Problem Determination ida ReRouter
ROUT0035E: | Cannot open configuration file [...] |
Description: | The system is not properly configured. |
| The configuration file "idaRoute.ini" is not created |
Action: | in the idaRoute directory. |
Use the idaRCtrl program to make the proper setup. | |
Note: | - |
ROUT0052E: | Configuration error for entry [...] |
Description: | A configuration error has been found - [...] |
Action: | identifies the wrong keyword. |
Correct the entry, using the idaRCtrl. | |
Note: | - |
ROUT0104E: | No reply generated from remote device [...] |
Description: | The printer application (e.g. |
| idaPSS) has requested an ACK. However, the |
| remote device has not answered before a timeout |
Action: | has occurred. |
Check the connection to the remote device, reset | |
Note: | the device and try once more. |
- | |
ROUT0105E: | APPC communication error |
Description: | A communication error has occurred. An invalid |
| or unsupported status return code is sent from |
Action: | APPC API. |
The transaction program is terminated. To | |
| the communication, |
| If the problem persists, contact your system administrator.. |
Note: | - |
ROUT0106E: | APPC allocation error [...] |
Description: | The transaction program has discovered an allocation |
Action: | error. |
The TP (transaction program) is not configured in | |
| the setup for the Communications Manager/2. |
| Enter CM/2 and correct the TP. |
| or |
| - no allocation is pending in the program. The |
| program has been started manually. |
Note: | - |
63