Problem Determination
ida ReRouter
63
ROUT0035E: Cannot open configuration file [...]
Description: The system is not properly configured.
The configuration file "idaRoute.ini" is not created
in the idaRoute directory.
Action: Use the idaRCtrl program to make the proper setup.
Note: -
ROUT0052E: Configuration error for entry [...]
Description: A configuration error has been found - [...]
identifies the wrong keyword.
Action: Correct the entry, using the idaRCtrl.
Note: -
ROUT0104E: No reply generated from remote device [...]
Description: The printer application (e.g. HOST-PSF or
idaPSS) has requested an ACK. However, the
remote device has not answered before a timeout
has occurred.
Action: Check the connection to the remote device, reset
the device and try once more.
Note: -
ROUT0105E: APPC communication error
Description: A communication error has occurred. An invalid
or unsupported status return code is sent from
APPC API.
Action: The transaction program is terminated. To re-start
the communication, operate/re-start the printer.
If the problem persists, contact your system administrator..
Note: -
ROUT0106E: APPC allocation error [...]
Description: The transaction program has discovered an allocation
error.
Action: The TP (transaction program) is not configured in
the setup for the Communications Manager/2.
Enter CM/2 and correct the TP.
or
- no allocation is pending in the program. The
program has been started manually.
Note: -