State Industries Commercial Gas Water Heater instruction manual Periodic Maintenance cont’d

Page 28

Periodic Maintenance (cont’d)

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

WARNING

INSTALLED IN SUITABLE AREA: To insure sufficient venti- lation and combustion air supply, proper clearances from the water heater must be maintained. See “Locating the New Water Heater” section. Combustible materials such as cloth- ing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater which can cause a fire.

Oiling Instructions

Oil Fasco motor only every 12 months with 6 drops of SAE 20 motor oil.

Temperature-Pressure Relief Valve Operation

The temperature-pressure relief valve must be manually operated at least once a year.

TEMPERATURE-PRESSURE

RELIEF VALVE

Draining

The water heater should be drained if being shut down dur- ing freezing temperatures. Also periodic draining and clean- ing of sediment from the tank may be necessary.

1.Turn the gas control knob to the “OFF” position.

2.CLOSE the cold water inlet valve to the water heater.

3.OPEN a nearby hot water faucet and leave open to allow for draining.

4.Connect a hose to the drain valve and terminate to an adequate drain.

5.OPEN the water heater drain valve to allow for tank draining.

NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to ter- minate to an adequate drain.

6.Close the drain valve.

7.Follow instructions in the “Filling The Water Heater” section.

8.Follow the operating instructions in the “Operation” sec- tion to restart the water heater.

Service

If a condition persists or you are uncertain about the oper- ation of the water heater, let a qualified person check it out. Call the local utility and/or plumbing contractor.

DISCHARGE PIPE

WARNING

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water manually discharged will not cause any property damage because the water may be extremely hot.

If after manually operating the valve, it fails to complete- ly reset and continues to release water, immediately close the cold water inlet to the water heater, follow the drain- ing instructions, and replace the temperature-pressure relief valve with a new one.

Failure to install and maintain a new properly listed temperature- pressure relief valve will release the manufacturer from any claim which might result from excessive temperature or pressure.

WARNING

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. Your water heater may have a check valve installed in the water line or a water meter with a check valve. Consult the water supplier and/or plumb- ing contractor for further information. Do not plug the temperature-pressure relief valve.

28

Image 28
Contents For Your Safety AN Odorant is Added to the GAS Used by this Water HeaterWhat to do if YOU Smell GAS Save this Manual for Future ReferenceDischarge Pipe General SafetyMust not be plugged or blocked General Safety cont’d DEATH, Serious Bodily INJURY, or Property DamageTable of Contents Preparing for the New Installation IntroductionTypical Installation Facts to Consider About the Location Locating the New Water HeaterILY INJURY, or Property Damage Locating the New Water Heater cont’d Facts to Consider About the Location cont’dCombustion Air and Exhaust Venting Through an Outside Wall ClearancesWire Fence Air for Ventilation for Appliances Located Confined SpacesVenting Through Roof Clearances 18″Installing the New Water Heater Water PipingInstalling the New Water Heater cont’d Temperature-Pressure Relief ValveOptional Field Installed Wiring WiringFilling the Water Heater Wiring Diagram VentingVenting cont’d Venting Through AN Outside WallInstalling the New Water Heater contd Venting System Example Installations for ALL ModelsVent piping can be installed as follows Minimum vent length for all models is 18 inchesCementing PVC, ABS or Cpvc Pipe and Fittings PrecautionsVent Pipe Separation Connecting Vent to Blower Typical installationVenting contd Venting Through a RoofGas Piping Venting Through a Roof CONT’DGAS Piping with ALL Black Iron Pipe to GAS Control GAS Piping with Flexible ConnectorSediment Trap Installation Checklist Before Operating the Water HeaterIts hookup? Model Rating PlateBefore the Water Heater will Operate OperatingOperation Operating cont’d Check for LeaksFor Your Safety Read Before Operating Temperature Regulation Start Up Conditions For Your InformationOperational Conditions For Your Information cont’d Operational Conditions cont’dPeriodic Maintenance Burner CleaningVenting System Inspection Burner InspectionPeriodic Maintenance cont’d Leakage Checkpoints Troubleshooting Thermostat and GAS Supply CheckTroubleshooting cont’d Diagram for Electrical System Check on pages 32Use diagram on Electrical System CheckFrom facing Installation Diagrams TWO Temp Water Heater InstallationCirculating Tank System GAS/WITH Single Storage System GAS/INSTANTANEOUS or StorageInstallation Diagrams contd Water Heater Installation GAS/INSTANTANEOUSPrimary Plus Booster Water Heater Installation Or StorageRepair Parts ModelThis is a Repair Parts LIST, not a Packing List Repair Parts cont’dPart Description Part Number Page

Commercial Gas Water Heater specifications

State Industries has carved a niche for itself as a leader in the water heating industry, providing reliable solutions for various commercial applications. One of the standout products in their lineup is the State Industries Commercial Gas Water Heater. This powerhouse is designed to meet the demanding hot water needs of businesses, from restaurants and hotels to schools and hospitals.

One of the primary features of the State Commercial Gas Water Heater is its high efficiency. These units are engineered to deliver optimal performance while reducing energy costs. With innovative technologies such as a power vent system and advanced burner design, they maximize heat transfer and minimize heat loss. This efficiency not only translates to lower operating costs but also a reduced environmental impact, making it a smart choice for businesses looking to operate sustainably.

Durability is another hallmark of State Industries' gas water heaters. Constructed from robust materials, these units are designed to withstand the rigors of daily use in a commercial environment. The tanks are often lined with glass and reinforced to prevent corrosion, enhancing the longevity of the unit. Additionally, the use of high-quality components ensures minimal maintenance and reliable operation over time, allowing businesses to focus on their core activities rather than downtime due to equipment failure.

State's Commercial Gas Water Heaters also come equipped with advanced safety features. This includes built-in temperature controls, pressure relief valves, and flame failure protection, which work together to ensure safe operation even in high-demand situations. These features provide peace of mind to operators and help meet stringent safety standards, making them suitable for any commercial setting.

Furthermore, the versatility of these water heaters is remarkable. They are available in various sizes and configurations, allowing businesses to choose a model that perfectly fits their water heating requirements. Whether for high-volume hot water needs or continuous flow applications, State's Commercial Gas Water Heaters are designed to adapt.

In conclusion, the State Industries Commercial Gas Water Heater stands out as a top choice for businesses needing reliable and efficient hot water solutions. With its focus on efficiency, durability, safety, and versatility, this water heater is built to meet the rigorous demands of the commercial market while providing value and peace of mind to operators.