BLOWER PERFORMANCE SPECIFICATIONS
BLOWER PERFORMANCE
(CFM & Temperature Rise vs. External Static Pressure)
Model |
| Tons AC |
|
|
| EXTERNAL STATIC PRESSURE (Inches Water Column) |
|
| ||||||||||||||
Motor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Heating Speed | at 0.5" | 0.1 |
|
| 0.2 |
| 0.3 |
| 0.4 |
| 0.5 |
| 0.6 |
| 0.7 | 0.8 | ||||||
|
|
|
|
|
|
|
| |||||||||||||||
(As Shipped ) | Speed | ESP | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | CFM | CFM | |||||||
| HIGH | 3.0 | 1352 |
|
| 1318 |
| 1260 |
| 1202 |
| 1128 |
| 1044 |
| 955 | 853 | |||||
GKS90453BX* | MED | 2.5 | 1214 |
|
| 1172 |
| 1123 |
| 1064 |
| 1012 |
| 938 |
| 859 | 741 | |||||
(LOW) | 2.0 | 997 |
|
| 994 |
| 960 |
| 35 | 923 |
| 36 | 884 |
| 38 | 817 |
| 741 | 611 | |||
| LOW | 1.5 | 757 |
| 44 |
| 753 |
| 44 | 734 |
| 45 | 704 |
| 47 | 674 |
| 49 | 620 |
| 524 | 438 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 3.0 | 1449 |
| 36 |
| 1409 |
| 37 | 1326 |
| 39 | 1273 |
| 41 | 1201 |
| 43 | 1194 |
| 1136 | 1018 |
GKS90703BX* | MED | 2.5 | 1192 |
| 43 |
| 1172 |
| 44 | 1141 |
| 45 | 1094 |
| 47 | 1046 |
| 49 | 973 |
| 904 | 793 |
2.0 | 981 |
| 53 |
| 962 |
| 54 | 943 |
| 55 | 917 |
| 56 | 888 |
| 58 | 830 |
| 764 | 665 | ||
| LOW | 1.5 | 750 |
|
| 730 |
| 714 |
| 692 |
| 657 |
| 620 |
| 570 | 502 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 4.0 | 2069 |
|
| 1965 |
| 1871 |
| 1756 |
| 1661 |
| 1549 |
| 1415 | 1275 | |||||
GKS90704CX* | MED | 3.5 | 1752 |
|
| 1724 |
| 1667 |
| 1603 |
| 1488 |
| 35 | 1402 |
| 1290 | 1082 | ||||
(LOW) | 3.0 | 1437 |
| 36 |
| 1437 |
| 36 | 1417 |
| 36 | 1369 |
| 38 | 1320 |
| 39 | 1256 |
| 1140 | 984 | |
| LOW | 2.5 | 1184 |
| 44 |
| 1177 |
| 44 | 1161 |
| 44 | 1132 |
| 46 | 1095 |
| 47 | 1047 |
| 928 | 837 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 4.0 | 1970 |
|
| 1874 |
| 35 | 1757 |
| 38 | 1667 |
| 40 | 1566 |
| 42 | 1431 |
| 1334 | 1182 | |
GKS90904CX* | MED | 3.5 | 1713 |
| 39 |
| 1650 |
| 40 | 1572 |
| 42 | 1510 |
| 44 | 1418 |
| 47 | 1313 |
| 1211 | 1079 |
3.0 | 1439 |
| 46 |
| 1412 |
| 47 | 1370 |
| 48 | 1327 |
| 50 | 1260 |
| 53 | 1166 |
| 1078 | 956 | ||
| LOW | 2.5 | 1183 |
| 56 |
| 1155 |
| 57 | 1122 |
| 59 | 1108 |
| 60 | 1062 |
| 62 | 1011 |
| 931 | 816 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 5.0 | 2147 |
|
| 2114 |
| 2057 |
| 2030 |
| 1978 |
| 1889 |
| 1784 | 1713 | |||||
GKS90905DX* | MED | 4.0 | 1675 |
| 40 |
| 1686 |
| 1640 |
| 40 | 1623 |
| 41 | 1557 |
| 43 | 1501 |
| 1455 | 1360 | |
3.5 | 1489 |
| 45 |
| 1470 |
| 45 | 1436 |
| 46 | 1409 |
| 47 | 1361 |
| 49 | 1318 |
| 1243 | 1130 | ||
| LOW | 3.0 | 1307 |
| 51 |
| 1265 |
| 52 | 1234 |
| 54 | 1203 |
| 55 | 1168 |
| 57 | 1096 |
| 1053 | 991 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 5.0 | 2134 |
| 40 |
| 2103 |
| 40 | 2029 |
| 42 | 1941 |
| 44 | 1906 |
| 44 | 1818 |
| 1733 | 1625 |
GKS91155DX* | MED | 4.0 | 1678 |
| 51 |
| 1643 |
| 52 | 1643 |
| 52 | 1577 |
| 54 | 1527 |
| 56 | 1489 |
| 1423 | 1339 |
3.5 | 1453 |
| 58 |
| 1440 |
| 59 | 1426 |
| 59 | 1363 |
| 62 | 1349 |
| 63 | 1314 |
| 1253 | 1205 | ||
| LOW | 3.0 | 1259 |
| 67 |
| 1239 |
| 68 | 1220 |
| 70 | 1181 |
| 1159 |
| 1118 |
| 1082 | 1015 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed.
2.All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed.
3.For most jobs, about 400 CFM per ton when cooling is desirable.
4.INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
5.The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for air conditioning purposes only.
6 The dashed
7.The above chart is for U.S. furnaces installed at
12