ADDITION COMFORT AND SAVING

enough to operate properly in mild weather, it will not be large enough to keep the house

warm in cold weather. This could cause the furnace to overheat and a loss of heat up the chimney. The result then is a compromise which is neither efficient or com- fortable. Woodchuck furnaces, however, have a three speed circulation blower which can be adjusted via a three position rotary switch on the Comfort Control Center. This allows the user to select the blower speed to meet the air movement requirements of the installa- tion. In addition, when the weather is mild and the fur- nace is operating at a lower output, the blower can be set on low to gently move the air. Similarly, when it is cold and the furnace is operated at higher levels of heat, output can be switched to higher speeds.

But how can all this improve the efficiency of your home? As figure 1 illustrates, heated air rises away from the living area and stratifies. This causes large temperature differentials between the ceiling where heat is lost rapidly through conduction and the floor where children often play. By allowing for continuous air movement, even during periods of low heat output, this stratification is not allowed to take place. You are

more comfortable and lose less heat through your ceil- ings as illustrated in figure 2.

This situation can be especially troublesome in multi-level homes as illustrated in figure 3. As soon as the blower shuts off, the air in the home begins to strat- ify; warm air rising to the upper levels and cool air col- lecting in the lower levels. The lower levels become increasingly uncomfortable until the blower turns on again. Unfortunately, the upper levels are still warm so they become uncomfortably warm before the blower turns off. By allowing for a steadier, more continuous operation of the blower the entire house stays at a more constant and comfortable level, figure 4.

ADDITION COMFORT AND SAVING

Options are available for your Woodchuck furnace, and one of these deserve special mention. The Aqua-Si- phon is capable of pre-heating your domestic water free of charge during the heating season for additional saving to you.

WASTED HEAT

ZONE

82° THERMOSTAT

COMFORT ZONE

74°

DISCOMFORT ZONE

60°

FIGURE 1

75°

THERMOSTAT

74°

73°

FIGURE 2

UNCOMFORTABLY HOT

UNCOMFORTABLY COLD

FIGURE 3

FIGURE 4

7

Image 8
Contents INSTRUCTION AND PARTS BOOK FOR MODELSPhone 715/654-5132 Fax 715/654-5513 07/97Page INTRODUCTION TRANSPORTATION DAMAGESTABLE OF CONTENTS FURNACE SAFETY DANGERDANGER DANGERSPECIFICATIONS MODELDISCLAIMER NOTICE MODELGENERAL INFORMATION HIGH QUALITY CONSTRUCTIONEFFICIENCY COMFORTADDITION COMFORT AND SAVING FIGURE FIGUREOPERATION PROCEDURE IN THE EVENT OF POWER FAILURE OPERATIONCOMMON SENSE IF YOU HAVE CHIMNEY FIREOPERATING YOUR WOODCHUCK FURNACE BURNING WOOD IN YOUR WOOD- CHUCKSTARTUP FIGURE 5 WOODCHUCK CONTROLSASH REMOVAL HELPFUL HINTSBURNING COAL IN YOUR WOOD- CHUCK STARTING A COAL FIRERECHARGING BANKINGASH REMOVAL MAINTENANCEOPTIONAL CATALYTIC COMBUSTOR FOR MODELS 2900/4000 TROUBLE SHOOTING PROBLEMSOLUTION POSSIBLE CAUSEPROBLEM SOLUTIONPOSSIBLE CAUSE 9. Excessive amounts ofINSTALLATION PLACEMENT AND MINIMUM CLEAR ANCESGENERAL REQUIREMENTS FIGURE 7 LOCATING THE WOODCHUCKFIGURE 8 TYPICAL CHIMNEY CHECKLIST FIGURE 9 CHIMNEY/ROOF CLEARANCE CHIMNEY INSTALLATIONTYPICAL STOVE PIPE INSTALLATION INSTALLING YOUR WOODCHUCK STOVE PIPE INSTALLATIONINSTALLATION OF A BAROMETRIC DRAFT DAMPERS IN STOVE PIPESAIR DUCT INSTALLATION ADD-ONINSTALLATIONSWOODCHUCK FINAL ASSEMBLY OPTIONAL SHAKER GRATE INSTALLATION FOR MODELFIGURE 12 PARALLEL ADD-ONINSTALLATION FIGURE 13 CENTRAL ADD-ONINSTALLATIONFIGURE 15 INSTALL SHAKER GRATE HANDLE INSTALL SHAKER GRATE HANDLE MODEL 2900 ONLYFIGURE 14 POOR INSTALLATIONS FIGURE 17 INSTALL FIREBRICK INSTALL FIREBRICKFIGURE 16 INSTALL OPTIONAL SHAKER GRATE FOR MODEL FIGURE 19 INSTALL MANUAL DRAFT-MODEL526 ASSEMBLE MANUAL DRAFT MODEL 526 ONLYINSTALL CIRCULATING BLOWER INSTALL FILTER BOXFIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER ELECTRICAL HOOKUP FIGUREFIGURE 22 ELECTRICAL WIRING DIAGRAM REPAIR PARTS BASIC UNIT FOR MODELKEY NO. PART NO DESCRIPTIONBASIC UNIT FOR MODEL KEY NO. PART NODESCRIPTION KEY NO. PART NOBASIC UNIT FOR MODEL KEY NO. PART NODESCRIPTION KEY NO. PART NOOPTIONAL SHAKER GRATE FOR MODEL SHAKER GRATE FOR MODELS 2900/4000FILTER BOX 2900/4000KEY NO. PART NO. DESCRIPTION CIRCULATING BLOWER COMFORT CONTROLDESCRIPTION PERSONAL DATA INFORMATION FOR FUTURE REFERENCE Page LIMITED WARRANTY