Johnson Controls YP8C/YPLC*MP, LP8C/LPLC*MP Seconds For Size of Test Dial Revolution Cu Ft

Page 24

368262-UIM-B-1008

Table 10: Gas Rate (CU FT/HR) at Full Input

Seconds For

 

Size of Test Dial

 

1 Revolution

1 Cu Ft

 

2 Cu Ft

 

5 Cu Ft

10

360

 

720

 

1800

11

327

 

655

 

1636

12

300

 

600

 

1500

13

277

 

555

 

1385

14

257

 

514

 

1286

15

240

 

480

 

1200

16

225

 

450

 

1125

17

212

 

424

 

1059

18

200

 

400

 

1000

19

189

 

379

 

947

20

180

 

360

 

900

21

171

 

343

 

857

22

164

 

327

 

818

23

157

 

313

 

783

24

150

 

300

 

750

25

144

 

288

 

720

26

138

 

277

 

692

27

133

 

267

 

667

28

129

 

257

 

643

29

124

 

248

 

621

30

120

 

240

 

600

31

116

 

232

 

581

32

113

 

225

 

563

33

109

 

218

 

545

34

106

 

212

 

529

35

103

 

206

 

514

36

100

 

200

 

500

37

97

 

195

 

486

38

95

 

189

 

474

39

92

 

185

 

462

40

90

 

180

 

450

41

88

 

176

 

439

42

86

 

172

 

429

43

84

 

167

 

419

44

82

 

164

 

409

45

80

 

160

 

400

46

78

 

157

 

391

47

76

 

153

 

383

48

75

 

150

 

375

49

73

 

147

 

367

50

72

 

144

 

360

51

71

 

141

 

355

52

69

 

138

 

346

53

68

 

136

 

340

54

67

 

133

 

333

Seconds For

 

Size of Test Dial

 

1 Revolution

1 Cu Ft

 

2 Cu Ft

 

5 Cu Ft

55

65

 

131

 

327

56

64

 

129

 

321

57

63

 

126

 

316

58

62

 

124

 

310

59

61

 

122

 

305

60

60

 

120

 

300

62

58

 

116

 

290

64

56

 

112

 

281

66

54

 

109

 

273

68

53

 

106

 

265

70

51

 

103

 

257

72

50

 

100

 

250

74

48

 

97

 

243

76

47

 

95

 

237

78

46

 

92

 

231

80

45

 

90

 

225

82

44

 

88

 

220

84

43

 

86

 

214

86

42

 

84

 

209

88

41

 

82

 

205

90

40

 

80

 

200

92

39

 

78

 

196

94

38

 

76

 

192

96

38

 

75

 

188

98

37

 

74

 

184

100

36

 

72

 

180

102

35

 

71

 

178

104

35

 

69

 

173

106

34

 

68

 

170

108

33

 

67

 

167

110

33

 

65

 

164

112

32

 

64

 

161

116

31

 

62

 

155

120

30

 

60

 

150

124

29

 

58

 

145

128

28

 

56

 

141

133

27

 

54

 

135

138

26

 

52

 

130

144

25

 

50

 

125

150

24

 

48

 

120

157

23

 

46

 

115

164

22

 

44

 

110

171

21

 

42

 

105

180

20

 

40

 

100

24

Johnson Controls Unitary Products

Image 24
Contents Section I Safety ModelsList of Sections List of FiguresSpecific Safety Rules and Precautions Safety RequirementsAnce to a 50 HZ Power Supply or a Voltage Above 130 Volts Combustion AIR Quality List of Contaminants Codes and StandardsInspection Furnace Location and ClearancesFloor Base and Ductwork Installation Downflow Section II DuctworkDuctwork General Information Duct FlangesDownflow Duct Connectors Bottom Return and Attic InstallationsAttic Installation Suspended Furnace / Crawl Space InstallationCoil Installation COIL/FURNACE Assembly MC/FC/PC Series CoilsDownflow Application Furnace Assembly MC & FC Series Coils Coil Flange InstallationFurnace Assembly MC Series Coils only Furnace Assembly PC Series CoilsFilter Installation Attempt to install filters inside the furnaceSection III Filters Side ReturnGAS Safety GAS Piping InstallationSection IV GAS Piping Horizontal FiltersSection V Electrical Power Electrical Power ConnectionsGAS Conversion for Propane LP High Altitude Natural GAS Orifice ConversionLOW Voltage Control Wiring Connections Supply Voltage ConnectionsAIR Conditioner Connections Max OutletThermostat ID ModelsModulating TWO Stage AIR Furnace Conditioner UIM-B-1008 Modulating Furnace OD Models Single Stage Heat PumpThermostat Modulating Furnace TWO Stage Heat PumpSection VI Vent System FAN-ASSISTED Combustion System Ambient Combustion Air SupplyCombustion Air Source From Outdoors Dampers, Louvers and Grilles Canada OnlyVent and Supply Outside Air Safety Check Procedure Air Supply Openings and DuctsVentilated Combustion Air Section VII START-UP Adjustments NOx Screen Removal Lo-NOx Models OnlyGAS Piping Leak Check Setup Test Mode Calculating the Furnace Input Natural GASSeconds For Size of Test Dial Revolution Cu Ft Seconds ForRevolution Cu Ft Adjustment of Manifold GAS Pressure Adjustment of Temperature RiseAdjustment of FAN Control Settings EAC060A12 080B12 Jumper Settings 080C16100C20 Section Viii Safety Controls Section IX Normal Operation and Diagnostics Furnace Control DiagnosticsNormal Operation Sequence Section X Replacement Parts List Diagnostic Fault Code Storage and RetrievalFabricated Parts Section XI Wiring Diagram Wiring DiagramJohnson Controls Unitary Products York Drive Norman, OK