Empire Comfort Systems VFSR-18-3, VFSR-16-3 General Information, Before you get started

Page 6

GENERAL INFORMATION

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.

Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appliance. Water vapor produced by an unvented heater can create moisture problems in a home when operated for extended periods of time.

During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last 2-3 hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.

Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and replace any part of the control system and any gas control which has been under water.

Before you get started

Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not attempt to install any part of the appliance unless you have all parts in good condition.

Make sure you have received all parts:

Check your packing list to verify that all listed parts have been received. You should have the following:

Gas log grate/burner assembly.

Two (2) masonry anchoring screws and two (2) 10 x 1/2" black sheet metal anchoring screws.

Plastic bag containing glowing embers (rock wool) for burner coverage.

Plastic bag containing lava rock.

Switch log assembly - VFSR models

Remote kit - VFSV models

Millivolt controlled heater designed to be operated with optional devices for ON/OFF functions.

Wall switch or thermostat with wire.

Hand held remote control with ON/OFF switch or thermostat.

Handle the gas log burner assembly by the grate and legs only. Do not pick the unit up by the burner.

Gloves are recommended when handling logs to prevent skin irritation. Logs are fragile - Handle with care.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equip- ment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the require- ments of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 11 West 42nd

St., New York, N.Y. 10018.

High Altitudes: For altitudes/elevation above 2,000 feet ratings should be reduced at the rate of 4 percent for each 1,000 feet above sea level. Contact the manufacturer.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.

Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

The following steps will help insure that water vapor does not become a problem.

1.Be sure the heater is sized properly for the application, includ- ing ample combustion air and circulation air.

2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3.Do not use an unvented room heater as the primary heat source.

Page 6

14008-0-0403

Image 6
Contents Installation Instructions Table of Contents Important Safety Information Do not Tamper with Pilot Light Safety SystemCarbon Monoxide Poisoning MAY Lead to Death Safety Information for Users of LP-GAS LP-GAS Warning OdorAccessories IntroductionGeneral Information Before you get startedMake sure you have received all parts Clearances Provisions for Adequate Combustion & Ventilation AIRClearances Combustible Material Fireplace PreparationInstalling AS a Vented Appliance Before Fully Installing the ApplianceInstalling Damper Clamp Figure Installing a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Proper Installation Sequence LOG Grate PlacementPlacement of Glowing Embers and Lava Rock Vfsr and VFSV-16, 18, 24, 30C FigureOperation INSTRUCTIONS/FLAME Appearance Variable Figure Millivolt FigureVFSR-16, 18, 24, 30 Lighting Instructions What to do if YOU Smell GASVFSV-16, 18, 24, 30 Lighting Instructions Vfsv Pilot Pilot Flame CharacteristicsVfsr Pilot Correct Pilot Flame Pattern Incorrect Pilot Flame PatternCleaning and Servicing Turn OFF Heater and Allow to Cool Before CleaningWiring VfsrVfsv New Installation Gas odor even when control knob is in OFF positionHeater produces a whistling noise when main burner is lit Appliance produces unwanted odorsParts List Common PartsParts View HOW to Order Repair Parts Service Notes Service Notes Mail info@empirecomfort.com