FIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER

SLIDE FLANGES OF

CIRCULATING BLOWER

BEHIND ANGLES ON BACK

OF FURNACE

ELECTRICAL

CONNECTION BOX

FORCE FLANGE OF SUPPORT

ANGLE INTO GROOVE ON FURNACE

MOUNTING STRIP

HOLE FOR

CONDUIT

FILTER (NOT

SUPPLIED)

ACCESS DOOR

FILTER

ANGLES

BEND TABS ON SUPPORT ANGLE

OVER, BEHIND FLANGE ON FILTER

BOX, TOP & BOTTOM

GROOVE IN

FURNACE

MOUNTING STRIP,

BOTH SIDES

SUPPORT ANGLE

FIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER

ELECTRICAL HOOKUP (FIGURE 22)

1.If you have an optional temperature gauge to monitor heat exchanger temperature in your comfort control center, then the thermocouple wires must be connected to the gauge when installing the control. See figure 20.

IMPORTANT: Remove the wire ground clip from the ter- minals of the gauge and connect White wire to + termi- nal and Red wire to - terminal. See figure 22.

2.A prewired conduit is connected to the comfort con- trol center for the circulating blower. The opposite end is to be connected in the junction box on the blower motor. Connect like colored wires. Secure conduit to junction box with box connector.

3.The comfort control is factory wired to the forced draft motor (optional on Model 526). If you have the forced draft, locate a wall thermostat in the desired location of you house and run #18 thermostat wire (not furnished) from this thermostat to R and G terminals of the trans-

former in the comfort control. These connections have been routed to a terminal strip on the outside of the comfort control box for convenient connection. Make sure the “heat anticipator” on your thermostat is set at 0.3.

4.The circulating blower limit control is factory wired to the comfort control center. Jumper removed, normal fan limit control settings are 160°F ON, and 110°F OFF.

5.Route 110VAC power through conduit from your power supply to the comfort control center box. Route through box connector provided and connect hot (L1) to BLACK, Neutral to WHITE and ground to GREEN as shown on figure 22. You must provide a power discon- nect in the power supply line to your furnace which is within sight of the Woodchuck and not more than 30 feet away. Your circuit breaker at the power supply may meet these requirements.

25

Image 26
Contents Phone 715/654-5132 Fax 715/654-5513 INSTRUCTION AND PARTS BOOK FORMODELS 07/97Page INTRODUCTION TRANSPORTATION DAMAGESTABLE OF CONTENTS DANGER FURNACE SAFETYDANGER DANGERDISCLAIMER NOTICE SPECIFICATIONSMODEL MODELEFFICIENCY GENERAL INFORMATIONHIGH QUALITY CONSTRUCTION COMFORTADDITION COMFORT AND SAVING FIGURE FIGURECOMMON SENSE OPERATION PROCEDURE IN THE EVENT OF POWER FAILUREOPERATION IF YOU HAVE CHIMNEY FIRESTARTUP OPERATING YOUR WOODCHUCK FURNACEBURNING WOOD IN YOUR WOOD- CHUCK FIGURE 5 WOODCHUCK CONTROLSASH REMOVAL HELPFUL HINTSRECHARGING BURNING COAL IN YOUR WOOD- CHUCKSTARTING A COAL FIRE BANKINGASH REMOVAL MAINTENANCEOPTIONAL CATALYTIC COMBUSTOR FOR MODELS 2900/4000 SOLUTION TROUBLE SHOOTINGPROBLEM POSSIBLE CAUSEPOSSIBLE CAUSE PROBLEMSOLUTION 9. Excessive amounts ofGENERAL REQUIREMENTS INSTALLATIONPLACEMENT AND MINIMUM CLEAR ANCES FIGURE 7 LOCATING THE WOODCHUCKFIGURE 8 TYPICAL CHIMNEY CHECKLIST FIGURE 9 CHIMNEY/ROOF CLEARANCE CHIMNEY INSTALLATIONTYPICAL STOVE PIPE INSTALLATION INSTALLATION OF A BAROMETRIC DRAFT INSTALLING YOUR WOODCHUCKSTOVE PIPE INSTALLATION DAMPERS IN STOVE PIPESAIR DUCT INSTALLATION ADD-ONINSTALLATIONSFIGURE 12 PARALLEL ADD-ONINSTALLATION WOODCHUCK FINAL ASSEMBLYOPTIONAL SHAKER GRATE INSTALLATION FOR MODEL FIGURE 13 CENTRAL ADD-ONINSTALLATIONFIGURE 15 INSTALL SHAKER GRATE HANDLE INSTALL SHAKER GRATE HANDLE MODEL 2900 ONLYFIGURE 14 POOR INSTALLATIONS FIGURE 17 INSTALL FIREBRICK INSTALL FIREBRICKFIGURE 16 INSTALL OPTIONAL SHAKER GRATE FOR MODEL FIGURE 19 INSTALL MANUAL DRAFT-MODEL526 ASSEMBLE MANUAL DRAFT MODEL 526 ONLYINSTALL CIRCULATING BLOWER INSTALL FILTER BOXFIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER ELECTRICAL HOOKUP FIGUREFIGURE 22 ELECTRICAL WIRING DIAGRAM KEY NO. PART NO REPAIR PARTSBASIC UNIT FOR MODEL DESCRIPTIONDESCRIPTION BASIC UNIT FOR MODELKEY NO. PART NO KEY NO. PART NODESCRIPTION BASIC UNIT FOR MODELKEY NO. PART NO KEY NO. PART NOFILTER BOX OPTIONAL SHAKER GRATE FOR MODELSHAKER GRATE FOR MODELS 2900/4000 2900/4000KEY NO. PART NO. DESCRIPTION CIRCULATING BLOWER COMFORT CONTROLDESCRIPTION PERSONAL DATA INFORMATION FOR FUTURE REFERENCE Page LIMITED WARRANTY