WIRING

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

16", 18", 24" and 30" Gas Logs (Millivolt) thermopile is self powered gas valve and does not require 110 volts. See Figure 21 to provide optional wall switch, thermostat, or remote control. Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches.

Use the two leads (black wires) from ON/OFF switch to attach optional components.

Check System Operation

Millivolt system and all individual components may be checked with a millivolt meter 0-1000 MV range.

Remote Receiver -VFSR-(16, 18, 24, 30)

Use the following steps to place the remote receiver adjacent to the gas valve.

Attention:

1.The remote receiver can not be placed behind the gas valve and burner assembly.

2.When facing the appliance, the remote receiver must be placed in the right side of firebox, toward the front.

Note: Do not let remote control receiver come in contact with burner assembly.

On circulating vent-free firebox, install remote control receiver behind bottom louver.

Refer to remote control installation and operating instructions for more details on remote control.

750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical current) to buildup to a sufficient level allowing the gas control to operate properly.

Millivolt Control

The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “A” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.

VFSR

Note: (Wiring harness located in envelope)

Connect the 2 - 1/4" terminals onto the TH and TH/TP terminals on valve. Place decorative log or switch bracket (switch bracket is used with Flame Art log sets) to right of the gas valve and burner assembly. When connecting to remote receiver, cut off 1/ 4" terminals from wires attached to ON/OFF switch. Strip wires back about 1/4". Connect stripped ends into remote receiver.

VFSR Wiring Diagram (Figure 21)

Figure 21

VFSV Wiring Diagram (Figure 22)

Figure 22

VFSV

Note: (Wiring harness located in envelope)

Connect black/red 3/16" terminal wire from receiver to 3/16" terminal on valve. Connect black 1/4" terminal wire from receiver to 1/4" terminal on valve. Install remote receiver cover over receiver when receiver is installed into fireplace area. Locate receiver and cover to the right and forward of valve. (Do not put receiver behind logs)

Page 18

14008-0-0403

Image 18
Contents Installation Instructions Table of Contents Important Safety Information Do not Tamper with Pilot Light Safety SystemCarbon Monoxide Poisoning MAY Lead to Death Safety Information for Users of LP-GAS LP-GAS Warning OdorAccessories IntroductionGeneral Information Before you get startedMake sure you have received all parts Clearances Provisions for Adequate Combustion & Ventilation AIRClearances Combustible Material Fireplace PreparationInstalling AS a Vented Appliance Before Fully Installing the ApplianceInstalling Damper Clamp Figure Installing a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Proper Installation Sequence LOG Grate PlacementPlacement of Glowing Embers and Lava Rock Vfsr and VFSV-16, 18, 24, 30C FigureOperation INSTRUCTIONS/FLAME Appearance Variable Figure Millivolt FigureVFSR-16, 18, 24, 30 Lighting Instructions What to do if YOU Smell GASVFSV-16, 18, 24, 30 Lighting Instructions Vfsv Pilot Pilot Flame CharacteristicsVfsr Pilot Correct Pilot Flame Pattern Incorrect Pilot Flame PatternCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningWiring VfsrVfsv New Installation Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsParts List Common PartsParts View HOW to Order Repair Parts Service Notes Service Notes Mail info@empirecomfort.com