Trane UH-PRC001-EN manual Model Number Description, Model P Unit Heater, Motors

Page 21
Model

Model

Number

Description

 

 

 

 

 

 

 

 

 

MODEL P UNIT HEATER

 

UHP

A

0 4 2

P

4

C

A

A

1

T

 

A

R

C

A

D

B

E

123

4

5 6 7

8

9

10

11

12

13

14

 

15

16

17

18

19

20

21

Digits 1,2,3 — ProductType

 

 

 

 

Digit 13 —Voltage

 

 

 

UHP

 

 

 

 

 

 

 

 

1

= 115/60/1*

 

 

 

 

 

 

 

 

 

 

 

 

 

2

=

208/60/3

 

 

 

 

 

Digit 4 — Development Sequence

 

 

 

3

=

230/60/3

 

 

 

 

 

A

 

 

 

 

 

 

 

 

4

=

460/60/3

 

 

 

 

 

 

 

 

 

 

 

 

 

5

=

575/60/3 (Totally Enclosed)

 

 

 

 

 

 

 

 

 

Digits 5,6,7 — Unit Size

 

 

 

 

 

Digit 14 — MotorType

 

 

 

042

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T =Totally Enclosed*

 

 

 

064

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E = Explosion Proof

 

 

 

080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

102

 

 

 

 

 

 

 

 

Digit 15 — Fan Guard

 

 

 

122

 

 

 

 

 

 

 

 

 

 

 

146

 

 

 

 

 

 

 

 

0

= Standard*

 

 

 

 

166

 

 

 

 

 

 

 

 

A = OSHA Guard**

 

 

 

202

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

252

Digit 16 — Unit Coating

280

0 = None

336

R = Epoxy

384

T = Epoxy Phenollic

500

W = Baked Phenolic

600

 

720

Digit 17 — Diffuser

 

Motors

Standard motors are 115/60/1, totally enclosed, with thermal overload protection for all units through size 280P. Standard motors for 42P, 64P and 80P are standard pole, sleeve bearing.The 102P motor is permanent split capacitor type with sleeve bearings. Motor for unit sizes 122P through 280P are permanent split capacitor type with permanently lubricated ball bearings. Motors used on unit sizes 336P through 720P are 230/460/ 60/3, totally enclosed, with permanently lubricated ball bearings. Unit sizes smaller than 336P are also available with 230/460/60/3 motors.

All motors, fractional hp and integral hp, have Class “B” insulation.The 115/60/1 motors used as standard on unit sizes 42P through 102P can be operated at multiple speeds with the addition of a

Digit 8 — CoilType

P = Steam or Hot Water*

Digit 9 — Fin Series

4 = 144*

Digit 10 — Design Sequence

C

Digit 11 —Tube Material

A = Copper*

C = Red Brass

F = Steel

Digit 12 — Fin Material

A= Aluminum* C = Copper

0 = None

A = Fin Diffuser

C = Fin Diffuser w/coating

Digit 18 — Manual Starter

0 = None

A = Manual Starter w/o overload protection

Digit 19 — Speed Controller (115/60/1 standard motors)

0 = None

D= Solid-State Speed Controller (only available up to unit size 102)

Digit 20 —Thermostats

0 = None

B = Light-DutyT-stat

C = Heavy-DutyT-stat

Digit 21 — Subbase

0 = None

E = Light-Duty

F = Heavy-Duty

solid-state control.

All units available with explosion-proof motors.

* Standard features of stock vertical heaters.

**For the 3-phase and explosion-proof motors, the OSHA guard ships separately.

UH-PRC001-EN

21

Image 21
Contents Propeller Unit Heaters/Unitary UH-PRC001-EN17.4 to 705.6 MBh OctoberThe Industrial Designed Model P Unit Heater IntroductionFeatures and Benefits ContentsSelection Procedure Electric PowerPut HeatWhere It’s Needed Features and BenefitsThe Model P Motor The Model S CoilCompact Design Rectangular Draw-ThruCoilsModel P Model SFeatures and Benefits Features and Benefits External CouplingsApplication Considerations General RulesTypical Factory HotWater System - Using Circulating Pump General NotesApplication Considerations HotWater System with Circulating Pump Vapor orVacuum SystemApplication Considerations Figure AC-4 Figure AC-5 Figure AC-6Trane Propeller Unit Heaters Selection ProcedureBTU Requirements Type of BuildingDetermining Special Steam Capacities FormulaUseful Data Equivalent Direct RadiationModel S Nomenclature D BESelection Procedure Model P Model SSelection Procedure Table Based on 2 PSIG and 60 F Entering Air2 Lbs. Steam 60 F Entering AirTemp Selection Procedure2 Lbs. Steam 60 F Entering AirTemp Selection ProcedureTable SP-6- Maximum Spread Ft Selection ProcedureModel P Nomenclature Additional Selection DataMotor and Fan Speeds Selection ProcedureHotWater Selection Example Selection ProcedureSelection Procedure StepPropylene Glycol Correction Factors for Propylene Glycol/WaterPropylene GlycolModel Number Description MODEL P UNIT HEATERMotors D B E Model Number DescriptionMotors Performance Data Water Performance DataWater Performance DataWater Performance DataEntering WaterTemperature Performance DataEntering WaterTemperature Performance Data117.6 Performance DataEntering WaterTemperature Performance DataEntering WaterTemperature Performance DataWater Performance DataWater Performance DataWater Performance Data115.1 Performance DataWater Performance DataWater Performance DataEntering WaterTemperature Performance DataEntering WaterTemperature Performance DataEntering WaterTemperature Performance Data100.1 Performance DataEntering WaterTemperature Performance DataEntering WaterTemperature Performance DataElectric Power Accessory Electric PowerModel Electric PowerFigure DW-1 Dimensions and WeightsMotor MountType-1 Motor MountType-2Figure DW-2 Dimensions and WeightsIn Dimensions Figure DW-4 Dimensions and WeightsFigure DW-3 Table DW-4- Louver Cone Diffuser RoughingModel P General Mechanical SpecificationsCasing Model S GeneralPage TheTrane Company NRTL/C