Whirlpool W10100870, BFG1J5040T3NOV 5K, 6510374, 89263 Combustion Air Supply and Ventilation

Page 7

Table 1

Natural Gas Pipe Capacity Table (Cu. Ft./Hr.)

Capacity of gas pipe of different diameters and lengths in cu. ft. per hr. with pressure drop of 0.3 in. and specific gravity of 0.60 (natural gas).

Nominal Iron Pipe

 

 

 

Length of Pipe, Feet

 

Size, in. 10

20

30

40

50

60

70

80

90 100 125 150 175 200

1/2

3/4

1

1-1/4

1-1/2

13292

278190

520350

1050 730

1600 1100

73

152

285

590

890

63

130

245

500

760

56

115

215

440

670

50

105

195

400

610

46

96

180

370

560

43

90

170

350

530

40

84

160

320

490

38

79

150

305

460

34

72

130

275

410

31

64

120

250

380

28

59

110

225

350

26

55

100

210

320

After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour required for the gas input rating of the water heater. By formula:

Cu. Ft. Per Hr. Required= Gas Input of Water Heater (BTU/HR)

Heating Value of Gas (BTU/FT³)

The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT3) may be determined by consulting the local natural gas utility.

Additional tables are available in the latest edition of the "National Fuel Gas Code", ANSI Z223.1.

Combustion Air Supply and Ventilation

WARNING

Carbon Monoxide Warning Follow all the local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1 (NFPA 54)- latest edition to properly install vent system.

Failure to do so can result in death, explosion, or carbon monoxide poisoning.

IMPORTANT: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage.

The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air:

beauty shops

photo processing labs

buildings with indoor pools

water heaters installed in laundry, hobby, or craft rooms

water heaters installed near chemical storage areas

Combustion air must be free of acid-forming chemicals such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. When burned, vapors from these products form highly corrosive acid compounds. These products should not be stored or used near the water heater or air inlet.

Combustion and ventilation air requirements are determined by the location of the water heater. The water heater may be located in either an open (unconfined) area or in a confined area or small enclosure such as a closet or small room. Confined spaces are areas with less than 50 cubic feet for each 1,000 BTUH of the total input for all gas- using appliances.

7

Image 7
Contents Installation Instructions Use & Care Guide Table Of Contents Water Heater SafetyConsumer Responsibilities Installing Your GAS Water HeaterImportant Information About This Water Heater Consumer InformationSite Location Location RequirementsClearances and Accessibility Gas Pressure Gas Pressure TestingGas Supply Gas RequirementsNatural Gas Pipe Capacity Table Cu. Ft./Hr Combustion Air Supply and VentilationConfined Space Unconfined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Drafthood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveWater System Solar InstallationSpecial Applications Combination Space Heating/PotableImportant Information About Your Water Heater Installation ChecklistLighting Instructions Operating Your Water HeaterStacking Water Temperature RegulationChecking the Draft Burner FlamesDiagnostic Status Light Code Operating the Temperature Control SystemWater Temperature Adjustment Operating Modes and SettingsOperational Conditions Routine Preventive Maintenance Maintenance of Your Water HeaterDraining and Flushing Natural Gas Burner Low Nox Replacement PartsRemoving the Manifold Assembly Removing the Burner from the Manifold AssemblyExternal Inspection & Cleaning of the Flame-trap Replacing the Pilot AssemblyCleaning the Combustion Chamber and Flame-trap Testing the Igniter System Replacing the Manifold AssemblyPiezoelectric Igniter System Removing and Replacing the Gas Control Valve/Thermostat Flame Lock Safety System Operational ChecklistSlow HOT Water Pilot Light Troubleshooting Chart Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations

W10100870, 89263, SG1J4040T3NOV 5K, BFG1J5040T3NOV 5K, 6510374 specifications

Whirlpool is a leading name in the home appliances industry, known for its innovative technology and user-friendly designs. Among its extensive product range, various models stand out for their unique features and capabilities. Such models include the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870, each designed to enhance functionality and convenience in kitchen environments and more.

The Whirlpool 6510374 is a versatile appliance often used for its high efficiency and reliable performance. It includes features like adjustable shelves, which provide flexibility in arranging your items to maximize storage space. The smart cooling technology ensures uniform cooling throughout the unit, preserving the freshness of perishables for extended periods.

Next, the BFG1J5040T3NOV 5K offers advanced features tailored for energy efficiency. Its high efficiency compressor not only provides optimal cooling but also helps consumers save on energy bills. Furthermore, it includes a user-friendly digital display that allows for precise temperature control and easy monitoring, catering to the needs of modern families.

The SG1J4040T3NOV 5K model enhances user convenience with features such as a frost-free design, which eliminates the need for manual defrosting, saving both time and effort. This feature, combined with its spacious interior, makes it highly desirable for storing large quantities of food.

Model 89263 focuses on ease of use and maintenance. With its intuitive interface and durable construction, this model stands out in terms of reliability. Its robust design ensures longevity while maintaining performance, making it a dependable choice for families.

Lastly, the W10100870 offers unique characteristics centered around connectivity and technology. Equipped with smart features, it allows users to connect their devices and control settings remotely. This model exemplifies the shift towards smart home technology, creating a seamless integration of appliances into daily life.

In conclusion, the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870 each present an array of features that enhance functionality, efficiency, and user experience. Whirlpool continues to push boundaries in appliance design, ensuring that each model is a safe, reliable, and smart choice for consumers worldwide. These models reflect the brand’s commitment to quality, innovation, and customer satisfaction, making them an essential part of any modern kitchen.