Jotul GF300 BV manual Unpacking your stove, Glass Panel, Hardware Bag Contents

Page 5

General Information

„THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

„The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

„This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certi- fied kit is used.

Cet appareil peut être installé dans un maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.

Cet appareil doit être utilisé uniquement avec les types de gas indiqués sur la plaque signalétique. Ne pas l’utiliser ave d’autres gas sauf si un kitde conver- sion certifié est installé.

„This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passage- ways of the appliance be kept clean.

„THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.

„The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installa- tion. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to determine what regulations apply in your area.

„CODE COMPLIANCE: Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in this manual, defaults to local code. In the absence of local codes, the installa- tion requirements must comply with the current edition of National codes. In the U.S., these require- ments are established in the National Fuel Code, ANSI Z223.1.(NFPA 54) current edition. In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code, current edition.

Consult the local or national installation code(s) to assure that adequate combustion and ventilation air is available.

„Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

„DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

„Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Glass Panel

Do not operate this appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Unpacking your stove

1.Remove the Top Plate of the stove by simply lifting it straight off of the stove body.

2.To open the firebox, disengage the two Glass Frame Latches located on top of the firebox. Pull each handle forward to clear the latch from the notch in the frame.

Glass Frame

Latch

3.Familiarize yourself with the installation require- ments specified in this manual, before beginning the installation.

Hardware Bag Contents

Fuel Conversion Kit - LP ................................ 155592 * Decorative Pipe Brackets ............................. 129469

5

Image 5
Contents GF 300 BV Allagash Installation and Operation InstructionsWelcome to Jøtul Jøtul GF 300 BV Allagash Gas Heater Table of ContentsInput Rates Suggested Tools for Installation and ServiceGlass Panel Hardware Bag ContentsUnpacking your stove Hearth Requirements Safety InformationLocation Minimum Clearances from the Vent Pipe to Combustibles Minimum Alcove DimensionsHorizontal Run Vertical Run All sides 1 25 mmVent Requirements Hood When installing at an altitude above 2000’Minimum Is 7 feet Approved B-Vent ConfigurationsFuel Conversion Fuel Conversion ProcedureTools required Burner SkirtBurner Orifice Burner PlateGas Supply Connection From regulator assemblyPilot Head Regulator Tower Orifice Retainer Clip Valve Pilot Base11.0 Gas PressureLeak test Install Right Log Log Set InstallationOptional Wall Thermostat or Remote Control Flame Appearance / Air Shutter AdjustmentRemote Control To adjust the air shutterSpill Switch Installing Decorative PipeSystem Check MinOperation Blocked Flue SwitchGlass Care Annual CleaningVent System Burner and LogsetOptional Blower # Connect power cord to the nearest outletControl Blower OperationSpeed Replace the Top Plate Optional Antique Brick KitReplace with #40 Orifice High Altitude AdjustmentDerating Procedure GF 300 BV Allagash Illustrated Parts Breakdown Accessories GF 300 BV Allagash Parts ListModel Name Serial Number Name of InstallerDate of Purchase Purchased fromPush in gas control knob slightly and turn clockwise toOFF Control ValveJøtul AS October 2005 137945-CBox Fredrikstad Norway Jøtul North America

GF300 BV specifications

The Jotul GF300 BV is a contemporary gas stove that epitomizes elegance and efficiency. Known for its robust construction and exceptional performance, it serves as both a reliable heating source and a stunning centerpiece in any living space. This model is particularly popular among homeowners looking to blend functionality with aesthetic appeal.

One of the standout features of the Jotul GF300 BV is its advanced heating technology. Equipped with a powerful burner system, it delivers efficient heat while maintaining low emissions. The stove has a maximum output of 30,000 BTUs, making it suitable for a variety of room sizes. This capacity not only ensures ample warmth but also contributes to a consistent and pleasant environment during colder months.

The design of the GF300 BV is particularly noteworthy, featuring a large glass front that allows for an unobstructed view of the mesmerizing flames. This design choice enhances the ambiance of any room, transforming a simple heating appliance into a focal point. The stove also includes an adjustable flame height feature, allowing users to customize the intensity of the fire according to their preference.

In terms of efficiency, the Jotul GF300 BV is a leader in its class. It boasts an impressive efficiency rating, which translates to lower energy costs for homeowners. Additionally, the unit is designed to work seamlessly with modern home ventilation systems, ensuring optimal performance without compromising air quality.

Another significant characteristic of the Jotul GF300 BV is its versatility. It is available in a variety of finishes and styles, allowing it to complement diverse interior designs—from rustic to modern. The stove can be installed in several configurations, including as a freestanding model or as part of a zero-clearance fireplace.

Installation is straightforward, thanks to the back venting capability, which is particularly beneficial for homes with limited installation space. The unit is also equipped with a thermostat control system for improved user convenience.

Overall, the Jotul GF300 BV combines innovative technology with timeless design, making it a top choice for anyone looking to add warmth and style to their home. Its blend of efficiency, aesthetic appeal, and adaptability ensures it remains a popular choice in the world of gas heating solutions. Whether used in a cozy den or a grand living room, this gas stove will undoubtedly enhance the overall comfort and atmosphere of any space.