Getting started
Bracket Setup for Installation
Video Out
Alarm In 1
Alarm In 2
Alarm In 3
Alarm In 4
Alarm Out 1
Alarm Out 2
AC 24V Output (for Heater connection)
Mainframe 18PIN Connector
Initial Setting
●Communication Protocol Setting (Installation Bracket)
Select and set SW1 on the installation bracket for setting the communication protocol.
SW1 | Protocol | Baud Rate (BPS) |
0 | Samsung | 9,600 |
1 | Samsung | 19,200 |
2 | 2,400 | |
3 | 4,800 | |
4 | 9,600 | |
5~F | Reserve |
|
Note) Factory Default : 0 (Samsung, 9600)
●Baud Rate Setting by DVR Model
For control of the speed dome camera using DVR without a dedicated controller, set the baud rate by DVR model as described below.
Protocol | Samsung | Pelco | |
DVR Model | |||
|
| ||
9600,19200 | 9,600 | ||
9600,19200 | 4800, 9600 | ||
9600,19200 | 2400,4800,9600 |
Note) A faster rate may degrade stability.
The control function may not be available depending on the DVR Firmware version.
Be sure to install the latest DVR Firmware version.
● Camera ID Setting (Mainframe front panel)
·Set the Camera ID using the two rotary switches. SW1 and SW2 |
|
|
refer to the lower and upper positions, respectively. |
|
|
SW2 | SW1 | |
·EX) If the camera ID is number 1, set as described below. | 0 | 1 |
|
| |
|
|
|
| SW2 | SW1 |
ENGLISH