Empire Comfort Systems VFSR-18-3 Installing AS a Vented Appliance, Installing Damper Clamp Figure

Page 10

INSTALLING AS A VENTED APPLIANCE

Notice (Damper Clamp Installation)

When installing your log set as a vented installation the damper clamp must be used.

Figure 9

When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burn- ing the logs for the first time.

Installing Damper Clamp (Figure 9)

Remove all ashes or other debris from the fireplace. If the fireplace is equipped with an ash dump be sure to seal the door with furnace cement or high temperature silicone. Be sure to check the damper for proper operation and verify that the flue passageway is open.

Place the clamp over the lip of the damper and tighten the hold down bolt until the clamp is securely attached to the damper. This will prevent the damper from accidentally closing.

Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code. When the gas logs are operated with the damper open, non-combustible material and minimum mantel re- quirements do not apply.

State of Massachusetts requirement for installation of vented decorative appliance in a vented fireplace is the following:

A vented decorative gas appliance must be installed in a vented fireplace only in the state of Massachusetts. The vent damper must be removed or welded permanently open.

BEFORE FULLY INSTALLING THE APPLIANCE

Turn off the gas supply to the fireplace or firebox.

Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.

Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning. Grate movement could cause a gas leak.

Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials.

Assembly Procedure: (Figure 10)

1.Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the fireplace or firebox.

2.An anchor hole is provided in the two bottom side members of the grate frame. After centering the grate correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/ 32" diameter holes approximately 1-1/2" deep for masonry screws or 1/8" hole for sheet metal screws.

3.Anchor the grate to the fireplace/firebox floor using the screws provided. Refer to Figure10.

Proper installation of the grate is essential to prevent any movement of the gas logs and controls during operation.

Figure 10

Page 10

14008-0-0403

Image 10
Contents Installation Instructions Table of Contents Do not Tamper with Pilot Light Safety System Important Safety InformationCarbon Monoxide Poisoning MAY Lead to Death Safety Information for Users of LP-GAS LP-GAS Warning OdorAccessories IntroductionBefore you get started General InformationMake sure you have received all parts Clearances Provisions for Adequate Combustion & Ventilation AIRClearances Combustible Material Fireplace PreparationBefore Fully Installing the Appliance Installing AS a Vented ApplianceInstalling Damper Clamp Figure Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Proper Installation Sequence LOG Grate PlacementPlacement of Glowing Embers and Lava Rock Vfsr and VFSV-16, 18, 24, 30C FigureOperation INSTRUCTIONS/FLAME Appearance Variable Figure Millivolt FigureVFSR-16, 18, 24, 30 Lighting Instructions What to do if YOU Smell GASVFSV-16, 18, 24, 30 Lighting Instructions Vfsv Pilot Pilot Flame CharacteristicsVfsr Pilot Correct Pilot Flame Pattern Incorrect Pilot Flame PatternCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningVfsr WiringVfsv New Installation Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsParts List Common PartsParts View HOW to Order Repair Parts Service Notes Service Notes Mail info@empirecomfort.com