Jotul Comprehensive Guide to Remote Control and Air Shutter Adjustments

Page 20

Flame Appearance / Air Shutter Adjustment

The GF 300 DV gas stove is shipped from the factory equipped to burn Natural gas. If the stove has been converted for use with propane, the Air Shutter may require adjustment to achieve the desired flame appear- ance. Other installation related variables can also affect the flame picture. The Air Shutter may be opened or closed to provide the best flame picture for your specific installation.

Too large an air opening - the appliance will generate a flame that is blue and transparent, or an “anemic” flame.

Too small an air setting - the appliance will generate very long yellow flames resulting in soot. Sooting pro- duces black deposits on the logs, on the inside walls of the appliance, and potentially on the exterior termination cap. Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening.

To adjust the air shutter:

1.Reach under the right side of the stove and loosen the wingnut located closest to you. See fig. 30. Slide the wingnut stud forward to open the air shutter and back to provide less air. Make adjustments in small incre- ments.

2.Tighten the wingnut to secure the shutter at the desired setting.

3.Allow the stove to burn for 30 minutes on the HIGH setting, observing the flame continuously. If the flame appears weak, slow, or sooty, repeat the process described above until the flame is as desired.

WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.

Optional Wall Thermostat or Remote Control

Use only a 750 millivolt DC two-wire circuit thermostat with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat.

The thermostat should be connected to the GF 300 DV using a minimum of 16 gauge wire with a maxi- mum length of 25 feet of wire.

Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly above the ignitor button. Do not overtighten the connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Fig. 31.

For thermostatic operation, the On/Off/T-Stat switch on the back of the stove must be in the T-stat position, and the pilot light must be running, as it is the power source for the thermostat.

At the thermostat, the two wires should be con- nected to the two connection screws on the thermostat base plate per the manufacturer’s instructions.

Remote Control

When using a remote, the remote receiver should be wired to the terminal block the same way the thermo- stat would be. See the instructions above.

Follow the operating instructions included with the Remote Control unit.

CAUTION:

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER OR DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERA- TION AFTER SERVICING THE APPLIANCE.

Open Close

Figure 30.

THERMOPILE

TH

TP

TH

TP

VALVE

TERMINAL

BLOCK

ROCKER

SWITCH

ON

OFF

STAT

OPTIONAL

THERMOSTAT

or

REMOTE

CONTROL

Loosen the wingnut to adjust the air shutter.

Figure 31. Accessory wiring diagram.

20

Image 20
Contents Jøtul GF 300 DV Allagash Gas Heater Welcome to Jøtul Table of Contents Jøtul GF 300 DV Direct Vent Gas HeaterInput Rates GF 300 DV SpecificationsSuggested Tools for Installation and Service Glass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Alcove Installation Minimum Clearances from the Vent Pipe to CombustiblesHorizontal Run Vertical RunAdjusting Exhaust Restrictor Plate Venting RequirementsVent Restriction Exhaust RestrictorVertical Vent Termination See Fig DetailVent Windows for Natural Gas Coaxial VentVent Windows for Propane Coaxial VentCo-linear Vent Installation These installation requirements must be followedMasonry or Prefabricated Chimney Conversion Horizontal Termination Snorkel TerminationsHorizontal Termination Clearance Inches 30 cm minimumMobile Home Installation Conversion Kit ContentsFuel Conversion Tools requiredFuel Conversion Procedure Burner PlateBurner Orifice ClearancePilot orifice removal and replacement Gas Supply ConnectionLeak test High Altitude AdjustmentGas Pressure Flame Appearance / Air Shutter Adjustment Optional Wall Thermostat or Remote ControlRemote Control To adjust the air shutterLog Set Installation Install Right LogSystem Check Proper pilot flame appearanceBurner Switch and Optional Blower Controls OperationAnnual Cleaning Glass CareVent System Burner and LogsetConnect power cord to outlet Optional Blower #Blower Operation Manual or Automatic ModesOptional Antique Brick Kit Replace the Top PlateGF 300 DV Illustrated Parts Breakdown Illustrated Parts Breakdown GF 300 DV AllagashGF 300 DV Allagash Parts List 220730Name of Installer Date of PurchaseLighting Instructions Control ValveJøtul ASA Jøtul North America

GF300 DV specifications

The Jotul GF300 DV represents a blend of traditional wood stove aesthetics and modern gas technology, offering an elegant solution for homeowners looking to enhance their living spaces with warmth and style. This direct vent gas stove is designed to provide a highly efficient and convenient heating option while retaining the classic visual appeal that Jotul is well-known for.

One of the main features of the Jotul GF300 DV is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of heating spaces ranging from small to medium-sized rooms effectively. The stove employs a dual burner system that ensures a consistent and powerful flame, delivering both radiant and convective heat that envelops the room in comfort.

Built with advanced technologies, the GF300 DV incorporates a modern ceramic glass front that allows for an unobstructed view of the flames, creating a mesmerizing focal point in any setting. The glass is designed to retain heat while minimizing soot build-up, ensuring that the glass remains clean and clear, and allowing for a captivating view of the fire. This model also features an adjustable flame height and heat output, giving users control over their heating needs and ambiance.

The stove's direct venting system is a standout characteristic, providing optimized safety and efficiency. It draws air for combustion from the outside, significantly improving indoor air quality by preventing drafts and eliminating the need for chimney flues. This makes the GF300 DV not only a more environmentally friendly option but also a safer alternative for homes, especially in tighter, more energy-efficient spaces.

To enhance user convenience, the Jotul GF300 DV is equipped with a programmable thermostat and remote control option. This allows homeowners to set their desired temperature and schedule heating times, resulting in energy savings and tailored comfort. Additionally, the stove's compact size and stylish design make it versatile enough to fit into various room layouts, whether as a primary heating source or as an accent piece in a cozy living room.

In summary, the Jotul GF300 DV is an ideal choice for anyone looking to merge aesthetic elegance with modern heating technology. Its combination of high efficiency, superb heat output, and user-friendly features, along with stunning visual appeal, makes it a noteworthy addition to any home.