Goodman Mfg GKS9 service manual

Page 6

COMPONENT IDENTIFICATION

GKS9

1 1/2

1 5/8

1

AIR

DISCHARGE

20 13/16

HIGH VOLTAGE

ELECTRICAL HOLE

LEFT SIDE

DRAIN LINE HOLES

LOW VOLTAGE

ELECTRICAL HOLE

SIDE CUT-OUT

22 1/16

UNFOLDED FLANGES

23 9/16

FOLDED FLANGES

AIR

INTAKE

PIPE

2" PVC

A

B (DISCHARGE)

C

CONDENSATE

DRAIN TRAP

w/ 3/4" PVC DISCHARGE (RIGHT OR LEFT SIDE)

2

UNFOLDED FLANGES

FOLDED FLANGES

AIR

DISCHARGE

 

STANDARD GAS

 

SUPPLY HOLE

 

HIGH VOLTAGE

 

ELECTRICAL HOLE

 

RIGHT SIDE

DRAIN

DRAIN LINE

HOLES

TRAP

 

LOW VOLTAGE

ELECTRICAL HOLE

SIDE CUT-OUT

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

 

 

 

 

 

 

Cabinet Size

A

B

C

D

E

 

 

 

 

 

 

 

 

 

 

 

 

GKS90453BX*

17-1/2

16

12-15/16

12-1/8

13-5/8

GKS90703BX*

 

 

 

 

 

 

 

 

 

 

 

GKS90704CX*

21

19-1/2

15-15/16

16

17-1/2

GKS90904CX*

 

 

 

 

 

 

 

 

 

 

 

GKS90905DX*

24-1/2

23

20-7/16

19-3/8

20-7/8

GKS91155DX*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches.

NOTE: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues.

6

Image 6
Contents Technical Manual 045 Product IdentificationDo not connect or use any device Product Design General OperationComponent Identification Compartment Burner BlowerGKS9 Pressure Switch Trip Points and Usage Chart Rollout Limit Switches Auxiliary Limit SwitchesD. Primary Limit 1824 Side Return Bottom ReturnFurnace Specifications Model GKS9Blower Performance Specifications Blower PerformancePerformance Specifications Wiring Diagrams GKS9*****X