WIRING DIAGRAMS | GMH95[0453,0704,0905]*XAB |
| GMH95[0703,0904,1155]*XAC |
|
|
| 24 VAC |
| OR |
|
| BLOWER |
|
|
|
|
|
| COMPARTMENT | ||
|
|
| HUMIDIFIER |
|
|
| GY | |
|
|
|
|
|
| DOOR SWITCH | ||
|
|
|
|
|
|
| ||
|
|
| 24 VAC |
|
|
|
| (OPEN WHEN |
|
|
|
|
|
|
| DOOR OPEN) | |
24V THERMOSTAT |
| 115 VAC |
|
|
|
|
| |
|
|
|
|
|
|
| ||
CONNECTIONS |
|
|
|
|
|
|
|
|
C | G | R | W Y |
| WH |
|
|
|
|
|
|
| BK |
|
| BK | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| BK |
|
|
| FUSE |
|
|
|
| OR |
|
|
|
|
|
|
| GY | |
|
|
|
|
|
|
|
| |
|
|
|
|
| 3 | 2 | 1 | PK |
|
|
|
| HUMIDIFIER |
| INTEGRATED | |
|
|
|
|
|
|
| CONTROL MODULE |
|
|
| TR (6) |
| GND |
| |
|
|
| GND (8) |
|
| ||
|
|
|
|
|
| C | |
|
|
| MVC (9) |
|
|
| |
|
|
|
|
|
| GAS | |
|
|
| MVH (12) |
|
| HI VALVE | |
|
|
|
|
| PM | ||
|
|
| MVL(2) |
|
| C | |
| C |
| NO |
| ID BLOWER | ||
|
|
|
|
| |||
|
|
| FRONT COVER |
|
| ||
|
|
|
|
| PRESSURE | ||
24V |
|
| PRESSURE SWITCH |
| SWITCH | ||
G |
| PS (10) |
|
| C | NO | |
THERMOSTAT | Y | TO | PSO (4) |
|
|
|
|
| MICRO | HLI (7) |
|
|
|
| |
|
|
|
|
|
| ||
W |
| HLO (1) |
|
|
|
| |
|
|
|
|
|
|
|
| INTEGRATED | ||||
|
| CONTROL |
| |||
|
|
| MODULE |
| ||
|
| ON OFF |
| |||
|
|
|
|
| 2ND |
|
|
|
|
|
|
| |
|
|
|
|
| STAGE | * |
|
|
|
|
| DELAY | |
|
|
|
|
| ||
|
|
|
|
| MODE * | |
|
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
| HEAT |
|
|
|
|
|
| OFF |
|
|
|
|
|
| DELAY |
|
|
|
|
|
| * | |
| FACTORY SETTINGS | |||||
SHOWN |
|
6 9 12
GY
OR
FS
5 | 4 |
| OR |
8 | 7 |
| BL |
|
|
| GR |
11 | 10 |
| YL |
| OR |
| OR |
|
|
| |
RD |
| BR | |
|
| ||
| GY |
|
|
| TERMINALS | 115 VAC | WH |
|
|
CONNECTIONS | R | RO2 (11) |
| ||
| RO1 (5) | |
|
| |
| TH (3) | 24 VAC |
|
| 40 VA |
|
| TRANSFORMER |
| 115 VAC |
DIAGNOSTIC* | NOTE 6 | XFMR | 2 |
SEE |
|
| |
LED |
|
| |
115 VAC HOT AND PARK TERMINALS | 1 | ||
|
| ||
| SEE |
| |
GND |
|
| |
NOTE 4 |
|
|
| NEUTRAL | WH | PK | |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| BK |
|
|
FLAME SENSOR |
FS |
HOT SURFACE |
IGNITER |
IGN |
HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
| WH |
| WH |
| OR GR RD |
| BK (HI) |
| YL | ||
| BL (MED) | RD | PK |
|
|
|
|
|
|
| |
| OR (MED LOW) |
|
|
|
|
| RD (LOW) |
| BK | BL | GY OR |
|
|
| |||
BR |
|
|
| ||
BR |
| WH | OR | BR | |
|
| YL |
|
| |
| CAPACITOR |
|
|
|
|
INTEGRATEDCONTROL MODULE |
|
|
| ID | LINE NEUTRALS | INTEGRATEDCONTROL MODULE |
IND |
|
| BLWR | |||
|
|
| ||||
H | L |
| ||||
| O | |||||
E |
|
| ||||
| A |
| ||||
|
| T- | ||||
|
|
| H | |||
| CIRCULATOR | |||||
I |
|
| BLWR | |||
H |
|
|
| |||
|
|
|
|
BLOWER COMPARTMENT | PU |
| ||
|
| |||
BURNER COMPARTMENT | MANUAL RESET |
| ||
AUXILIARY LIMITS |
| |||
|
|
|
| |
| GND |
| (1) IN UPFLOW |
|
|
| BLOWER DECK |
| |
|
|
|
| |
|
| BK | (2) IN C'FLOW |
|
|
| BLOWER HOUSING |
| |
|
| WH | WH |
|
|
| INDUCED DRAFT |
|
|
|
| BLOWER | WH |
|
|
|
|
| |
|
|
| PU |
|
|
|
| BL |
|
RD | OR | YL | OR |
|
|
| |||
| N | C | PK | RD |
| O |
| ||
WH |
| |||
|
|
|
| ELECTRONIC |
AIR CLEANER | |
| |
| |
| JUNCTION BOX |
DOOR |
|
SWITCH |
|
| DISCONNECT |
L | GND | N |
TO 115VAC/ 1Ø /60 HZ POWER SUPPLY WITH | ||
OVERCURRENT PROTECTION DEVICE |
ID BLOWER |
|
|
|
|
|
|
| BL | JUNCTION |
|
PRESSURE | 24 VAC |
|
|
|
|
|
| |||
|
|
|
|
| BOX |
| ||||
SWITCH | HUMIDIFIER |
|
|
| FRONT COVER |
|
|
| ||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
2 CIRCUIT | PM |
| GY | C | N | PRESSURE SWITCH |
|
| N | |
1 | O |
| GY |
| WH | |||||
CONNECTOR |
|
|
|
|
| GND | GR |
|
| GND |
|
|
|
|
|
|
|
| |||
HOT | C | 2 | BR |
|
|
|
|
| BK | L |
SURFACE |
|
|
|
|
| |||||
IGNITER | HI | 3 |
|
| OR |
|
|
| FLAME |
|
GAS VALVE |
|
|
| SENSOR |
| |||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
0
1 2 3 4 5 6 7 8 C
STEADY ON = NORMAL OPERATION | ||
OFF | = CONTROL FAILURE | |
1 FLASH | = |
|
| ||
| ||
2 FLASHES = PRESSURE SWITCH STUCK CLOSED | ||
3 FLASHES = PRESSURE SWITCH STUCK OPEN | ||
4 FLASHES = OPEN HIGH LIMIT | ||
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE | ||
6 FLASHES = | ||
7 FLASHES = LOW FLAME SIGNAL | ||
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING | ||
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY |
LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL
INTERNAL TO INTEGRATED CONTROL
PLUG CONNECTION
EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.)
OVERCURRENT PROT. DEVICE
COLOR CODES: | PK PINK | NOTES: | |
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. | |||
YL YELLOW | BR BROWN | ||
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. | |||
OR ORANGE | WH WHITE | 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL | |
PU PURPLE | BL BLUE | HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY. | |
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED | |||
GN GREEN | GY GRAY | ||
BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED. | |||
BK BLACK | RD RED | ||
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. | |||
|
| ||
0140F00592 REV. A | 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN | ||