Problem Determination ida ReRouter

ROUT0618I:

Remote device (printer) is not ready

Description:

An attempt to make a connection has failed.

Action:

Check the remote device and retry.

Note:

Make sure that a test page can be ejected from

 

the remote device.

ROUT0619E:

Cannot reach the specified destination

Description:

Connection to the remote device cannot be established.

Action:

Check the IP address

 

Check that the remote device is turned on

 

Ping the remote device

Note:

-

ROUT0700E:

Internal software error [...]

Description:

An internal software error has occurred.

Action:

Retry and if the problem persists contact your

 

point of purchase.

Note:

-

ROUT0800E:

Semaphore handling error [...]

Description:

An OS/2 system call has failed.

Action:

Re-start the ida ReRouter, re-start the OS/2.

Note:

If problem persist, contact your system administrator.

-

ROUT0801E:

Named Pipe handling error [...]

Description:

An OS/2 system call has failed.

Action:

Re-start the ida ReRouter, re-start the OS/2.

Note:

If problem persist, contact your system administrator.

-

ROUT0802E:

Timer handling error [...]

Description:

An OS/2 system call has failed.

Action:

Re-start the ida ReRouter, re-start the OS/2.

Note:

If problem persist, contact your system administrator.

-

67

Page 67
Image 67
I-Data ReRouter ROUT0700E Internal software error, ROUT0800E Semaphore handling error, ROUT0801E Named Pipe handling error