ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s AIR FLOW DIRECTION button. Hori- zontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.

Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.

Vertical Air Direction Adjustment

Press the AIR FLOW DIRECTION button (Fig. 6 Q).

Each time the button is pressed, the air direction range will change as follows:

Cooling/Dry

mode

1 2 3 (6) NOTE

Fan mode

1 2 3 4 5 6 7

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.

During Cooling/Dry modes : Horizontal flow 1

During Fan mode

: Downward flow 6

If you wish to select a different airflow direction, you may use the remote control unit’s AIR FLOW DIRECTION button to choose a different setting.

During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this pe- riod.

NOTE

You can select the air direction 1, 2, 3, or 6 (downward) by pressing the AIR FLOW DIRECTION button.

Use the air direction 6 when you want to cool yourself for a while after taking a bath or shower, or after coming back home in summer months.

But, for prevention of condensation on the louver, the air direction 6 is auto- matically released after 30 minutes and turned to the air direction 3.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

Right-Left Louvers

CAUTION!

Never place fingers or foreign objects inside the outlet ports, since the internal fan oper- ates at high speed and could cause personal injury.

Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the vertical airflow louvers. Attempt- ing to move them manually could re- sult in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

When used in a room with infants, chil- dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Always operate the Air Flow Direction Louvers and the Power Diffuser with the air flow direction buttons on the remote control. Forcible movement by hand can cause incorrect operation. In such a case, stop the operation to let the unit return to normal condition.

knob

En-16

Image 17
Contents ASU18T Multi Split Type 3 RoomsAOU36T EnglishSafety Precautions ContentsAIR Cleaning Filter Optional Features and FunctionsPage Name of Parts En-5 Name of PartsOutdoor Unit Intake Side F Outlet Side Time Adjust Button S Test RUN ButtonTo Use the Remote Control Unit Press the Time Adjust button againRemote Control Unit Holder PreparationPreparation Operation To Select Mode Operation Press the START/STOP button PTo Set the Thermostat Press the SET TEMP. buttons L To Set the Fan Speed Press the FAN Control button ODuring Cooling/Dry mode To Set the Thermostat Press the Temperature set buttonDuring Fan mode To Stop Operation Press the START/STOP buttonOperation To Select Mode Operation Press the START/STOP buttonTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonAbout Mode Operation Set the desired times for OFF timer and on timer Timer OperationTo Use the Program timer Press the START/STOP button About the Program timer Sleep Timer OperationAbout the on timer About the Sleep timerTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationTo select Swing Operation Press the Swing Louver button R Swing OperationManual Auto Operation To Stop Vertical airflow Swing Operation Swing OperationTo Stop Horizontal airflow Swing Operation About Swing OperationAbout the Energy Save Energy Save OperationManual Auto Operation Cleaning and Care Clean with water Cleaning the Intake Grille Open the Intake GrilleUnlock the Intake Grille Lock the Intake GrilleSymptom Problem TroubleshootingEn-23 Operating Tips Temperature and Humidity Range

ASU18T, Room Air Conditioner Multi Split Type (3 rooms), AOU36T specifications

The Fujitsu AOU36T is a highly efficient multi-split room air conditioning system designed to provide optimal comfort across three rooms. Its versatility and advanced technology make it an ideal solution for residential and commercial spaces. With a combination of the outdoor unit (AOU36T) and indoor units (ASU18T), this system showcases Fujitsu's commitment to quality and performance.

One of the main features of the AOU36T system is its energy efficiency, classified with a high SEER (Seasonal Energy Efficiency Ratio) rating. This means it consumes less energy while delivering powerful cooling and heating output, making it an environmentally friendly choice that also reduces utility bills. The unit is equipped with inverter technology, which allows the compressor to adjust its speed based on the cooling needs of the spaces, leading to quieter operation and increased energy savings.

The ASU18T indoor units feature a sleek and modern design that seamlessly integrates into various interior aesthetics. They are equipped with advanced air filtration systems to ensure clean and healthy air is circulated within the rooms. The filters capture dust, allergens, and other pollutants, enhancing indoor air quality, an essential aspect for families and individuals with respiratory issues.

An important characteristic of the Fujitsu AOU36T system is its ultra-quiet operation. The outdoor unit is designed to minimize noise levels, while the indoor units also operate quietly, ensuring that the comfort is not disrupted by loud mechanical sounds. This feature makes it perfect for bedrooms, offices, and other noise-sensitive environments.

The multi-split system also includes smart technology features, allowing users to control the temperature and settings remotely using a smartphone app. This provides convenience and flexibility, enabling adjustments based on individual preferences and schedules.

Moreover, the AOU36T supports heating functionality, making it a reliable choice for year-round climate control. It can effectively manage heating needs even in colder temperatures, providing warmth and comfort during winter months.

In conclusion, the Fujitsu AOU36T multi-split air conditioning system with ASU18T indoor units offers a comprehensive solution for effective climate control in multiple rooms. Its combination of energy efficiency, advanced technology, quiet operation, and smart features make it an excellent choice for those seeking comfort without compromising on performance or environmental responsibility.