Johnson Controls GGLS*MP, TGLS*MP, TG8S*MP Johnson Controls Unitary Products York Drive Norman, OK

Page 30

NOTES

Subject to change without notice. Published in U.S.A.

356485-UIM-G-1211

Copyright © 2011 by Johnson Controls, Inc. All rights reserved.

Supersedes: 356485-UIM-F-0910

Johnson Controls Unitary Products

5005 York Drive

Norman, OK 73069

Image 30
Contents List of Figures Section I SafetyList of Sections List of TablesSpecific Safety Rules and Precautions Safety RequirementsAnce to a 50 HZ Power Supply or a Voltage Above 130 Volts Combustion AIR Quality List of Contaminants Codes and StandardsInspection Furnace Location and ClearancesDirectly BELOW. Keep Clear of ALL OBSTRUC- Tions Section II Ductwork Floor Base and Ductwork Installation DownflowCoil Installation Ductwork General InformationCoil Flange Installation COIL/FURNACE Assembly MC/FC/PC Series CoilsFurnace Assembly MC & FC Series Coils Furnace Assembly PC Series CoilsBottom Return and Attic Installations Coil / Furnace Assembly HC Series CoilsDownflow Duct Connectors Attic InstallationSuspended Furnace / Crawl Space Installation Typical Suspended Furnace / Crawl Space InstallationSection III Filters Filter InstallationAttempt to install filters inside the furnace Btuh kWSection IV GAS Piping GAS SafetyGAS Piping Installation Side ReturnHigh Altitude GAS Orifice Conversion High Altitude Pressure Switch ConversionGAS Orifice Conversion for Propane LP Manifold Pressures in wcLOW Voltage Control Wiring Connections Section V Electrical PowerElectrical Power Connections Supply Voltage ConnectionsID Models ThermostatSingle Stage PSC AIR Furnace Conditioner Single Stage PSC Furnace OD ModelsSingle Stage Heat Pump Section VI Twinning and Staging Section VII Vent System StagingVent Connections Venting Into AN Existing Chimney Category 1 450 F. MAX. Vent TempVenting FAN-ASSISTED Combustion SystemVentilated Combustion Air Vent and Supply Outside Air Safety Check ProcedureAir Supply Openings and Ducts Free AreaSection Viii START-UP Adjustments NOx Screen Removal Lo-NOx Models OnlyGAS Piping Leak Check Ignition System SequenceCalculating the Furnace Input Natural GAS Revolution Cu Ft Seconds ForRevolution Read the manifold gas pressure Adjustment of Manifold GAS Pressure & Input RateRead the inlet gas pressure Nominal Manifold PressureAdjustment of Temperature Rise Adjustment of FAN Control SettingsManifold Pressure U Tube Connection Bottom Airflow Data Scfm 1086 971 843 521 060A10 Medium High 1249 1207 757 733 694 659 575 444 399707 684 641 604 495 397 282 High 1371 1323 1251 1098 1018 921 669 503Section IX Safety Controls Furnace Control Diagnostics Section X Replacement Parts List Diagnostic Fault Code Storage and RetrievalSection XI Wiring Diagram Wiring DiagramJohnson Controls Unitary Products York Drive Norman, OK

TG8S*MP, GG8S*MP, TGLS*MP, GGLS*MP specifications

Johnson Controls is a leader in the development of innovative building management solutions, and its product line encompassing the GGLS*MP, TGLS*MP, TG8S*MP, and GG8S*MP series exemplifies this commitment to excellence. These devices are designed to optimize energy efficiency, enhance occupant comfort, and ensure seamless integration into commercial building infrastructures.

The GGLS*MP series focuses on the integration of advanced sensors and controllers that facilitate effective lighting and HVAC management. With built-in capabilities for occupancy sensing and daylight harvesting, these devices can automatically adjust settings based on real-time conditions. Their energy-efficient operation not only contributes to lower utility costs but also supports sustainability goals, making them ideal for modern green buildings.

In contrast, the TGLS*MP series emphasizes the importance of temperature regulation and comfort in residential or smaller commercial settings. These controllers utilize advanced algorithms to maintain optimal indoor climates, adjusting heating and cooling outputs in response to ambient conditions. The intuitive user interface makes it easy for users to customize their settings, providing enhanced comfort without sacrificing energy efficiency.

The TG8S*MP series is particularly renowned for its robust communication features. These devices support multiple communication protocols, allowing them to integrate smoothly with existing building management systems. This versatility ensures that customers can leverage their current infrastructure while benefiting from new technology. Additionally, the TG8S*MP includes remote monitoring capabilities, enabling facility managers to track performance metrics and troubleshoot issues from anywhere.

Lastly, the GG8S*MP series brings together security and control features, ensuring that buildings are not only energy-efficient but also secure. With capabilities for access control and monitoring, these devices provide a comprehensive solution for managing facility safety. Their integration with lighting and HVAC systems further enhances overall efficiency, creating a comfortable and secure environment for all occupants.

In summary, Johnson Controls’ GGLS*MP, TGLS*MP, TG8S*MP, and GG8S*MP series presents cutting-edge technologies designed for energy efficiency, ease of use, and versatility. By focusing on comprehensive building management, these products provide optimal performance that aligns with sustainability objectives while enhancing comfort and security. Whether in commercial or residential settings, Johnson Controls continues to lead the way in the intelligent building sector.