Jotul GF300 BV manual High Altitude Adjustment, Derating Procedure, Replace with #40 Orifice

Page 23

High Altitude Adjustment

Installations burning natural gas and located at altitudes from 2000 - 4500 ft. (610 M - 1370 M), require compen- sation for the thinner air (less volume of air per cubic foot). Higher altitudes affect the atmospheric pressure and heat value of gaseous fuels. The lower oxygen content in the air and the lower gas viscosity require the use of a different orifice to achieve efficient, clean combustion at the burner tube.

For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the installer must convert the unit to adjust for varying altitudes, use Jøtul High Altitude Kit, #155810-NG.

DO NOT DERATE THE BURNER FOR PROPANE.

In the U.S: THE DERATING KIT MUST BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. THE INFORMATION STICKER MUST BE COMPLETED BY THE INSTALLER AND APPLIED TO THE APPLIANCE AT THE TIME OF THE CONVERSION. THE QUALIFIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS DERATING.

In Canada: This unit has been tested for installation at high altitudes in accordance with Canadian test stan- dard CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1 AND .2 INSTALLATION CODE.

AVERTISEMENT:

Cet equipement de conversion sera installe par une agence qualkfiee de service conformenment aux instructions du fabricant et toutes exigences et codes applecables de l’autorises avoir la juridiction. Si l’informaiton dans cette Instruction n’est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut resulter le dommages causer de propriete, perte ou blessure personnelle de vie. L’agence qualifiee’ de service est esponsable de l’installation propre de cet equipement. L’installation n’est pas propre et complete jusqu’a l’operation de l’appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provisionnees avec l’equipement.

Replace with #40

orifice

Figure 43. Change the Burner Orifice.

Derating Procedure

1.Follow Steps 1-10 of the Fuel Conversion procedure outlined on pages 11 and 12.

2.Replace the original orifice with the #40 orifice in the kit.

3.Fill out the high altitude conversion label from the kit and attach to the rating plate or gas valve.

4.Reassemble the firebox components.

5.It may be necessary to adjust the air shutter on the burner tube. See AIR SHUTTER/FLAME APPEARANCE on page 16 for more details.

23

Image 23
Contents GF 300 BV Allagash Installation and Operation InstructionsWelcome to Jøtul Jøtul GF 300 BV Allagash Gas Heater Table of ContentsInput Rates Suggested Tools for Installation and ServiceGlass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Vertical Run All sides 1 25 mm Minimum Alcove DimensionsMinimum Clearances from the Vent Pipe to Combustibles Horizontal RunVent Requirements Hood When installing at an altitude above 2000’Minimum Is 7 feet Approved B-Vent ConfigurationsBurner Skirt Fuel Conversion ProcedureFuel Conversion Tools requiredBurner Orifice Burner PlateRetainer Clip Valve Pilot Base From regulator assemblyGas Supply Connection Pilot Head Regulator Tower Orifice11.0 Gas PressureLeak test Install Right Log Log Set InstallationTo adjust the air shutter Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control Remote ControlMin Installing Decorative PipeSpill Switch System CheckOperation Blocked Flue SwitchBurner and Logset Annual CleaningGlass Care Vent SystemOptional Blower # Connect power cord to the nearest outletControl Blower OperationSpeed Replace the Top Plate Optional Antique Brick KitReplace with #40 Orifice High Altitude AdjustmentDerating Procedure GF 300 BV Allagash Illustrated Parts Breakdown Accessories GF 300 BV Allagash Parts ListPurchased from Name of InstallerModel Name Serial Number Date of PurchasePush in gas control knob slightly and turn clockwise toOFF Control ValveJøtul North America October 2005 137945-CJøtul AS Box Fredrikstad Norway

GF300 BV specifications

The Jotul GF300 BV is a contemporary gas stove that epitomizes elegance and efficiency. Known for its robust construction and exceptional performance, it serves as both a reliable heating source and a stunning centerpiece in any living space. This model is particularly popular among homeowners looking to blend functionality with aesthetic appeal.

One of the standout features of the Jotul GF300 BV is its advanced heating technology. Equipped with a powerful burner system, it delivers efficient heat while maintaining low emissions. The stove has a maximum output of 30,000 BTUs, making it suitable for a variety of room sizes. This capacity not only ensures ample warmth but also contributes to a consistent and pleasant environment during colder months.

The design of the GF300 BV is particularly noteworthy, featuring a large glass front that allows for an unobstructed view of the mesmerizing flames. This design choice enhances the ambiance of any room, transforming a simple heating appliance into a focal point. The stove also includes an adjustable flame height feature, allowing users to customize the intensity of the fire according to their preference.

In terms of efficiency, the Jotul GF300 BV is a leader in its class. It boasts an impressive efficiency rating, which translates to lower energy costs for homeowners. Additionally, the unit is designed to work seamlessly with modern home ventilation systems, ensuring optimal performance without compromising air quality.

Another significant characteristic of the Jotul GF300 BV is its versatility. It is available in a variety of finishes and styles, allowing it to complement diverse interior designs—from rustic to modern. The stove can be installed in several configurations, including as a freestanding model or as part of a zero-clearance fireplace.

Installation is straightforward, thanks to the back venting capability, which is particularly beneficial for homes with limited installation space. The unit is also equipped with a thermostat control system for improved user convenience.

Overall, the Jotul GF300 BV combines innovative technology with timeless design, making it a top choice for anyone looking to add warmth and style to their home. Its blend of efficiency, aesthetic appeal, and adaptability ensures it remains a popular choice in the world of gas heating solutions. Whether used in a cozy den or a grand living room, this gas stove will undoubtedly enhance the overall comfort and atmosphere of any space.