces with warmth and style. This direct vent gas stove is designed to provide a highly efficient and convenient heating option while retaining the classic visual appeal that Jotul is well-known for.

One of the main features of the Jotul GF300 DV is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of heating spaces ranging from small to medium-sized rooms effectively. The stove employs a dual burner system that ensures a consistent and powerful flame, delivering both radiant and convective heat that envelops the room in comfort.

Built with advanced technologies, the GF300 DV incorporates a modern ceramic glass front that allows for an unobstructed view of the flames, creating a mesmerizing focal point in any setting. The glass is designed to retain heat while minimizing soot build-up, ensuring that the glass remains clean and clear, and allowing for a captivating view of the fire. This model also features an adjustable flame height and heat output, giving users control over their heating needs and ambiance.

The stove's direct venting system is a standout characteristic, providing optimized safety and efficiency. It draws air for combustion from the outside, significantly improving indoor air quality by preventing drafts and eliminating the need for chimney flues. This makes the GF300 DV not only a more environmentally friendly option but also a safer alternative for homes, especially in tighter, more energy-efficient spaces.

To enhance user convenience, the Jotul GF300 DV is equipped with a programmable thermostat and remote control option. This allows homeowners to set their desired temperature and schedule heating times, resulting in energy savings and tailored comfort. Additionally, the stove's compact size and stylish design make it versatile enough to fit into various room layouts, whether as a primary heating source or as an accent piece in a cozy living room.

In summary, the Jotul GF300 DV is an ideal choice for anyone looking to merge aesthetic elegance with modern heating technology. Its combination of high efficiency, superb heat output, and user-friendly features, along with stunning visual appeal, makes it a noteworthy addition to any home.