Trane UH-PRC001-EN manual Dimensions and Weights, Figure DW-2

Page 48
Figure DW-2

Dimensions

and Weights

Table DW-2 - Model P Unit Heater Roughing In Dimensions (Figure DW-2)*

Unit

Fan

 

 

 

 

 

 

 

 

 

L

P

 

 

 

 

 

Size

Dia.

A

B

C

D

E

F

G

H

K

(Min.)

(NPT)

R

S

T

U

V

102

163/4

251/4

61/8

2

171/2

11/8

3

17

13/8

23/4

7

11/2

41/8

91/8

23/4

17

41/8

122

163/4

251/4

61/8

2

171/2

13/4

3

17

13/8

23/4

7

11/2

41/8

93/4

23/4

17

41/8

146

193/4

291/2

61/8

23/8

205/8

11/4

4

201/2

13/4

31/2

7

2

41/2

95/8

23/4

201/2

41/2

166

193/4

291/2

61/8

23/8

205/8

13/4

4

201/2

13/4

31/2

7

2

41/2

101/8

23/4

201/2

41/2

202

193/4

291/2

75/8

23/8

205/8

2

4

201/2

13/4

31/2

7

2

41/2

12

23/4

201/2

41/2

252

251/4

371/2

75/8

3

263/8

1

31/2

28

13/4

31/2

7

2

43/4

115/8

23/4

18

93/4

280

251/4

371/2

75/8

3

263/8

11/4

31/2

28

13/4

31/2

7

2

43/4

113/4

23/4

18

93/4

336

251/4

371/2

75/8

3

263/8

21/8

4

28

13/4

31/2

7

2

43/4

123/4

23/4

18

93/4

384

251/4

371/2

91/8

3

263/8

2

31/2

28

13/4

31/2

7

2

43/4

141/8

23/4

18

93/4

500

30

42

91/8

31/2

311/4

15/8

3

30

21/4

41/4

7

21/2

6

141/4

3

30

6

600

30

42

121/8

31/2

311/4

21/8

3

30

21/4

41/4

7

21/2

6

173/4

3

30

6

720

30

42

135/8

31/2

311/4

3

4

30

21/4

41/4

7

21/2

6

201/4

3

30

6

Figure DW-2

48

UH-PRC001-EN

Image 48
Contents UH-PRC001-EN Propeller Unit Heaters/Unitary17.4 to 705.6 MBh OctoberIntroduction The Industrial Designed Model P Unit HeaterContents Features and BenefitsSelection Procedure Electric PowerFeatures and Benefits Put HeatWhere It’s NeededThe Model S Coil The Model P MotorCompact Design Rectangular Draw-ThruCoilsModel P Model SFeatures and Benefits External Couplings Features and BenefitsApplication Considerations General RulesTypical Factory HotWater System - Using Circulating Pump General NotesApplication Considerations Vapor orVacuum System HotWater System with Circulating PumpApplication Considerations Figure AC-4 Figure AC-5 Figure AC-6Selection Procedure Trane Propeller Unit HeatersBTU Requirements Type of BuildingFormula Determining Special Steam CapacitiesUseful Data Equivalent Direct RadiationModel S Nomenclature D BESelection Procedure Model S Model PSelection Procedure Table Based on 2 PSIG and 60 F Entering AirSelection Procedure 2 Lbs. Steam 60 F Entering AirTempSelection Procedure 2 Lbs. Steam 60 F Entering AirTempSelection Procedure Table SP-6- Maximum Spread FtAdditional Selection Data Model P NomenclatureMotor and Fan Speeds Selection ProcedureSelection Procedure HotWater Selection ExampleSelection Procedure StepCorrection Factors for Propylene Glycol/Water Propylene GlycolPropylene GlycolModel Number Description MODEL P UNIT HEATERMotors D B E Model Number DescriptionMotors Performance Data Performance Data WaterPerformance Data WaterPerformance Data WaterPerformance Data Entering WaterTemperaturePerformance Data Entering WaterTemperaturePerformance Data 117.6Performance Data Entering WaterTemperaturePerformance Data Entering WaterTemperaturePerformance Data WaterPerformance Data WaterPerformance Data WaterPerformance Data 115.1Performance Data WaterPerformance Data WaterPerformance Data Entering WaterTemperaturePerformance Data Entering WaterTemperaturePerformance Data Entering WaterTemperaturePerformance Data 100.1Performance Data Entering WaterTemperaturePerformance Data Entering WaterTemperatureElectric Power Electric Power AccessoryElectric Power ModelDimensions and Weights Figure DW-1Motor MountType-1 Motor MountType-2Dimensions and Weights Figure DW-2Dimensions and Weights In Dimensions Figure DW-4Figure DW-3 Table DW-4- Louver Cone Diffuser RoughingMechanical Specifications Model P GeneralCasing Model S GeneralPage NRTL/C TheTrane Company