Fujitsu Room Air Conditioner Multi Split Type (3 rooms) During Cooling/Dry mode, During Fan mode

Page 11

To Select Automatic Operation

Press the MASTER CONTROL button to select AUTO.

The operating mode “AUTO” will appear alone in the display. The transmit indi- cator will flash to indicate the command has been sent, and about three sec- onds later the entire display panel will reappear.

To Set the Thermostat

Press the TEMPERATURE set button.

LOW HIGH

LOW HIGH

LOW HIGH

LOW HIGH

LOW HIGH

When set to

When set to

When set to

When set to

When set to

4 °F lower

2 °F lower

“normal”

2 °F higher

4 °F higher

About three seconds later, the entire display will reappear.

NOTE: The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.

To Stop Operation

Press the START/STOP button.

The OPERATION indicator lamp (red) (Fig. 3 5) will go out.

About Mode Operation

AUTO:

Depending on the room temperature at the time operation begins, the operating mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature setting will cause the “standard” temperature to be set as shown.

Actual Room

 

Operating Mode

 

Thermostat Setting

Temperature

 

 

 

(standard setting)

88 °F or above

Cooling

82 °F

82 to 88 °F

Cooling

80 °F

78 to 82 °F

Dry

76 °F

74 to 78 °F

Dry

72 °F

Below 74 °F

Dry

68 °F

The operating mode and standard thermostat settings are selected automatically when operation begins.

When automatic operation is initiated, the fan will run at very low speed for about one minute while the unit detects and selects the proper operating mode.

Once the operating mode has been set, the mode will not change even if the room temperature changes.

If the START/STOP button is pressed to recommence operation within two hours after stopping automatic operation, the unit will begin operating from the same mode as before.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate warm air from ceiling area throughout room when using space heaters.

Example: When set to “normal”

During Cooling/Dry mode:

Set the thermostat to a temperature setting that is lower than the current room tempera- ture. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will operate).

During Fan mode:

Fan operation begins when room tem- perature in the vicinity of the air condi- tioner rises above the set thermostat temperature; when the temperature drops, fan operation stops.

If the air emitted feels too cool, raise the thermostat setting.

En-10

Image 11
Contents English Multi Split Type 3 RoomsASU18T AOU36TSafety Precautions ContentsAIR Cleaning Filter Optional Features and FunctionsPage Name of Parts En-5 Name of PartsOutdoor Unit Intake Side F Outlet Side Time Adjust Button S Test RUN ButtonPreparation Press the Time Adjust button againTo Use the Remote Control Unit Remote Control Unit HolderPreparation To Set the Fan Speed Press the FAN Control button O To Select Mode Operation Press the START/STOP button POperation To Set the Thermostat Press the SET TEMP. buttons LTo Stop Operation Press the START/STOP button To Set the Thermostat Press the Temperature set buttonDuring Cooling/Dry mode During Fan modeTo Set the Fan Speed Press the FAN Control button To Select Mode Operation Press the START/STOP buttonOperation To Set the Thermostat Press the SET TEMP. buttonsAbout Mode Operation Set the desired times for OFF timer and on timer Timer OperationTo Use the Program timer Press the START/STOP button About the Sleep timer Sleep Timer OperationAbout the Program timer About the on timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationTo select Swing Operation Press the Swing Louver button R Swing OperationManual Auto Operation About Swing Operation Swing OperationTo Stop Vertical airflow Swing Operation To Stop Horizontal airflow Swing OperationAbout the Energy Save Energy Save OperationManual Auto Operation Cleaning and Care Lock the Intake Grille Cleaning the Intake Grille Open the Intake GrilleClean with water Unlock the Intake GrilleSymptom Problem TroubleshootingEn-23 Operating Tips Temperature and Humidity Range

ASU18T, Room Air Conditioner Multi Split Type (3 rooms), AOU36T specifications

The Fujitsu AOU36T is a highly efficient multi-split room air conditioning system designed to provide optimal comfort across three rooms. Its versatility and advanced technology make it an ideal solution for residential and commercial spaces. With a combination of the outdoor unit (AOU36T) and indoor units (ASU18T), this system showcases Fujitsu's commitment to quality and performance.

One of the main features of the AOU36T system is its energy efficiency, classified with a high SEER (Seasonal Energy Efficiency Ratio) rating. This means it consumes less energy while delivering powerful cooling and heating output, making it an environmentally friendly choice that also reduces utility bills. The unit is equipped with inverter technology, which allows the compressor to adjust its speed based on the cooling needs of the spaces, leading to quieter operation and increased energy savings.

The ASU18T indoor units feature a sleek and modern design that seamlessly integrates into various interior aesthetics. They are equipped with advanced air filtration systems to ensure clean and healthy air is circulated within the rooms. The filters capture dust, allergens, and other pollutants, enhancing indoor air quality, an essential aspect for families and individuals with respiratory issues.

An important characteristic of the Fujitsu AOU36T system is its ultra-quiet operation. The outdoor unit is designed to minimize noise levels, while the indoor units also operate quietly, ensuring that the comfort is not disrupted by loud mechanical sounds. This feature makes it perfect for bedrooms, offices, and other noise-sensitive environments.

The multi-split system also includes smart technology features, allowing users to control the temperature and settings remotely using a smartphone app. This provides convenience and flexibility, enabling adjustments based on individual preferences and schedules.

Moreover, the AOU36T supports heating functionality, making it a reliable choice for year-round climate control. It can effectively manage heating needs even in colder temperatures, providing warmth and comfort during winter months.

In conclusion, the Fujitsu AOU36T multi-split air conditioning system with ASU18T indoor units offers a comprehensive solution for effective climate control in multiple rooms. Its combination of energy efficiency, advanced technology, quiet operation, and smart features make it an excellent choice for those seeking comfort without compromising on performance or environmental responsibility.