Jotul GF300 BV manual Installation and Operation Instructions, GF 300 BV Allagash

Page 1

GF 300 BV Allagash

Gas Stove

Installation and Operation Instructions

WARNING:

IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-

SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN- ITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION:

INSTALLATION AND SERVICE MUST BE PER- FORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR LICENSED GAS SUPPLIER.

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS.

A CARBON MONOXIDE (CO) DETECTOR SHALL BE INSTALLED IN THE SAME ROOM AS THE APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRICAL SWITCHES.

DO NOT USE THE PHONE IN YOUR BUILDING. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.

FOLLOW YOUR GAS SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

AVERTISSEMENT:

ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUC- TIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE RISQUE D’INCENDIE OU POUR EVITER TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU MORTALIT’E.

NE PAS ENTREPOSER NI UTILISER D’ESSENCE NI OU LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.

L’INSTALLATION LE SERVICE DOIVENT ETRE EXECUTES PAR UN INSTALLATEUR QUALIFIE, AGENCE DE SERVICE OU LE FOURNISSEUR DE GAZ.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.

NE PAS TENTER D’ALLUMER L’APPAREIL

NE TOUCHEZ A AUCUM NTERRUPTEUR.

NE PAS VOUS SERVIR DES TELEPHONES SE TROUVANT DANS LE BATIMENT OU VOUS VOUS TROUVEZ.

APPELEZ IMMEDIATEMENT VOTRE FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ LES INSTRUC- TIONS DU FOURNISSEUR.

SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR DE GAZ, APPELEZ LE SERVICE DES INCENDIES.

1

Image 1
Contents GF 300 BV Allagash Installation and Operation InstructionsWelcome to Jøtul Jøtul GF 300 BV Allagash Gas Heater Table of ContentsInput Rates Suggested Tools for Installation and ServiceUnpacking your stove Hardware Bag ContentsGlass Panel Location Safety InformationHearth Requirements Minimum Clearances from the Vent Pipe to Combustibles Minimum Alcove DimensionsHorizontal Run Vertical Run All sides 1 25 mmVent Requirements Hood When installing at an altitude above 2000’Minimum Is 7 feet Approved B-Vent ConfigurationsFuel Conversion Fuel Conversion ProcedureTools required Burner SkirtBurner Orifice Burner PlateGas Supply Connection From regulator assemblyPilot Head Regulator Tower Orifice Retainer Clip Valve Pilot BaseLeak test Gas Pressure11.0 Install Right Log Log Set InstallationOptional Wall Thermostat or Remote Control Flame Appearance / Air Shutter AdjustmentRemote Control To adjust the air shutterSpill Switch Installing Decorative PipeSystem Check MinOperation Blocked Flue SwitchGlass Care Annual CleaningVent System Burner and LogsetOptional Blower # Connect power cord to the nearest outletSpeed Blower OperationControl Replace the Top Plate Optional Antique Brick KitDerating Procedure High Altitude AdjustmentReplace with #40 Orifice GF 300 BV Allagash Illustrated Parts Breakdown Accessories GF 300 BV Allagash Parts ListModel Name Serial Number Name of InstallerDate of Purchase Purchased fromPush in gas control knob slightly and turn clockwise toOFF Control ValveJøtul AS October 2005 137945-CBox Fredrikstad Norway Jøtul North America

GF300 BV specifications

The Jotul GF300 BV is a contemporary gas stove that epitomizes elegance and efficiency. Known for its robust construction and exceptional performance, it serves as both a reliable heating source and a stunning centerpiece in any living space. This model is particularly popular among homeowners looking to blend functionality with aesthetic appeal.

One of the standout features of the Jotul GF300 BV is its advanced heating technology. Equipped with a powerful burner system, it delivers efficient heat while maintaining low emissions. The stove has a maximum output of 30,000 BTUs, making it suitable for a variety of room sizes. This capacity not only ensures ample warmth but also contributes to a consistent and pleasant environment during colder months.

The design of the GF300 BV is particularly noteworthy, featuring a large glass front that allows for an unobstructed view of the mesmerizing flames. This design choice enhances the ambiance of any room, transforming a simple heating appliance into a focal point. The stove also includes an adjustable flame height feature, allowing users to customize the intensity of the fire according to their preference.

In terms of efficiency, the Jotul GF300 BV is a leader in its class. It boasts an impressive efficiency rating, which translates to lower energy costs for homeowners. Additionally, the unit is designed to work seamlessly with modern home ventilation systems, ensuring optimal performance without compromising air quality.

Another significant characteristic of the Jotul GF300 BV is its versatility. It is available in a variety of finishes and styles, allowing it to complement diverse interior designs—from rustic to modern. The stove can be installed in several configurations, including as a freestanding model or as part of a zero-clearance fireplace.

Installation is straightforward, thanks to the back venting capability, which is particularly beneficial for homes with limited installation space. The unit is also equipped with a thermostat control system for improved user convenience.

Overall, the Jotul GF300 BV combines innovative technology with timeless design, making it a top choice for anyone looking to add warmth and style to their home. Its blend of efficiency, aesthetic appeal, and adaptability ensures it remains a popular choice in the world of gas heating solutions. Whether used in a cozy den or a grand living room, this gas stove will undoubtedly enhance the overall comfort and atmosphere of any space.