INSTALLATION
GENERAL REQUIREMENTS
CAUTION:
EQUIPMENT MUST BE INSTALLED BY A QUALIFIED
HEATING PERSON.
CAUTION:
ONLY “CLASS A”
NEYS INTENDED FOR USE WITH YOUR WOOD-
CHUCK SHOULD BE USED.
FIRST AND ABOVE ALL is safety for you and your family.
MUST USE: Class A Masonry or ULC listed, manufac- tured Class A All Fuels Chimney.
RECOMMENDED SIZE: Rectangular 8"x12" or Round 8".
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. The Woodchuck is to be used in conjunction with a listed gas or oil fired furnace or as a central furnace.
ELECTRICAL SUPPLY: 115 volts, 60HZ, 1 Phase, less than 12 amps.
Install system with 0.2 static pressure.
Flue setting .06 W.C. Max to .04 W.C. Min.
Wood or coal related fires are caused almost exclu- sively by installation, operation or maintenance errors; but not by unsafe equipment.
IMPORTANT: Check with your local state and federal codes on installation at your local fire department.
PLACEMENT AND MINIMUM CLEAR-
ANCES
CAUTION:
FURNACE MUST BE INSTALLED ON A
BUSTIBLE FLOOR OR 3/8" THICK FIREPROOF MILL-
BOARD OR EQUIVALENT.
Locating your unit is very important for proper draft and most efficient heating possible. See figure 7.
FIGURE 7 LOCATING THE WOODCHUCK
15