Performance Data Sheet

SmartWater Filtration System

GSWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*

(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Influent Challenge

Effluent

% Reduction

Min. Required

 

MCL

Average

Concentration

Average

Maximum

Average

Minimum

Reduction

Chlorine

1.845 mg/L

2.0 mg/L+10%

< 0.05 mg/L

0.05 mg/L

> 97.29%

96.43%

> 50%

T & O

Particulate**

143,333 #/mL

at least 10,000 particles/mL

29.83 #/mL

140 #/mL

99.98%

99.91%

> 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Influent Challenge

Effluent

% Reduction

Min. Required

 

MCL

Average

Concentration

Average

Maximum

Average

Minimum

Reduction

Turbidity

1 NTU***

10.3 NTU***

1+1 NTU***

0.106 NTU

0.14 NTU

98.97%

98.61%

0.5 NTU

Cysts

99.95% Reduction

200,000 #/L

Minimum 50,000 L

0

0

> 99.99%

> 99.99%

> 99.95%

Lead at pH 6.5

0.015 mg/L

0.15 mg/L

0.15 mg/L+10%

< 0.001 mg/L

< 0.001 mg/L

> 99.33%

> 99.33%

0.010 mg/L

Lead at pH 8.5

0.015 mg/L

0.14 mg/L

0.15 mg/L+10%

0.001 mg/L

0.003 mg/L

> 99.29%

97.86%

0.010 mg/L

Lindane

0.0002 mg/L

0.0216 mg/L

0.002 mg/L+10%

< 0.00002 mg/L

< 0.00002 mg/L

99.07%

98.75%

0.0002 mg/L

Atrazine

0.003 mg/L

0.008 mg/L

0.009 mg/L+10%

< 0.002 mg/L

< 0.002 mg/L

> 76.12%

> 66.67%

0.003 mg/L

*Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) ** Measurement in Particles/ml. Particles used were 0.5-1 microns

*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 750 gallons (2,838 l); up to six months

Pressure requirement: 40–120 psi (2.8–8.2 bar)

Temperature: 33–100ºF (0.6–38ºC)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.

Replace cartridge when flow becomes too slow.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped. This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the state and local laws and regulations.

Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

System tested and certified by NSF International against Standard 42 for the reduction of chlorine, taste and odor, particulate Class I and Standard 53 for the reduction of cyst, lead, Lindane, Atrazine and turbidity.

NSF®

Manufactured for: General Electric Company, Louisville, KY 40225

41

Page 41
Image 41
GE 197D4618P003 Performance Data Sheet, Operating Specifications, General Installation/Operation/Maintenance Requirements

197D4618P003 specifications

The GE 197D4618P003 is an advanced electrical component designed for various applications, commonly found within industrial power systems. This component demonstrates GE's commitment to providing reliability, efficiency, and technological innovation. With a robust design, the 197D4618P003 serves as a vital part in ensuring optimal performance in electrical circuits and systems.

One of the main features of the GE 197D4618P003 is its versatile compatibility with various GE equipment and systems. This ensures that it can effectively integrate into existing setups, minimizing the need for extensive modifications. Its design considers the rigorous demands of industrial environments, ensuring that it has a long operational life even when subjected to acute stress.

The 197D4618P003 incorporates cutting-edge technology to enhance reliability and operational efficiency. It features advanced materials that provide exceptional resistance to wear and tear, making it suitable for high-load applications. Enhanced thermal management is another hallmark of this component, allowing it to operate efficiently under diverse temperature conditions. This feature is crucial for maintaining system stability and prolonging equipment lifespan.

Furthermore, this component is equipped with sophisticated protection mechanisms, safeguarding it from electrical surges and other potential hazards. By maintaining a smooth operation and preventing unexpected failures, the 197D4618P003 contributes to overall system reliability. This feature is particularly beneficial in preventing downtime, ultimately leading to cost savings for businesses.

The GE 197D4618P003 also emphasizes energy efficiency. The design aligns with modern energy standards, contributing to reduced power consumption and lower operational costs. This is increasingly important in a world where energy efficiency is paramount for both environmental considerations and regulatory compliance.

In summary, the GE 197D4618P003 is an essential electrical component that embodies advanced technology, robust design, and user-friendly features. Its compatibility with existing systems, combined with superior durability and efficiency, makes it an indispensable element for industries relying on dependable power solutions. Whether deployed in manufacturing, energy production, or any industrial application, the 197D4618P003 will provide the reliability and performance needed to meet today’s demanding operational requirements.