Jotul GF300 BV manual Fuel Conversion Procedure, Tools required, Burner Skirt, Open Close

Page 11

Fuel Conversion

The GF 300 BV gas stove is shipped from the factory equipped to burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be converted for use with propane. Use Propane Conversion Kit

155592, supplied with the appliance.

Order and install NG Conversion Kit 155593 to change back to use with natural gas.

WARNING:

THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE PROVINCIAL AU- THORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIRE- MENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.

AVERTISEMENT:

Cet equipement de conversion sera installe par une agence qualkfiee de service conformenment aux instructions du fabricant et toutes exigences et codes applecables de l’autorises avoir la juridiction. Si l’informaiton dans cette Instruc- tion n’est pas suivie exactement, un feu, explo- sion ou production de protoxyde de carbone peut resulter le dommages causer de propriete, perte ou blessure personnelle de vie. L’agence qualifiee’ de service est esponsable de l’installation propre de cet equipement. L’installation n’est pas propre et complete jusqu’a l’operation de l’appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provisionnees avec l’equipement.

Tools required:

1/2” open ended wrench or deep-well socket, Torx T20 or slotted screwdriver, 4 mm allen wrench.

Conversion Kit Contents:

1, regulator tower labeled for propane

3, regulator tower screws

1, burner orifice (#39 for NG, #53 for LPG)

1, pilot orifice (#51 for NG, #30 for LPG)

Label A - to be completed and applied to the back of the stove

Label B - apply to the stove’s Rating Plate

Small valve label - apply to valve body

Conversion instructions are also shipped in the stove with the conversion kit.

Fuel Conversion Procedure

1.Turn off gas supply to stove.

2.Remove the stove Top Plate.

3.Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page 5. Carefully lift the glass panel up and out of the stove.

4.If installed, remove the Embers and Log Set using care not to damage the fragile log parts.

5.Lift out the Burner Skirt shown in fig.11.

6.Reach under the stove and remove the Air Shutter wingnut from its stud. As you face the right side, it is the one closest to you. See fig. 12.

Burner Skirt

Figure 11. Lift and remove the Burner Skirt from within the firebox.

Open Close

Figure 12. Locate and remove the Air Shutter wingnut from under the right side of the stove.

11

Image 11
Contents GF 300 BV Allagash Installation and Operation InstructionsWelcome to Jøtul Jøtul GF 300 BV Allagash Gas Heater Table of ContentsInput Rates Suggested Tools for Installation and ServiceGlass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Vertical Run All sides 1 25 mm Minimum Alcove DimensionsMinimum Clearances from the Vent Pipe to Combustibles Horizontal RunVent Requirements Hood When installing at an altitude above 2000’Minimum Is 7 feet Approved B-Vent ConfigurationsBurner Skirt Fuel Conversion ProcedureFuel Conversion Tools requiredBurner Orifice Burner PlateRetainer Clip Valve Pilot Base From regulator assemblyGas Supply Connection Pilot Head Regulator Tower Orifice11.0 Gas PressureLeak test Install Right Log Log Set InstallationTo adjust the air shutter Flame Appearance / Air Shutter AdjustmentOptional Wall Thermostat or Remote Control Remote ControlMin Installing Decorative PipeSpill Switch System CheckOperation Blocked Flue SwitchBurner and Logset Annual CleaningGlass Care Vent SystemOptional Blower # Connect power cord to the nearest outletControl Blower OperationSpeed Replace the Top Plate Optional Antique Brick KitReplace with #40 Orifice High Altitude AdjustmentDerating Procedure GF 300 BV Allagash Illustrated Parts Breakdown Accessories GF 300 BV Allagash Parts ListPurchased from Name of InstallerModel Name Serial Number Date of PurchasePush in gas control knob slightly and turn clockwise toOFF Control ValveJøtul North America October 2005 137945-CJøtul AS Box Fredrikstad Norway

GF300 BV specifications

The Jotul GF300 BV is a contemporary gas stove that epitomizes elegance and efficiency. Known for its robust construction and exceptional performance, it serves as both a reliable heating source and a stunning centerpiece in any living space. This model is particularly popular among homeowners looking to blend functionality with aesthetic appeal.

One of the standout features of the Jotul GF300 BV is its advanced heating technology. Equipped with a powerful burner system, it delivers efficient heat while maintaining low emissions. The stove has a maximum output of 30,000 BTUs, making it suitable for a variety of room sizes. This capacity not only ensures ample warmth but also contributes to a consistent and pleasant environment during colder months.

The design of the GF300 BV is particularly noteworthy, featuring a large glass front that allows for an unobstructed view of the mesmerizing flames. This design choice enhances the ambiance of any room, transforming a simple heating appliance into a focal point. The stove also includes an adjustable flame height feature, allowing users to customize the intensity of the fire according to their preference.

In terms of efficiency, the Jotul GF300 BV is a leader in its class. It boasts an impressive efficiency rating, which translates to lower energy costs for homeowners. Additionally, the unit is designed to work seamlessly with modern home ventilation systems, ensuring optimal performance without compromising air quality.

Another significant characteristic of the Jotul GF300 BV is its versatility. It is available in a variety of finishes and styles, allowing it to complement diverse interior designs—from rustic to modern. The stove can be installed in several configurations, including as a freestanding model or as part of a zero-clearance fireplace.

Installation is straightforward, thanks to the back venting capability, which is particularly beneficial for homes with limited installation space. The unit is also equipped with a thermostat control system for improved user convenience.

Overall, the Jotul GF300 BV combines innovative technology with timeless design, making it a top choice for anyone looking to add warmth and style to their home. Its blend of efficiency, aesthetic appeal, and adaptability ensures it remains a popular choice in the world of gas heating solutions. Whether used in a cozy den or a grand living room, this gas stove will undoubtedly enhance the overall comfort and atmosphere of any space.