OPERATION

OPERATION

COMMON SENSE

Please read the following before firing your furnace. It is most important that you follow these suggestions and limitations in order to maintain your warranty and guar- antee the long life of your furnace.

NOTE: Smoke detectors and fire extinguishers should always be a part of your equipment.

This furnace is an airtight unit designed to burn 6-8 hours per load of wood or coal. If the furnace is being fired hot constantly with full flames and operating at only 2-4 hour burn cycles, it may be over fired. Your home heating needs may be too great for the size of furnace you have purchased. Your furnace can be dam- aged if fired at extremely high temperatures.

Forced firing or abuse can be detected upon inspection

AND WILL VOID YOUR WARRANTY.

COMMON SENSEDANGER:

RISK OF FIRE OR EXPLOSION. DO NOT BURN GAR- BAGE, GASOLINE, DRAIN OIL, OR OTHER FLAMMA- BLE LIQUIDS. FAILURE TO HEED MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

! IF YOU HAVE CHIMNEY FIRE !DANGER:

NEVER USE CHEMICALS OR FLUIDS SUCH AS GASOLINE, CHARCOAL LIGHTER FLUID, DRAIN OIL, FUEL OIL OR KEROSINE TO LIGHT A FIRE IN YOUR WOODCHUCK. FAILURE TO HEED MAY RE- SULT IN SERIOUS PERSONAL INJURY OR DEATH.

OPERATION PROCEDURE IN THECAUTION:

￿RISK OF FIRE

￿DO NOT OPERATE WITH FUEL LOADING OR ASH REMOVAL DOORS OPEN.

￿DO NOT STORE FUEL OR OTHER COMBUSTI- BLE MATERIAL WITHIN MARKED INSTALLATION CLEARANCES.

￿INSPECT AND CLEAN FLUES AND CHIMNEY REGULARLY.

￿UNDER CERTAIN CONDITIONS OF USE, CREO- SOTE BUILDUP MAY OCCUR RAPIDLY.

￿WAIT 10 SEC. ON FIRST LATCH BEFORE RE- FUELING.

￿LOAD FUEL CAREFULLY OR DAMAGE MAY RE- SULT.

! IF YOU HAVE CHIMNEY FIRE !

Meyer Mfg. Corp. recommends the following actions:

1.Shut any doors and air inlet dampers and draft con- trol. This should take no longer than a few seconds.

CLOSED

2. Alert everyone in the house.

3. Call the fire department.

MANUAL DRAFT

NOTE: Emptying a large box of baking soda will slow down the fire in your Woodchuck.

Keeping your chimney and stove pipe clean is the best insurance against chimney fires.

! IMPORTANT !

OPERATION PROCEDURE IN THE

EVENT OF POWER FAILURE:

Your Woodchuck can operate and produce heat without electric power. This is one of the features built into ev- ery Woodchuck.

The following steps should be taken in the event of an electrical power failure:

1. Locate all heating duct dampers (not smoke pipe

damper), if any, to open position.

CLOSED

2. Turn manual draft controls to this position.

Ash door should never be used

MANUAL DRAFT

in power failure.

 

 

 

 

3.Remove filter box service access cover, allowing cooler air to move hot air through the furnace, cooling the plenum and the house hot air duct system.

If power fails, to avoid product damage, close manual draft completely. Forced draft and natural draft are pre- set.

In the event of a runaway fire, close all drafts. Close smoke damper halfway.

8

Image 8
Contents INSTRUCTION AND PARTS BOOK FOR MODELSPhone 715/654-5132 Fax 715/654-5513 07/97INTRODUCTION TRANSPORTATION DAMAGESTABLE OF CONTENTS FURNACE SAFETY DANGERDANGER DANGERSPECIFICATIONS MODELDISCLAIMER NOTICE MODELGENERAL INFORMATION HIGH QUALITY CONSTRUCTIONEFFICIENCY COMFORTADDITION COMFORT AND SAVING FIGURE FIGUREOPERATION PROCEDURE IN THE EVENT OF POWER FAILURE OPERATIONCOMMON SENSE IF YOU HAVE CHIMNEY FIREOPERATING YOUR WOODCHUCK FURNACE BURNING WOOD IN YOUR WOOD- CHUCKSTARTUP FIGURE 5 WOODCHUCK CONTROLSASH REMOVAL HELPFUL HINTSBURNING COAL IN YOUR WOOD- CHUCK STARTING A COAL FIRERECHARGING BANKINGASH REMOVAL MAINTENANCEOPTIONAL CATALYTIC COMBUSTOR FOR MODELS 2900/4000 TROUBLE SHOOTING PROBLEMSOLUTION POSSIBLE CAUSEPROBLEM SOLUTIONPOSSIBLE CAUSE 9. Excessive amounts ofINSTALLATION PLACEMENT AND MINIMUM CLEAR ANCESGENERAL REQUIREMENTS FIGURE 7 LOCATING THE WOODCHUCKFIGURE 8 TYPICAL CHIMNEY CHECKLIST FIGURE 9 CHIMNEY/ROOF CLEARANCE CHIMNEY INSTALLATIONTYPICAL STOVE PIPE INSTALLATION INSTALLING YOUR WOODCHUCK STOVE PIPE INSTALLATIONINSTALLATION OF A BAROMETRIC DRAFT DAMPERS IN STOVE PIPESAIR DUCT INSTALLATION ADD-ONINSTALLATIONSWOODCHUCK FINAL ASSEMBLY OPTIONAL SHAKER GRATE INSTALLATION FOR MODELFIGURE 12 PARALLEL ADD-ONINSTALLATION FIGURE 13 CENTRAL ADD-ONINSTALLATIONFIGURE 15 INSTALL SHAKER GRATE HANDLE INSTALL SHAKER GRATE HANDLE MODEL 2900 ONLYFIGURE 14 POOR INSTALLATIONS FIGURE 17 INSTALL FIREBRICK INSTALL FIREBRICKFIGURE 16 INSTALL OPTIONAL SHAKER GRATE FOR MODEL FIGURE 19 INSTALL MANUAL DRAFT-MODEL526 ASSEMBLE MANUAL DRAFT MODEL 526 ONLYINSTALL CIRCULATING BLOWER INSTALL FILTER BOXFEED MOTORFIGURE 21 INSTALL CIRCULATING BLOWER AND FILTER ELECTRICAL HOOKUP FIGUREFIGURE 22 ELECTRICAL WIRING DIAGRAM REPAIR PARTS BASIC UNIT FOR MODELKEY NO. PART NO DESCRIPTIONBASIC UNIT FOR MODEL KEY NO. PART NODESCRIPTION KEY NO. PART NOBASIC UNIT FOR MODEL KEY NO. PART NODESCRIPTION KEY NO. PART NO#05-5260-OPTIONALSHAKER GRATE FOR MODEL #05-2900SHAKER GRATE FOR MODELS 2900/4000FILTER BOX 2900/4000CIRCULATING BLOWER #08-0100 COMFORT CONTROL #08-0090COMPLETE BLOWER ASSYDESCRIPTION KEY NO. PART NO. DESCRIPTION46-2900-8Wiring Diagram PERSONAL DATA INFORMATION FOR FUTURE REFERENCE This Page Intentionally Blank LIMITED WARRANTY Manufactured By MEYER MANUFACTURING CORPORATION P.O. BoxDorchester, Wisconsin Dorchester, Wisconsin