GENERAL INFORMATION
This is an unvented
Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appliance. Water vapor produced by an unvented heater can create moisture problems in a home when operated for extended periods of time.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
The initial
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.
Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and replace any part of the control system and any gas control which has been under water.
Before you get started
Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not attempt to install any part of the appliance unless you have all parts in good condition.
Make sure you have received all parts:
Check your packing list to verify that all listed parts have been received. You should have the following:
•Gas log grate/burner assembly.
•Two (2) masonry anchoring screws and two (2) 10 x 1/2" black sheet metal anchoring screws.
•Plastic bag containing glowing embers (rock wool) for burner coverage.
•Plastic bag containing lava rock.
•Switch log assembly - VFSR models
•Remote kit - VFSV models
Millivolt controlled heater designed to be operated with optional devices for ON/OFF functions.
•Wall switch or thermostat with wire.
•Hand held remote control with ON/OFF switch or thermostat.
Handle the gas log burner assembly by the grate and legs only. Do not pick the unit up by the burner.
Gloves are recommended when handling logs to prevent skin irritation. Logs are fragile - Handle with care.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equip- ment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the require- ments of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
High Altitudes: For altitudes/elevation above 2,000 feet ratings should be reduced at the rate of 4 percent for each 1,000 feet above sea level. Contact the manufacturer.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a
Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.
The following steps will help insure that water vapor does not become a problem.
1.Be sure the heater is sized properly for the application, includ- ing ample combustion air and circulation air.
2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.
3.Do not use an unvented room heater as the primary heat source.
Page 6 |