Louisville Tin and Stove W351F, W506 Contents, Readcarefullybefore Installingunit, Introduction

Page 2

 

 

CONTENTS

 

Introduction

2

Rear Register Kit Instructions

9

Specifications

2

Lighting Instructions

10/11

Safety Rules

3

Pilot Adjustment

12

Clearances

3

Burner Flame Adjustment

12

Controls

3

Maintenance Instructions

12

Combustion & Ventilation Air

4

WFF81 Fan Instructions

13/14

Venting

5,6

Trouble Shooting Chart

15/16

Rough-In Instructions

6

Parts Drawing

17

Installation

8

Parts List

18

Wiring Instructions

9

Warranty

20

READCAREFULLYBEFORE INSTALLINGUNIT

These installation instructions are a general guide, and do not supersede applicable local codes and ordinances. Before planning or making the installation, be sure it complies with all phases of the local heating codes. Or, in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI.Z223.1. In Canada, see the current installation code CAN1-B149.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the latest edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, see the current Canadian Electrical Code C5AC22.1.

The ANSI standards are available from the American Gas Association, 1515 Wilson Blvd., Arlington, Virginia 22209.

The NFPA standards are available from the National Fire Protection Association, Batterymarch Park, Quincy, MA. 02269.

Canadian standards are available from International Approval Services,178 Rexdale Blvd.,Etobicoke,Ontario, Canada M9W 1R3.

NOTE: If optional rear register kit is to be used, see supplemental installation instructions (No. 84504) and section marked “Special Instructions for Rear Register Kit Application” prior to installation of Rough-In.

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS, CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.

SPECIFICATIONS

Your vented wall furnace comes packed in a single carton. (For wall thermostat models that includes the thermostat, thermostat wire, and insulated staples). Before installing the wall furnace check the rating plate to verify that the Model Number is correct and that the wall furnace is equipped for the type gas you intend to use.

Model

Type

Type

BTU/Hr.

Vent

Gas

 

Shpg.

REAR REG. KIT

FAN KIT

No.

Control

Gas

Input

Size

Inlet

FINISHED DIMENSIONS

Wt.

 

Model

Weight

Model

Wt.

 

 

 

 

 

 

SINGLE WALL FURNACE

 

 

 

 

 

 

 

W251F

Snap Bulb

Nat.

25,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W255F

Wall Stat

Nat.

25,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W252F

Snap Bulb

L . P.

25,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W256F

Wall Stat

L . P.

25,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W351F

Snap Bulb

Nat.

35,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W355F

Wall Stat

Nat.

35,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W352F

Snap Bulb

L . P.

35,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

W356F

Wall Stat

L . P.

35,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

90

Lbs.

40542

5 Lbs.

WFF81

10 lbs.

 

 

 

 

 

 

DUAL WALL FURNACE

 

 

 

 

 

 

 

W501F

Snap Bulb

Nat.

50,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

134

Lbs.

N/A

N/A

WFF81

10 lbs.

W505F

Wall Stat

Nat.

50,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

134

Lbs.

N/A

N/A

WFF81

10 lbs.

W502F

Snap Bulb

L . P.

50,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

134

Lbs.

N/A

N/A

WFF81

10 lbs.

W506F

Wall Stat

L . P.

50,000

4”

1/2”

16-1/2”Wx68”Hx6-1/2”D

134

Lbs.

N/A

N/A

WFF81

10 lbs.

One or two fan kits may be used on dual-wall furnace.

Page 2

Image 2
Contents GAS This Unit is not to be Installed in Mobile HomesNatural What to do if YOU Smell GASSpecifications ContentsReadcarefullybefore Installingunit IntroductionSafety Rules Natural GASCombustion and Ventilation AIR ALL Combustion AIR from Outdoors Through Ventilated AtticVenting Square Hole BTU Size =Figure a ROUGH-IN Dimensions ROUGH-IN InstructionsInstallation Vent Burner ShelfWall Wiring Instructions Gravity Wall FurnaceNAT ThermostatWhat to do if YOU Smell GAS PilotModel W251F, W252F / W351F, W352F / W501F, W502F Pilot Adjustment Pilot Flame AdjustmentBurner Flame Adjustment Stainless Steel Burner Maintenance InstructionsModel WFF81-COPTIONAL FAN KIT StepWhite Black White Motor Green Ground Wire Black FAN SwitchTrouble Shooting Chart for qualified serviceman Main Burner Symptom Possible Causes Corrective ActionPossible Causes Corrective Action Trouble Shooting Chart Automatic Pilot & ValveDo not Bypass the Blocked Flue Switch Gravity Wall Furnace List Prices - June Burner Assembly / Single Wall FurnaceBurner Assembly Single Wall FurnaceTWO Required August Part Description PriceIf YOU CAN’T Light IT Your GAS Control and Pilot Light SystemTampering is Dangerous DON’T Fight ITLimited Warranty Table a