PLANNING YOUR INSTALLATION

QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood pellet burning appliances are improperly installed. The installer must follow all of the manufac- turers’ instructions.

The installation of this appliance must conform to local codes and applicable state and federal requirements. Familiarity with these requirements before installation is essential. Important considerations to discuss with local building officials include:

1.Applicable codes (i.e. Uniform Mechanical Code, State or Regional Codes).

Electrical codes:

In USA, NEC, ANSI / NFPA 70 – Latest Edition In Canada, CSA C22.1 – Latest Edition

Power Supply Requirements – The power cord must be plugged into a standard, 115 volt, 60 Hz grounded electrical outlet. The approximate power requirement is 362 Watts, and will peak up to 736 Watts for approxi- mately 6 minutes when the self-igniter is operating (it will turn off 2 minutes after flame detection). The power cord must be routed to avoid contact with any of the hot or sharp exterior surface areas of the stove. When in- stalled into a manufactured (mobile) home, the appli- ance must be electrically grounded to the steel chassis (see page 8, Manufactured [Mobile] Home Require- ments). These requirements must be met unless other- wise specified by state or local authorities.

WARNING - ELECTRICAL GROUNDING IN- STRUCTIONS: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DI- RECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.

2.Local amendments?

3.Is a permit required - cost?

You may wish to contact your insurance company to ask if they require this.

4.Is outside combustion air required?

5.Rooms where the installation is not allowed?

INSTALLATION / MAINTENANCE STANDARDS

National Fire Protection Association – The primary NFPA standard that refers to installation and mainte- nance of pellet appliances and venting is NFPA 211 – Latest Edition: Chimneys, Fireplaces, Vents, and Solid Fuel appliances.

SELECTING A LOCATION

The design of your home and where you place your stove will determine its value as a source of heat. A pel- let stove depends primarily on air circulation (convec- tion) to disperse its heat, and therefore, a central loca- tion is often best. There are other practical considera- tions, which must be considered before a final selection of locations is made.

Existing Chimneys

Pellet Fuel Storage

Aesthetic Considerations

Roof Design (rafter locations & roof pitch)

Room Traffic

Proximity to Combustibles

Electrical Wiring

The installation of this stove will require some research. Once your options are determined, consult with your local building department who will be able to give you the necessary installation requirements for your area (Is a building permit required? Rooms where installation may not be allowed, etc.).

WARNING: CHECK ALL LOCAL BUILDING AND SAFETY CODES BEFORE INSTALLATION. THE IN- STALLATION INSTRUCTIONS AND APPROPRIATE CODE REQUIREMENTS MUST BE FOLLOWED EX- ACTLY AND WITHOUT COMPROMISE. ALTERA- TIONS TO THE STOVE ARE NOT ALLOWED. DO NOT CONNECT THE STOVE TO A CHIMNEY SYS- TEM SERVING ANOTHER STOVE, APPLIANCE, OR ANY AIR DISTRIBUTION DUCT. FAILURE TO FOL- LOW THESE INSTRUCTIONS WILL VOID THE MANUFACTURERS WARRANTY.

SMOKE DETECTORS

Since there are always several potential sources of fire in any home, we recommend installing smoke detec- tors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occa- sional false activation from the heat produced by the stove). If your local code requires a smoke detector be installed within the same room, you must follow the re- quirements of your local code. Check with your local building department for requirements in your area.

PAGE 4

www.PelletKing.com

Image 4
Contents Installation and Operation Manual Freestanding Insert Pellet Fired StovesImportant Warnings Table of Contents Planning Your Installation Installation / Maintenance StandardsSelecting a Location Smoke DetectorsListed Material Floor Protection Advantage II-T C FSApproved Alternate Materials for Floor/Hearth Protection Minimum Clearances to Combustibles ClearancesAdvantage II-T C Masonry and Factory Built Fireplaces Manufactured Mobile Home INSTAL- Lation Model Advantage II-T C FS Pedestal Air InletInstallation ASH PAN Cover AssemblyInstalling Pedestal to Body Removing Appliance from PalletInstallation Check List Check listPrior to lighting your stove After you have begun operation of your stoveTop Surround Panel Thermostat Installation Rear View of Advantage II-T C FSVenting Requirements Vent Termination Manufactured Mobile Home Chimney Height RequirementsDetermining Size of Pipe to Install Installation ChartSample Installation Chart Pipe Selection ChartPipe Top View Illustration Advantage II-T C FS Corner Through the WallHorizontal Vent Through the Wall Vertical Vent Into a Masonry Flue Existing Class a ChimneyVent Termination When Liner is Used Installation Advantage II-T C INSUSA & Canada Direct Connection / Posi- tive Flue Connection Installing Advantage II-T C INS Important NotesControl Board Operation Care and OperationControl Board PRE-LIGHTING Instructions Starting Your Pellet StoveGeneral Operating Considerations Turning OFF Your Pellet StoveDamper Operation Damper In less airDamper Adjustment Guideline Automatic Safety FeaturesPower Outage OverheatingFuel UltraGrateTMRoutine Maintenance Routine CleaningProper Disposal of Ashes UltraGrateTM ASH PAN Advantage II-T C FSASH Trap and Baffles Heat Exchanger TubesMinimum Frequency of 3 months to 1 year Door Rope GasketCreosote Removal Window Wash Remove Window Wash BracketOpening Side Panels Advantage II-T C FS Opening Side PanelsSmall Area Paint TOUCH-UP Motor LubricationSide View Illustration Specifications Advantage II-T C FSBack View Illustration Front View Side ViewComponent Definitions Wiring Diagram Troubleshooting Qualified Technicians Only Damper Adjustment Guidelines Troubleshooting Qualified Technicians Only Replacement Parts List Freestanding Only Parts Insert Only PartsMiscellaneous Parts Firebox PartsFirebrick Kit Replacement Part DiagramsPiece Set UltraGrate TM Kit Pressure Switch Kit Optional Accessories List and Diagrams Catalog # Model Description Stove ModelGold Trivet Cat. # H0423 Surround Kits & Trim Kits Log Set Cat. #H0430Advantage II-T C Pellet Stove Safety Label Advantage II-T C EPA Label & Colorado Compliance Label Simple Operating Instructions Label Installation Tips Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA

II-T C FS, II-T C INS specifications

The Lennox Hearth II-T C INS and II-T C FS are exemplary models in the world of modern heating solutions, designed for efficiency, comfort, and style. With innovative engineering and advanced technology, these units cater to the needs of contemporary homeowners seeking reliable and aesthetically pleasing heating options.

One of the main features of the Lennox Hearth II-T C INS and II-T C FS is their exceptional efficiency ratings. These models are designed to operate at high efficiency levels, reducing energy consumption while providing optimal warmth. This not only translates to lower utility bills but also represents a more sustainable choice for environmentally conscious consumers.

A standout characteristic of these products is their versatility in installation. The II-T C INS is an insert model, allowing it to be fitted into existing fireplaces easily. This makes it an ideal option for homeowners wanting to upgrade their current heating systems without extensive renovations. The II-T C FS, on the other hand, is a freestanding stove that adds a classic touch to any room, making it a perfect focal point while offering powerful heating capabilities.

Both models are equipped with advanced technology designed for seamless operation. The hot air circulation system ensures that warmth is evenly distributed throughout the space, eliminating cold spots and enhancing overall comfort. In addition, their adjustable thermostats allow users to set the desired temperature with ease, ensuring a consistent indoor environment.

The Lennox Hearth units are also designed with user convenience in mind. They come with easy-to-use controls and can often be integrated with smart home systems, offering the flexibility to monitor and adjust settings remotely. This modern approach to home heating makes it simple for users to maintain a cozy atmosphere, even on the coldest days.

Moreover, Lennox places a strong emphasis on safety. These heating models include features such as a glass door that remains cool to the touch and a built-in safety shut-off system, providing peace of mind for families.

In summary, the Lennox Hearth II-T C INS and II-T C FS models stand out for their efficiency, versatility, advanced technology, and safety features. With a focus on optimal performance and user convenience, these units represent a significant advancement in home heating, making them an attractive choice for those looking to enhance their living spaces while staying warm and comfortable.