Selection
Procedure
Table
2 Lbs. Steam 60 F Entering AirTemp
| Motor | Motor | BTU |
| Condensate | Final | CFM 70 F | Outlet | Oper. | |
Size | HP | RPM | Per Hour | EDR | Lbs Per Hr | Temp | Air Basis | Velocity | Weight | |
|
|
|
|
| Standard Units |
|
|
|
|
|
|
| 1050 | 17,400 | 72 | 18 | 117 | 280 | 162 |
|
|
1/50 | 950 | 16,600 | 69 | 17 | 118 | 266 | 154 | 40 | ||
|
| 800 | 13,900 | 58 | 14 | 118 | 224 | 130 |
|
|
|
| 1050 | 20,000 | 84 | 21 | 118 | 318 | 186 |
|
|
1/50 | 950 | 19,000 | 79 | 20 | 120 | 298 | 173 | 40 | ||
|
| 800 | 15,500 | 64 | 17 | 120 | 250 | 145 |
|
|
|
| 1550 | 38,700 | 162 | 40 | 126 | 544 | 319 |
|
|
1/20 | 1300 | 35,900 | 150 | 37 | 130 | 472 | 279 | 40 | ||
|
| 1100 | 32,700 | 136 | 33 | 135 | 399 | 238 |
|
|
|
| 1550 | 41,600 | 174 | 43 | 125 | 590 | 347 |
|
|
1/20 | 1300 | 38,000 | 158 | 39 | 130 | 495 | 294 | 40 | ||
|
| 1100 | 34,700 | 145 | 35 | 136 | 420 | 251 |
|
|
|
| 1550 | 60,500 | 252 | 64 | 129 | 815 | 343 |
|
|
1/20 | 1300 | 56,000 | 234 | 58 | 133 | 706 | 300 | 55 | ||
|
| 1100 | 51,200 | 214 | 52 | 139 | 597 | 256 |
|
|
|
| 1550 | 68,200 | 285 | 70 | 117 | 1100 | 454 |
|
|
1/8 | 1300 | 64,900 | 271 | 67 | 123 | 953 | 397 | 60 | ||
|
| 1100 | 59,700 | 248 | 61 | 128 | 806 | 339 |
|
|
|
| 1550 | 87,600 | 366 | 90 | 127 | 1214 | 382 |
|
|
1/8 | 1300 | 81,200 | 340 | 84 | 131 | 1053 | 334 | 75 | ||
|
| 1100 | 74,200 | 310 | 76 | 137 | 891 | 285 |
|
|
|
| 1550 | 96,000 | 400 | 99 | 118 | 1535 | 476 |
|
|
1/8 | 1300 | 91,500 | 380 | 94 | 123 | 1330 | 417 | 85 | ||
|
| 1100 | 84,000 | 350 | 86 | 128 | 1126 | 356 |
|
|
1/6 | 1100 | 125,700 | 525 | 130 | 126 | 1760 | 411 | 100 | ||
1/6 | 1100 | 172,000 | 716 | 178 | 127 | 2380 | 452 | 145 | ||
1/4 | 1100 | 185,200 | 775 | 191 | 121 | 2808 | 528 | 145 | ||
1/4 | 1100 | 229,700 | 957 | 237 | 124 | 3300 | 431 | 190 | ||
1/2 | 1100 | 256,300 | 1070 | 265 | 118 | 4100 | 529 | 195 | ||
1/2 | 1100 | 324,000 | 1350 | 335 | 127 | 4480 | 442 | 245 | ||
1/2 | 1100 | 355,500 | 1480 | 368 | 118 | 5660 | 550 | 250 | ||
3/4 | 1145 | 404,073 | 1684 | 418 | 122 | 6017 | 583 | 260 |
Notes:
1.Constant speed units are rated at capacities shown in regular type: Capacities in italic faced type apply only to units with
2.Capacities based on 2 psi steam and 60 F entering air.
15 |