Maintenance

Pellet fines will accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this must be performed.

To clean out fines:

1.Remove right rear cover panel.

2.Remove wing nut and feeder cover on the right side of the feeder. See Fig. 43.

3.Use a vacuum cleaner to remove all fines.

4.Reinstall feed cover, wing nut, and right rear cover panel.

Two 5/16" socket hex screws on each side.

Fig. 42

Feeder cover gasket

Feeder cover

Wing

Nut

Pellet Fines will build

Fig. 43

up in this area

 

 

 

Viewing Glass

 

 

The glass in your Harman stove is a special ceramic glass.

Do not abuse the glass by striking or slamming the door.

Never burn the appliance if the door glass is cracked or broken.

Replace only with Harman supplied 5mm ceramic glass.

Soot and/or fly-ash may accumulate on the viewing glass, and will ocassionally need to be cleaned. Clean the glass with a soft cloth and mild glass cleaner. Do not clean the glass when hot, and avoid the use of abrasive cleaners.

Glass replacement

Carefully remove all remaining glass and gasket materials prior to replacing the glass.

Lay the door face down on a flat surface. Remove the glass retainers and screws. Apply the gasket material to the face of the new glass. Lay the glass into the door, making sure that the glass is contained within

the channels and raised areas of the door itself. Lay the glass retainers into position and install the screws. Tighten each screw evenly to avoid making any stress points.

Gasket

Glass

Screws &

Retainers

XXV Pellet Stove 27

Image 27
Contents R16 Installation & Operating ManualPage Fuel and Fuel Storage Fuel SpecificationsSerial # Introduction Appliance CertificationModel Important Notes Assembly and InstallationFloor Protection InstallationVenting Addition, the following must be observedApplies Do not connect to any air distribution duct or system VentingVent Pipe Direct Vent Wall Passthrough Avoiding Smoke and Odors#2 Preferred method #1 Preferred method#3 Installing into an existing chimney #6 Installing into an existing chimney US and Canada #8 Installing through the ceiling Vent Configurations Minimum flue vent configurationESP Control Blinks In Igniter Auto. Mode Only Indicates thatLow Draft Voltage Adjustment Low Draft Voltage AdjustmentAutomatic IGNITION/OPERATION Room Temperature ModeStove Temperature Mode Feed Adjuster KnobShut Down Procedure Automatic Start UP Turn Feed Adjuster to #4.4Room Temperature Mode Stove Temperature ModeManual IGNITION/Operation Igniter Switch to Manual up position Manual Start UPFill the hopper with pellets and remove ashes as required.1 Room sensor Installation Room Sensor Installation Maintenance Cleaning Removing Ashes ESP Maintenance Burn Pot Burn Pot Cleaning and MaintenanceNot coiled inside the burn pot Viewing Glass Harman OptionsXXV Top Flue Option Direct Vent Wall PassthroughFuel Trouble-ShootingCleaning Burn Pot Helpful HintsWiring Diagram SpecificationsXXV Pellet Stove Hearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsOperation in Stove Temp mode Operation in Room Temp modeChanges to Maintenance Schedule Part number list on following Service PartsActive Retired unitsStocked At depotNo longer available Stocked at depotXXV Pellet Stove Stocked #44 Feeder assembly Post Serial numberHardware Packages Service & Maintenance Log Service & Maintenance Log Page Proudly Printed On 100% Recycled Paper Signature of Boxer