AUTO:

COOLING MODEL

When the room temperature is 4 °F higher than the set temperature, the mode will switch between Cooling and Drying.

During the Drying mode operation, the FAN setting should be switched to LOW for a gently cooling effect during which the fan may temporarily stop rotating.

If the mode automatically selected by the unit is not satisfactory, see page 6 for in- structions on changing the mode setting (COOL, DRY, FAN).

Cooling Operation

Dry Operation

Thermostat control

4°F

Setting temperature

AUTO (* AUTO CHANGEOVER):

HEAT & COOL MODEL (Reverse cycle)

When AUTO CHANGEOVER is selected, the air conditioner selects the appropri- ate operation mode (Cooling or Heating) according to your room’s present tem- perature.

When AUTO CHANGEOVER is first selected, the fan will operate at very low speed for about one minute while the unit determines the current conditions of the room and accordingly selects the proper operation mode.

When the air conditioner has adjusted your room’s temperature to near the ther- mostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cool-

ing) to adjust the temperature to the value set in the thermostat. (The monitor operation range is ±4 °F relative to the thermostat setting.)

If the mode automatically selected by the unit is not satisfactory, see page 6 for instructions on changing the mode setting (HEAT, COOL, DRY, FAN).

*Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan set- ting. This period of time is provided to allow the indoor unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic De- frosting operation, the OPERATION indicator light (red) will flash, and the heat operation will be interrupted.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate the air throughout your room.

* During Heating mode:

Set the thermostat to a temperature set- ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set- ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper- ate).

During Fan mode:

The heat and cool functions of this unit cannot operate in the Fan mode.

En-12

Image 13
Contents ASU18T Multi Split Type 3 RoomsAOU36T EnglishSafety Precautions ContentsAIR Cleaning Filter Optional Features and FunctionsPage Name of Parts En-5 Name of PartsOutdoor Unit Intake Side F Outlet Side Time Adjust Button S Test RUN ButtonTo Use the Remote Control Unit Press the Time Adjust button againRemote Control Unit Holder PreparationPreparation Operation To Select Mode Operation Press the START/STOP button PTo Set the Thermostat Press the SET TEMP. buttons L To Set the Fan Speed Press the FAN Control button ODuring Cooling/Dry mode To Set the Thermostat Press the Temperature set buttonDuring Fan mode To Stop Operation Press the START/STOP buttonOperation To Select Mode Operation Press the START/STOP buttonTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonAbout Mode Operation To Use the Program timer Press the START/STOP button Timer OperationSet the desired times for OFF timer and on timer About the Program timer Sleep Timer OperationAbout the on timer About the Sleep timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationManual Auto Operation Swing OperationTo select Swing Operation Press the Swing Louver button R To Stop Vertical airflow Swing Operation Swing OperationTo Stop Horizontal airflow Swing Operation About Swing OperationManual Auto Operation Energy Save OperationAbout the Energy Save Cleaning and Care Clean with water Cleaning the Intake Grille Open the Intake GrilleUnlock the Intake Grille Lock the Intake GrilleSymptom Problem TroubleshootingEn-23 Operating Tips Temperature and Humidity Range

ASU18T, Room Air Conditioner Multi Split Type (3 rooms), AOU36T specifications

The Fujitsu AOU36T is a highly efficient multi-split room air conditioning system designed to provide optimal comfort across three rooms. Its versatility and advanced technology make it an ideal solution for residential and commercial spaces. With a combination of the outdoor unit (AOU36T) and indoor units (ASU18T), this system showcases Fujitsu's commitment to quality and performance.

One of the main features of the AOU36T system is its energy efficiency, classified with a high SEER (Seasonal Energy Efficiency Ratio) rating. This means it consumes less energy while delivering powerful cooling and heating output, making it an environmentally friendly choice that also reduces utility bills. The unit is equipped with inverter technology, which allows the compressor to adjust its speed based on the cooling needs of the spaces, leading to quieter operation and increased energy savings.

The ASU18T indoor units feature a sleek and modern design that seamlessly integrates into various interior aesthetics. They are equipped with advanced air filtration systems to ensure clean and healthy air is circulated within the rooms. The filters capture dust, allergens, and other pollutants, enhancing indoor air quality, an essential aspect for families and individuals with respiratory issues.

An important characteristic of the Fujitsu AOU36T system is its ultra-quiet operation. The outdoor unit is designed to minimize noise levels, while the indoor units also operate quietly, ensuring that the comfort is not disrupted by loud mechanical sounds. This feature makes it perfect for bedrooms, offices, and other noise-sensitive environments.

The multi-split system also includes smart technology features, allowing users to control the temperature and settings remotely using a smartphone app. This provides convenience and flexibility, enabling adjustments based on individual preferences and schedules.

Moreover, the AOU36T supports heating functionality, making it a reliable choice for year-round climate control. It can effectively manage heating needs even in colder temperatures, providing warmth and comfort during winter months.

In conclusion, the Fujitsu AOU36T multi-split air conditioning system with ASU18T indoor units offers a comprehensive solution for effective climate control in multiple rooms. Its combination of energy efficiency, advanced technology, quiet operation, and smart features make it an excellent choice for those seeking comfort without compromising on performance or environmental responsibility.