Samsung SPD-2200 Initialize Setting ① Power On Reset, ② Factory Default Set, ③ Camera Default Set

Page 26

Camera setting

Main Menu

Camera Setting

Sequence Setting

P/T Setting

OSD Setting

Alarm Setting

Initialize

Status

Press the Enter key

Initialize

Power On Reset

Factory Default Set Camera Default Set

Auto Refresh

7Days

Main Menu

Camera Setting

Sequence Setting

P/T Setting

OSD Setting

Alarm Setting

Initialize

Status

Press the Enter key

Cam Model =22NC Cam Version=03.05 Dome Version=01.00 Con Protocol=SAMSUNG Dome ID=001

Come Mode=DUPLEX

Factory Set=ON

ENGLISH

6) Initialize Setting

Power On Reset

·Initialize a camera to the status prior to power supply

Factory Default Set

·Initialize to the factory default. Data such as preset is deleted. This function is used to initialize a variety of settings. However, the digital zoom factor is not changed.

Camera Default Set

·When a single camera module is replaced due to a defect only in that camera, Camera Default Set is used to

set the replacement camera module to the setting of the previous camera.

Auto Refresh

·Optimize the built- in electrical circuit and the status of fixtures and devices in a camera at a pre-determined interval (operating intervals can be set).

This is used for keeping, maintaining and correcting the camera settings when a camera directly faces a specific light source, or the setting is not preserved because the camera has been rotating left, right, up and down in a specific area for a long time.

The default is 7 Days. ·OFF, 1~7Days

Auto Refresh won’t run when OFF is selected. Select between 1~7 Days, and Auto Refresh will run at the selected intervals.

Auto Refresh takes less than about 10 seconds.

The message “Auto Refresh” disappears when the operation is completed.

7) Status

Displays the dome camera setting.

Cam Model =22NC

Mounted Camera Model

Cam Version=03.05

Mounted Camera S/W Version

Dome Version=01.00

Control Board S/W Version

Con Protocol=SAMSUNG

Setting Protocol

Dome ID=001

Dome Camera ID

Controller=Type1-9600

Communication Mode Setting Status

 

 

50

SPEED DOME CAMERA

SPEED DOME CAMERA

51

 

 

 

 

Image 26
Contents Operation/Programming Model Description Speed Dome CameraContents Sign Main Features Extreme high or low temperatureRotary Switch 2 SW2 Connector CablePower Switch Rotary Switch 1 SW1Getting started Bracket Setup for InstallationInitial Setting Camera ID Switch Setting RS-485 Terminal Setting Mainframe front panel Controller Model Setting Mainframe front panelFactory Default Mainframe front panel Component DescriptionCable How to InstallPower adapter cable RS-485 Communication CableWall Mounting STB-270PW Accessories optionOptions related to installation How to Install the Camera using the Embedded Housing ⑧ Fasten the lock screwMenu Configuration Camera settingOSD Menu Configuration Dome Camera Users’Menu Settings White Balance ① AWB Mode① AE Mode Exposure③ Slow Shutter ② D&N Mode Day & Night ModeMode OFF Back LightFlickerless Flickerless Mode Sequence Setting① Set Preset Sync·AUTO/MANUAL ④ Swing Focus Mode③ Tilt Swing ⑤ Group SEQ⑦ PTZ Trace ⑧ Power On Resume⑥ Tour ON/OFF T Setting① Pan Limit ② Tilt Limit⑤ Home position ④ Area Masking⑥ Smart P/T ⑦ Auto Flip④ Preset Name OSD Setting③ Preset Number ① Camera ID② Alarm Input Alarm Setting① Alarm Enable ⑤ Sequence Status·OUT1 SET/OUT2 SET ③ Alarm Out④ Motion Detection ·OUT1 TIME/OUT2 Time③ Camera Default Set Initialize Setting ① Power On Reset② Factory Default Set ④ Auto RefreshInstallation Method System configurationDimension Ceiling attached Type InstallationSpecifications Ntsc PALPreset Position Pan ResolutionTilt Resolution Alarm