Lennox Hearth II-T C INS, II-T C FS operation manual Manufactured Mobile Home INSTAL- Lation

Page 8

PLANNING YOUR INSTALLATION

MANUFACTURED (MOBILE) HOME INSTAL- LATION

Freestanding Model – Advantage II-T C FS

In addition to the standard installation instructions, the following instructions may be required by lo- cal, state or federal building codes:

Stove must be permanently bolted to the floor.

An outside air inlet must be provided for com- bustion and be unrestricted while unit is in use. Use a galvanized or stainless steel pipe for the duct (the outside air inlet on the stove is 1 5/8" diameter).

Stove must be permanently electrically grounded to the steel chassis of the home. The location selected for ground attachment to the stove must be dedicated for this purpose.

See pages 13 through 18 for additional informa- tion on venting requirements.

Do not install appliance in a sleeping room.

The structural integrity of the manufactured home floor, walls, ceiling and roof must be maintained.

NOTE:The grounding of this product, at installa- tion, must comply with NFPA-70 stan- dards, CSA C22.1 in Canada, as well as any local codes.

Model – Advantage II-T C FS

Pedestal Air Inlet

25”

6 7/8”

12 ½”

24 ¾”

Outside Air Inlet 1 5/8" diameter

MANUFACTURED (MOBILE) HOME EXHAUST VENT PIPE INSTALLATION GUIDELINES

Use only “PL” pellet vent pipe listed to UL 641 and ULC S609. The pipe should extend at least 3 feet above the part of the roof through which it passes. The top of the pipe should be at least 2 feet above the highest required elevation of any part of the manufactured (mobile) home within 10 feet of the pipe (see page 14, Manufactured [Mobile] Home Chimney Height Requirements).

If the exhaust vent exits the manufactured (mobile) home at a location other than the roof, and exits at a point 7 feet or less above the ground level on which the manufactured (mobile) home is position a guard or method of enclosing the pipe shall be provided at the point of exit for a height of up to 7 feet. The openings, if any, in this guard shall not allow a 3/4” rod to pass through. A 1/2” rod could pass through but should not be able to touch the pipe when inserted through the open- ing a distance of 4 inches.

 

Bolt

Bolt

Floor Protector

 

Floor

 

Steel Chassis

 

Ground

 

To Chassis

PAGE 8

www.PelletKing.com

Image 8
Contents Installation and Operation Manual Freestanding Insert Pellet Fired StovesImportant Warnings Table of Contents Planning Your Installation Installation / Maintenance StandardsSelecting a Location Smoke DetectorsApproved Alternate Materials for Floor/Hearth Protection Floor Protection Advantage II-T C FSListed Material Advantage II-T C ClearancesMinimum Clearances to Combustibles Masonry and Factory Built Fireplaces Manufactured Mobile Home INSTAL- Lation Model Advantage II-T C FS Pedestal Air InletInstallation ASH PAN Cover AssemblyInstalling Pedestal to Body Removing Appliance from PalletInstallation Check List Check listPrior to lighting your stove After you have begun operation of your stoveTop Surround Panel Thermostat Installation Rear View of Advantage II-T C FSVenting Requirements Vent Termination Manufactured Mobile Home Chimney Height RequirementsDetermining Size of Pipe to Install Installation ChartSample Installation Chart Pipe Selection ChartPipe Horizontal Vent Through the Wall Advantage II-T C FS Corner Through the WallTop View Illustration Vertical Vent Into a Masonry Flue Existing Class a ChimneyUSA & Canada Direct Connection / Posi- tive Flue Connection Installation Advantage II-T C INSVent Termination When Liner is Used Installing Advantage II-T C INS Important NotesControl Board Care and OperationControl Board Operation PRE-LIGHTING Instructions Starting Your Pellet StoveGeneral Operating Considerations Turning OFF Your Pellet StoveDamper Operation Damper In less airDamper Adjustment Guideline Automatic Safety FeaturesPower Outage OverheatingFuel UltraGrateTMRoutine Maintenance Routine CleaningProper Disposal of Ashes UltraGrateTM ASH PAN Advantage II-T C FSASH Trap and Baffles Heat Exchanger TubesCreosote Removal Door Rope GasketMinimum Frequency of 3 months to 1 year Window Wash Remove Window Wash BracketOpening Side Panels Advantage II-T C FS Opening Side PanelsSmall Area Paint TOUCH-UP Motor LubricationBack View Illustration Specifications Advantage II-T C FSSide View Illustration Front View Side ViewComponent Definitions Wiring Diagram Troubleshooting Qualified Technicians Only Damper Adjustment Guidelines Troubleshooting Qualified Technicians Only Replacement Parts List Freestanding Only Parts Insert Only PartsMiscellaneous Parts Firebox PartsPiece Set UltraGrate TM Kit Replacement Part DiagramsFirebrick Kit Pressure Switch Kit Optional Accessories List and Diagrams Catalog # Model Description Stove ModelGold Trivet Cat. # H0423 Surround Kits & Trim Kits Log Set Cat. #H0430Advantage II-T C Pellet Stove Safety Label Advantage II-T C EPA Label & Colorado Compliance Label Simple Operating Instructions Label Installation Tips Service and Maintenance LOG Ownership RecordsWest Taft Avenue Orange, CA

II-T C FS, II-T C INS specifications

The Lennox Hearth II-T C INS and II-T C FS are exemplary models in the world of modern heating solutions, designed for efficiency, comfort, and style. With innovative engineering and advanced technology, these units cater to the needs of contemporary homeowners seeking reliable and aesthetically pleasing heating options.

One of the main features of the Lennox Hearth II-T C INS and II-T C FS is their exceptional efficiency ratings. These models are designed to operate at high efficiency levels, reducing energy consumption while providing optimal warmth. This not only translates to lower utility bills but also represents a more sustainable choice for environmentally conscious consumers.

A standout characteristic of these products is their versatility in installation. The II-T C INS is an insert model, allowing it to be fitted into existing fireplaces easily. This makes it an ideal option for homeowners wanting to upgrade their current heating systems without extensive renovations. The II-T C FS, on the other hand, is a freestanding stove that adds a classic touch to any room, making it a perfect focal point while offering powerful heating capabilities.

Both models are equipped with advanced technology designed for seamless operation. The hot air circulation system ensures that warmth is evenly distributed throughout the space, eliminating cold spots and enhancing overall comfort. In addition, their adjustable thermostats allow users to set the desired temperature with ease, ensuring a consistent indoor environment.

The Lennox Hearth units are also designed with user convenience in mind. They come with easy-to-use controls and can often be integrated with smart home systems, offering the flexibility to monitor and adjust settings remotely. This modern approach to home heating makes it simple for users to maintain a cozy atmosphere, even on the coldest days.

Moreover, Lennox places a strong emphasis on safety. These heating models include features such as a glass door that remains cool to the touch and a built-in safety shut-off system, providing peace of mind for families.

In summary, the Lennox Hearth II-T C INS and II-T C FS models stand out for their efficiency, versatility, advanced technology, and safety features. With a focus on optimal performance and user convenience, these units represent a significant advancement in home heating, making them an attractive choice for those looking to enhance their living spaces while staying warm and comfortable.