PRODUCT IDENTIFICATION

PRODUCT IDENTIFICATION

The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.

G045 3 A  X  A  AHIGH VOLTAGE! MManual backgroundManual backgroundH Manual backgroundManual background95

Brand:

G: Goodman

Air Flow Direction

M:Upflow/Horizontal

D:Dedicated Downflow

C:Downflow/Horizontal

H:Hi Air Flow

Description

H: Dual$aver, Multi Speed

V: Two Stage/Variable Speed

AFUE

9: 90% 95: 95%

KBTUH

045: 45,000

070: 70,000

090: 90,000

115: 115,000

140: 140,000

045Manual backgroundManual background 3 Manual backgroundManual backgroundA Manual backgroundManual background X Manual backgroundManual background A Manual backgroundManual background A

Minior

Revision

A: Revision

Major Revision

A: Initial Release

NOx

N: Natural Gas

X: Low NOx

Cabinet Width

A: 14"

B: 17 1/2"

C: 21"

D: 24 1/2"

Maximum CFM @ 0.5" ESP

3:1200

4:1600

5:2000

WARNING

HIGH VOLTAGE!

Disconnect ALL power before servicing or installing this unit. Multiple power

 

sources may be present. Failure to do so may cause property damage, personal

 

injury or death.

 

 

WARNING

Goodman will not be responsible

 

for any injury or property damage

arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.

Installation and repair of this unit Manual background WARNING should be performed ONLY by individuals meeting the require- ments of an "entry level technician", at a minimum, as

specified by the Air-Conditioning, Heating, and Refrigera- tion Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.

2

Image 2
Contents GMH95 40 95% Gas Furnace TECHNICAL MANUALHIGH VOLTAGE 0453 A X A APRODUCT IDENTIFICATION GMH950904CXA GMH950905DXA GMH951155DXA PRODUCT IDENTIFICATIONGMH950453BXA GMH950703BXA GMH950704CXA General Operation PRODUCT DESIGNAccessibility Clearances Minimum Location ConsiderationsCOMPONENT IDENTIFICATION Upflow/HorizontalCabinet Size GMH95*****XACOMPONENT IDENTIFICATION PRODUCT DESIGN T.O.D. PRIMARY LIMITAUXILIARY LIMIT SWITCHES PRODUCT DESIGNPRODUCT DESIGN Coil Matches1824 EXPANSIONPRODUCT DESIGN ThermostatsFilters Disposable Minimum Filter Area in2FURNACE SPECIFICATIONS GMH95BLOWER PERFORMANCE SPECIFICATIONS BLOWER PERFORMANCEPERFORMANCE SPECIFICATIONS BLOWERGMH950703,0904,1155*XAC WIRING DIAGRAMSGMH950453,0704,0905*XAB 0140F00592 REV. AWIRING DIAGRAMS GMH950453,0704,0905*XACGMH950703,0904,1155*XAD INSTALLING THIS FAILURE TO INJURY OR DEATH