Whirlpool 6510374, BFG1J5040T3NOV 5K, W10100870 Chimney Connection, Vertical Exhaust Gas Vent

Page 11

Chimney Connection

IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

The connector must be installed above the extreme bottom of the chimney to prevent potentially blocking the flue gases.

The connector must be firmly attached and sealed to prevent it from falling out.

To aid in removing the connector, a thimble or slip joint may be used.

The connector must not extend beyond the inner edge of the chimney as it may restrict the space between it and the opposite wall of the chimney (Figure 10).

Do not terminate the vent connector in a chimney that has not been certified for this purpose. Some local codes may prohibit the termination of vent connectors in a masonry chimney.

Vertical Exhaust Gas Vent

Vertical exhaust gas vents must be installed with U.L. listed type B vent pipe according to the vent manufacturer’s instructions and the terms of its listing.

It must be connected to the water heater’s drafthood by a listed vent connector or by directly originating at the drafthood opening.

Vertical gas vents must terminate with a listed cap or other roof assembly and be installed according to their manufacturer’s instructions.

Gas vents must be supported to prevent damage, joint separation, and maintain clearances to combustible materials (Figures 11 and 12).

IMPORTANT: This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases.

An unused chimney flue or masonry enclosure may be used as a passageway for the installation of a gas vent (Figure 12).

Common (combined) venting is allowable with vertical type B vent systems and lined masonry chimneys.

Figures 10-12 are examples of vent pipe system installations and may or may not be typical for your specific application. Consult the “National Fuel Gas Code”, NFPA 54, ANSI Z223.1-latest edition and the guidelines set forth by prevailing local codes.

Listed Lined

Chimney

2 ft. minimum above any

object within10 ft. horizontally

3 ft. minimum

*

Slope up

1/4 in.

per ft.

minimum

2 ft. minimum above any

3 ft. minimum object within10 ft. horizontally

*

**

Vent connector slope up

1/4 in. per ft.

minimum

5 in. minimum

**

 

 

 

 

 

*

Slope up 1/4 in. per ft. minimum

*Maintain vent pipe clearance requirements to local, state and/or the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

**NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances states that these chimneys are intended to be installed in accordance with the installation instructions provided with each chimney support assembly. Minimum air space clearance to combustible materials should be maintained as marked on the chimney sections.

11

Image 11
Contents Installation Instructions Use & Care Guide Table Of Contents Water Heater SafetyConsumer Responsibilities Installing Your GAS Water HeaterImportant Information About This Water Heater Consumer InformationSite Location Location RequirementsClearances and Accessibility Gas Pressure Gas Pressure TestingGas Supply Gas RequirementsNatural Gas Pipe Capacity Table Cu. Ft./Hr Combustion Air Supply and VentilationAll Air from Inside the Building Unconfined SpaceConfined Space Louvers and Grilles All Air from OutdoorsVent Pipe Size Drafthood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveWater System Solar InstallationSpecial Applications Combination Space Heating/PotableImportant Information About Your Water Heater Installation ChecklistLighting Instructions Operating Your Water HeaterStacking Water Temperature RegulationChecking the Draft Burner FlamesDiagnostic Status Light Code Operating the Temperature Control SystemWater Temperature Adjustment Operating Modes and SettingsOperational Conditions Draining and Flushing Maintenance of Your Water HeaterRoutine Preventive Maintenance Natural Gas Burner Low Nox Replacement PartsRemoving the Manifold Assembly Removing the Burner from the Manifold AssemblyCleaning the Combustion Chamber and Flame-trap Replacing the Pilot AssemblyExternal Inspection & Cleaning of the Flame-trap Piezoelectric Igniter System Replacing the Manifold AssemblyTesting the Igniter System Removing and Replacing the Gas Control Valve/Thermostat Flame Lock Safety System Operational ChecklistSlow HOT Water Pilot Light Troubleshooting Chart Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations

W10100870, 89263, SG1J4040T3NOV 5K, BFG1J5040T3NOV 5K, 6510374 specifications

Whirlpool is a leading name in the home appliances industry, known for its innovative technology and user-friendly designs. Among its extensive product range, various models stand out for their unique features and capabilities. Such models include the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870, each designed to enhance functionality and convenience in kitchen environments and more.

The Whirlpool 6510374 is a versatile appliance often used for its high efficiency and reliable performance. It includes features like adjustable shelves, which provide flexibility in arranging your items to maximize storage space. The smart cooling technology ensures uniform cooling throughout the unit, preserving the freshness of perishables for extended periods.

Next, the BFG1J5040T3NOV 5K offers advanced features tailored for energy efficiency. Its high efficiency compressor not only provides optimal cooling but also helps consumers save on energy bills. Furthermore, it includes a user-friendly digital display that allows for precise temperature control and easy monitoring, catering to the needs of modern families.

The SG1J4040T3NOV 5K model enhances user convenience with features such as a frost-free design, which eliminates the need for manual defrosting, saving both time and effort. This feature, combined with its spacious interior, makes it highly desirable for storing large quantities of food.

Model 89263 focuses on ease of use and maintenance. With its intuitive interface and durable construction, this model stands out in terms of reliability. Its robust design ensures longevity while maintaining performance, making it a dependable choice for families.

Lastly, the W10100870 offers unique characteristics centered around connectivity and technology. Equipped with smart features, it allows users to connect their devices and control settings remotely. This model exemplifies the shift towards smart home technology, creating a seamless integration of appliances into daily life.

In conclusion, the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870 each present an array of features that enhance functionality, efficiency, and user experience. Whirlpool continues to push boundaries in appliance design, ensuring that each model is a safe, reliable, and smart choice for consumers worldwide. These models reflect the brand’s commitment to quality, innovation, and customer satisfaction, making them an essential part of any modern kitchen.