Fujitsu AOU36T, ASU18T To Stop Vertical airflow Swing Operation, About Swing Operation

Page 19

SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button .

The SWING indicator light (VERTICAL SWING) (orange) will turn on.

In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Vertical airflow SWING Operation

Example: When set to vertical swing

 

Press the AIR FLOW DIRECTION VERTICAL SWING button once again.

The SWING indicator light (VERTICAL SWING) will turn off.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 3

2

1 to 4

 

 

3

2 to 5

4

3 to 6

5

4 to 7

6

5 to 7

 

 

7

1 to 7 (All range)

Air direction range (See page 10, Fig. 9)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION VERTICAL SET button to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flaps, in the Heating range (5 to 7) for long periods of time, since water vapor may con- dense near the outlet louvers and drops of water may drip from the air conditioner.

To select Horizontal airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button.

The SWING indicator light (HORIZONTAL SWING) (orange) will turn on.

In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct the airflow both right and left.

SET SWING SET SWING

TIME TEST

ENERGYADJUST RUN ACL

SAVE

To Stop Horizontal airflow SWING Operation

Example: When set to horizontal swing

 

Press the AIR FLOW DIRECTION HORIZONTAL SWING button

 

once again.

 

The SWING indicator light (HORIZONTAL SWING) will turn off.

 

Airflow direction will return to the setting before swing was begun.

 

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 5 (All range)

2

1 to 3

3

2 to 4

4

3 to 5

5

1 to 5 (All range)

 

 

Air direction range (See page 10, Fig. 10)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but- ton to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

En-18

Image 19
Contents English Multi Split Type 3 RoomsASU18T AOU36TSafety Precautions ContentsAIR Cleaning Filter Optional Features and FunctionsPage Name of Parts En-5 Name of PartsOutdoor Unit Intake Side F Outlet Side Time Adjust Button S Test RUN ButtonPreparation Press the Time Adjust button againTo Use the Remote Control Unit Remote Control Unit HolderPreparation To Set the Fan Speed Press the FAN Control button O To Select Mode Operation Press the START/STOP button POperation To Set the Thermostat Press the SET TEMP. buttons LTo Stop Operation Press the START/STOP button To Set the Thermostat Press the Temperature set buttonDuring Cooling/Dry mode During Fan modeTo Set the Fan Speed Press the FAN Control button To Select Mode Operation Press the START/STOP buttonOperation To Set the Thermostat Press the SET TEMP. buttonsAbout Mode Operation To Use the Program timer Press the START/STOP button Timer OperationSet the desired times for OFF timer and on timer About the Sleep timer Sleep Timer OperationAbout the Program timer About the on timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationManual Auto Operation Swing OperationTo select Swing Operation Press the Swing Louver button R About Swing Operation Swing OperationTo Stop Vertical airflow Swing Operation To Stop Horizontal airflow Swing OperationManual Auto Operation Energy Save OperationAbout the Energy Save Cleaning and Care Lock the Intake Grille Cleaning the Intake Grille Open the Intake GrilleClean with water Unlock the Intake GrilleSymptom Problem TroubleshootingEn-23 Operating Tips Temperature and Humidity Range

ASU18T, Room Air Conditioner Multi Split Type (3 rooms), AOU36T specifications

The Fujitsu AOU36T is a highly efficient multi-split room air conditioning system designed to provide optimal comfort across three rooms. Its versatility and advanced technology make it an ideal solution for residential and commercial spaces. With a combination of the outdoor unit (AOU36T) and indoor units (ASU18T), this system showcases Fujitsu's commitment to quality and performance.

One of the main features of the AOU36T system is its energy efficiency, classified with a high SEER (Seasonal Energy Efficiency Ratio) rating. This means it consumes less energy while delivering powerful cooling and heating output, making it an environmentally friendly choice that also reduces utility bills. The unit is equipped with inverter technology, which allows the compressor to adjust its speed based on the cooling needs of the spaces, leading to quieter operation and increased energy savings.

The ASU18T indoor units feature a sleek and modern design that seamlessly integrates into various interior aesthetics. They are equipped with advanced air filtration systems to ensure clean and healthy air is circulated within the rooms. The filters capture dust, allergens, and other pollutants, enhancing indoor air quality, an essential aspect for families and individuals with respiratory issues.

An important characteristic of the Fujitsu AOU36T system is its ultra-quiet operation. The outdoor unit is designed to minimize noise levels, while the indoor units also operate quietly, ensuring that the comfort is not disrupted by loud mechanical sounds. This feature makes it perfect for bedrooms, offices, and other noise-sensitive environments.

The multi-split system also includes smart technology features, allowing users to control the temperature and settings remotely using a smartphone app. This provides convenience and flexibility, enabling adjustments based on individual preferences and schedules.

Moreover, the AOU36T supports heating functionality, making it a reliable choice for year-round climate control. It can effectively manage heating needs even in colder temperatures, providing warmth and comfort during winter months.

In conclusion, the Fujitsu AOU36T multi-split air conditioning system with ASU18T indoor units offers a comprehensive solution for effective climate control in multiple rooms. Its combination of energy efficiency, advanced technology, quiet operation, and smart features make it an excellent choice for those seeking comfort without compromising on performance or environmental responsibility.